AC-2000-Spring limit tch (see Fig.11) 

To ensure safety, it is recommended to install limit devices at both ends of the gate to 
prevent the gate from sliding out of the rails. The rails must be installed horizontally. 
The spring limit switch and blocks are used to control the position of the gate. 
When the block is installed, release the gear clutch with the key and push the sliding gate 
manually to pre-determine the position, fix the block bracket to the gate and then tighten 
the gear clutch with the key. Moving the gate electrically, adjust the block bracket to the 
proper position until the position of the opening and closing meet the requirement. 

Release key

Gate operator 

Gate 

Spring limit 

switch and block

Block bracket

Fig.11 AC-2000 

6. Connect the wires

Make sure that the power is OFF before making any electrical connections. Remove the cover 
of the control box, perform the wiring and replace the cover again. (Refer to Fig.12)

Fig.12

7. Adjustment 

Check the power supply, grounding and wiring before running the device. 
Release the clutch with the key to determine whether or not the gate can be moved manually. 
If everything is in good working order, engage the clutch with the key. 
When engage the clutch with the key, be sure to close completely to prevent from damage. 
Switch on the power and run the operator to ensure that the gate is sliding smoothly. 
Adjust  magnet  or  block  position  until  the  gate  opened  and  closed  properly  at  the  limited 
positions.

Содержание LOCKMASTER AC2000

Страница 1: ...Gate1Access LLC P O box 121776 Clermont Fl 34712 sales Gatemotors com www Gatemotors com 2011 2012 Aleko Lockmaster All Rights Reserved ALEKO AC2000 SLIDE GATE OPENER LOCKMASTER L110C GATE OPENER...

Страница 2: ...AC 2000 SLIDING GATE OPERATOR 1 OUTLINE 1 Important safety information 3 2 Main functions 3 3 Technical parameters 3 4 Packing list 3 5 Installation 5 6 Connect the wires 9 7 Adjustment 9 8 Maintenan...

Страница 3: ...sliding gate it is capable of overwork in short time When overloading it has electrical and mechanical double protections to ensure operating safety In case of power failure a release key allows to lo...

Страница 4: ...se of various tools shown below Other tools may be required as needed for the installation of the concrete pad and electrical connection Table 3 Required Tools for Installation Screwdriver Tape Measur...

Страница 5: ...y t i t n a u Q m e t I o N 1 Gate operator 1 2 Release key 2 3 Operator base spare accessory 1 4 Tighten bar 2 5 Block bracket 2 6 Sprocket cover 1 7 Screw for mounting driven sprocket bracket M8X16...

Страница 6: ...Installation The AC 2000 Chain driven Gate Operator operates by forcing a straight piece of chain This length of chain is extended between two chain brackets located at opposite ends of the gate The...

Страница 7: ...oncrete pad The base unit of the gate operator requires a concrete pad in order to maintain proper stability The concrete pad should be approximately 300mm x 260mm x120mm deep in order to provide for...

Страница 8: ...sher 6 Gate Square frame Fig 6 If the gate is of round frame style use the round bolts shown Round bolt L bracket Plain washer 8 Spring washer 8 Nut M8 Chain bolt Master link Nut M6 Spring washer 6 Pl...

Страница 9: ...is for open position and upper bracket is for close position Finally adjust the magnet to the proper position by moving the gate with the motor The magnet should be 10 15mm away from the magnetic limi...

Страница 10: ...pening and closing meet the requirement Release key Gate operator Gate Spring limit switch and block Block bracket Fig 11 AC 2000 6 Connect the wires Make sure that the power is OFF before making any...

Страница 11: ...IP Switch 1 Limit switch NC normally closed or NO normally open DIP Switch 1 ON NO OFF NC This mode enables user to set the board to work with motor with NC or NO limit switch NOTE Factory default set...

Страница 12: ...inside of the property where the opener is installed DIP Switch 5 OFF Opens to the right DIP Switch 5 ON Opens to the left Note If opening is to the left the Limit Switch wires on the control board y...

Страница 13: ...8 ON Blue Button is Working OFF Blue Button is Not Working 2 Potentiometers The left potentiometer is to adjust the CLOSE stall force of the gate opener The right Potentiometer is used to adjust the...

Страница 14: ...meter in counter clockwise direction Turning the stall force potentiometer toward to Light position to increase the reversing sensitivity Note 1 If the sensitivity setting is too higher the gate will...

Страница 15: ...Residential Sliding Gate Operator AC1400 Optional Equipment Installation Procedures O O O O O O O O O O O O Blue Brown Black White Green Brown Red Black 13...

Страница 16: ...rminal blocks The electric component on the control board such as Q2 Q91 or Q92 may be damaged Replace the electric component Q2 Q91 or Q92 BTA16 600 or replace the board The gate will not open or clo...

Страница 17: ...2005 2009 Aleko LockMaster All Rights Reserved sales Gatemotors com www Gatemotors com...

Отзывы: