background image

SER 6713-4

High-Pressure Bucket Pump

Revision (2-02)

2

Alemite Corporation

Model Assembly

Refer to Figure 2-A for the assembly of the 

components that are shipped loose.

Filling

The pump’s container can be filled from a transfer 

pump or manually.

NOTE: The three steps that follow consider
the pump without a follower plate.

Transfer Pump Loading

NOTE: Refer to Figure 2-A for component
identification on the following procedures.

  1. Slide the fill-hole cover away from the pump.

  2. Insert the hose from the transfer pump into the 

opening.
• Make sure the hose reaches the bottom of Container 

Assembly (7) or the surface of the product.

IMPORTANT: Keep the end of the hose (or
wand) just underneath the surface of the
grease. This prevents air from mixing with
the product during the fill process.

  3. Fill the Container within 2-inches (5 cm) from the top.

Manual Loading (Paddle)

  4. Loosen Knobs (3) from the bolts on Container 

Assembly (7).
• Swing the bolts away from Cover Assembly (9).

CAUTION

Point the bottom of the pump tube upward. Pre-
vent contamination from foreign material. Damage
to components can occur.

  5. Remove the cover and pump assembly from the 

Container Assembly.

  6.  Fill the Container within 2-inches (5 cm) from the top.

• Do not allow air to be entrapped during the filling 

process.

  7. Place the optional follower plate onto the top of the 

product.
• With a wobbling motion, eliminate any air that may 

be trapped underneath the follower. Force the 
product through the hole in the center of the plate.

  8. Position the cover and pump tube assembly into the 

follower plate and fit the Cover onto the Container.

  9. Secure the Cover to the Container with the Knobs.

Operation

WARNING

Do not exceed the lowest pressure rating of

any component in the system.

Ensure all components are in operable condition.
Replace any suspect parts prior to operation.
Personal injury can occur. 

Priming the Pump

NOTE: Refer to Figure 2-B for component
identification on the following procedures.

  1. Turn Bleed Valve Screw (26) counterclockwise to open.

  2. Make sure Pressure-Relief Valve Screw (29) is closed.

  3. Cycle the Lever until product causes the cycling of the 

Lever to stiffen.

If the pump assembly does not prime, refer to the 

Troubleshooting Chart for details.

  4. Close the Bleed Valve Screw until it seats.

Dispensing

  5. Wipe the end of the coupler and the fitting to be 

lubricated with a clean cloth.

  6. Attach the coupler to the lubrication fitting.

  7. Operate the lever until the proper amount of lubricant is 

dispensed.

NOTE: Certain applications can create exces-
sive back-pressure at the fitting that inhibits
the removal of the coupler. Should this occur:

  8. Turn Pressure-Relief Valve Screw (29

counterclockwise to open.
• This allows the product within the delivery hose to 

return to the Container.

  9. Remove the coupler from the fitting and close the 

Pressure-Relief Valve Screw.

NOTE: Should the Lever be stopped in the
upward position:

10. Turn Bleed Valve Screw (26) counterclockwise to open.

• This allows the Lever to be pushed downward without 

product discharge.

Содержание 6713-4

Страница 1: ...3 4 Description The major components of model 6713 4 bucket pump assembly consist of a hand operated two stage pumping mechanism with bleed valve and pressure relief valve 30 pound 13 6 kg capacity ta...

Страница 2: ...he follower Force the product through the hole in the center of the plate 8 Position the cover and pump tube assembly into the follower plate and fit the Cover onto the Container 9 Secure the Cover to...

Страница 3: ...embly 1 See Figure 2 B 12369 6 2 Grip Handle 1 77650 5 3 303087 Knob 3 77736 8 4 Pin Cotter 3 172212 1 4 5 Nut 6 303087 3 6 Washer Lock 6 308725 B4 7 7 308725 B4 Container Assembly w o Decal 1 308726...

Страница 4: ...SER 6713 4 High Pressure Bucket Pump Revision 2 02 4 Alemite Corporation Figure 2 B Pump Assembly Model 310750 4 Exploded View...

Страница 5: ...0522 Plug Pipe 1 4 NPTF m 1 305336 25 24 322546 Body Adapter 1 308707 2 20 25 Handle 1 308708 32 26 47123 Screw Bleed Valve 1 308709 35 322549 Screw Assembly Pressure Relief Valve 1 308710 38 27 17070...

Страница 6: ...lt 39 that secures the Toggle to the Handle Assembly as needed 8 Remove Cotter Pin 17 that secures the Adapter to Primer Rod 33 Unscrew the Adapter from the Primer Rod NOTE Grip Priming Plunger 34 to...

Страница 7: ...Pump Tube NOTE Refer to Figure 3 for a section view of the pump tube assembly 1 Install and seat both lubricated O Rings 19 into Body 20 CAUTION Install Plunger 18 and Primer Rod 33 with care Damage...

Страница 8: ...ed Check Valve Assembly 15 Install Pressure Relief Valve Screw 29 into Bushing 28 16 Install Retaining Ring 27 that secures the Valve Screw to the Bushing 17 Screw the Pressure Relief Valve Screw Asse...

Страница 9: ...e Adapter and the Handle Assembly See Figure 2 B 28 Install Toggle Bolt 11 Lock Washers 12 and Nut 13 that secures the Handle Assembly to the Adapters Tighten the Nut securely 29 Install upper Toggle...

Страница 10: ...material between Ball 46 and Ball Seat 44 in Check Valve Assembly 22 2 Worn or damaged Ball 46 and or Ball Seat 44 1 Disassemble Check Valve Assembly 22 and eliminate foreign material 2 Use Repair Kit...

Отзывы: