![Alemite 7716-D1 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/alemite/7716-d1/7716-d1_service-manual_2893723010.webp)
SER 7716-D1
High-Pressure Measuring Control Valve
Revision (11-95)
10
Alemite Corporation
D
D
Lever Depressed
Discharge
Pressure
Chamber A
Chamber B
Lever Released
Discharge
Chamber A
Product Flow
With the lever released and the system pressurized, product enters Port B
and fills Chamber B.
Initial Fill
Lever Depresssed
When the lever is depressed, the slide valve moves to allow product
to enter Port A and fill Chamber A. At the same time the slide valve
aligns Port B with Port D. This allows product to flow
from Chamber B via Port B and into Port D to discharge.
Lever Released
When the lever is released, the slide valve moves to allow product to enter Port B
and fill Chamber B once again. At the same time the slide valve aligns Port A with Port D.
Product from Chamber A flows via Port A into Port D to discharge.
Pressure
Chamber B
Pressure
Discharge
Ports
Ports
A
B
A
B
Figure 6
High-Pressure Measuring Control Valve Model 7716-D1 - Section View of Valve Body