Alemite 9916-A Скачать руководство пользователя страница 9

Low-Pressure Transfer Pump

SER 9916-A

Alemite LLC

9

Revision (2-10)

Operation

WARNING

Do not exceed the lowest pressure rating

of any component in the system.

Never point a control valve at any portion of your
body or another person. Lubricant discharged at
high velocity can penetrate the skin and cause
severe injury. Should any fluid appear to puncture
the skin, get medical care immediately.

Ensure all components are in operable condition.
Replace any suspect parts prior to operation.
Personal injury can occur. 

  1. Make sure air pressure at the regulator reads zero.

  2. Slowly supply air pressure [not to exceed 25 psi 

(1.7 Bars] to the pump’s motor.
• The pump assembly should cycle.

If the pump assembly does not cycle, refer to the 

Troubleshooting Chart 

for details.

With air pressure at zero:

  3. Connect a product hose to the pump’s material outlet. 

• Direct the hose into an appropriate container.

  4. Place the pump in the product to be dispensed.

  5. Slowly supply air pressure to the pump’s motor.

  6. Allow the pump to cycle slowly until the system and 

product is free of air.

If the pump assembly does not prime, refer to the 

Troubleshooting Chart 

for details.

WARNING

Should leakage occur anywhere within the

system, disconnect air to the motor. Personal
injury can occur.

With air pressure at zero:

  7. Attach a control valve to the outlet hose of the pump.

  8. Slowly supply 35 psi (2.4 Bars] air pressure to the 

pump’s motor.

  9. Operate the control valve into a container.

10. Allow the pump to cycle until the system and product 

is once again free of air.

11. Shut off the control valve.

12. Set the air pressure to 100 psi (6.9 Bar).

13. Visually inspect the pump for external leaks.

• The pump should not cycle.

If the pump does not stall, refer to the 

Troubleshooting Chart 

for details.

14. Check the motor for air leakage.

If the motor leaks, refer to the

 Troubleshooting Chart 

in the

 Air Motor Service Guide 

for details.

Installation

Additional items that should be incorporated into the 

air piping systems are listed in 

Table 4

.

Part Number

Description

5604-2

Moisture Separator

7604-B

Regulator and Gauge

Table 4

Air Line Components

Содержание 9916-A

Страница 1: ...to original containers or bulk tanks that have a 2 NPTF bung fitting The required length downtube screws directly into the 1 1 2 NPTF female threads in the valve body As an alternative the pump can al...

Страница 2: ...SER 9916 A Low Pressure Transfer Pump Revision 2 10 2 Alemite LLC Figure 2 Low Pressure Transfer Pump Model 9916 A Exploded View...

Страница 3: ...339489 Rod Tie 8 171700 56 32 13 339412 Keeper 4 172190 24 17 14 Coupling 4 172190 26 19 15 339495 Body Outlet 1 319391 4 16 320531 Bushing 3 4 NPTF m x 1 2 NPTF f 1 320531 16 17 Seal 1 2 ID x 3 4 OD...

Страница 4: ...ute X axis to air consumption in cubic feet liters per minute right Y axis and to material discharge pressure in psi Bars left Y axis Extension Description Drum Tank 16 Gallon 55 Gallon 250 Gallon Ben...

Страница 5: ...Washers 2 that secure Air Motor Assembly 3 to the pump assembly NOTE The bottom end cap of the Air Motor Assembly remains on the pump tube during the next procedure 3 With a side to side motion pull...

Страница 6: ...and Fluid Piston Assembly 17 Remove the Rod with attached components from the Outlet Body 18 Remove lower Nut 27 that secures Fluid Piston 24 to the Rod NOTE Place an appropriate size punch or other s...

Страница 7: ...or other suitable tool into the hole of the Rod CAUTION Install the Rod assembly into the Body with a twisting motion Use care not to damage the Seals 8 Install the Rod assembly into the bottom of th...

Страница 8: ...e Ring to the pump assembly Torque the Nuts in a crisscross pattern to 60 to 70 inch pounds 6 8 7 9 Nm Attach Air Motor to Pump Assembly CAUTION Install the RAM Air Motor Assembly with care Damage to...

Страница 9: ...air pressure to the pump s motor 6 Allow the pump to cycle slowly until the system and product is free of air If the pump assembly does not prime refer to the Troubleshooting Chart for details WARNIN...

Страница 10: ...Body 15 1 Damaged Seal 19 2 Damaged Rod 22 1 Replace Seal 19 2 Inspect Rod 22 and replace as necessary Product leakage visible at top of Cylinder 28 1 Nuts 2 not sufficiently tight 2 Damaged O Ring 1...

Отзывы: