36
5.2 Display lighting
On adapter power:
• Repeatedly press the SNOOZE/LIGHT button at the rear of the weather station to set the display
lighting to full intensity, half intensity or off.
• The selected setting will remain in the memory until you press the SNOOZE/LIGHT button gain
On battery power only:
•
Briefly press the SNOOZE/LIGHT button at the rear of the weather station to switch the display lighting
on at full intensity.
•
To save battery power, the display lighting switches off after 10 seconds
6. SPECIFICATIONS
Indoor temperature
range:
0°C to 50°C / 14°F to 122°F
accuracy:
0°C to 40°C: ±1°C
40°C to 50°C: ±2°C
Outdoor temperature
range:
-20°C to 70°C / -4°F to 149°F
accuracy:
0°C to 40°C: ±1°C
-20°C to 0°C & 40°C to 70°C: ±2°C
Indoor humidity
range:
20%RH to 95%RH
accuracy:
40-80%: ±5%
30-40% & 80-90%: ±8%
20-30% & 90-95%: not measured
Outdoor humidity
range:
20%RH to 95%RH
accuracy:
40-80%: ±5%
30-40% & 80-90%: ±8%
20-30% & 90-95%: not measured
Air pressure
range:
600 hPa/mb to 1100 hPa/mb / 17.72 inHg to 32.48 inHg
accuracy:
±5 hPa
7. CLEANING AND MAINTENANCE
Always remove the adapter from the wall socket before cleaning the indoor unit. If you make sure to
install 2 backup batteries at the rear of the unit, you don’t have to worry about losing any data.
Clean the indoor unit with a moist cloth. Never use aggressive or abrasive cleaning products. The out-
door unit may also be wiped down with a moist cloth.
The weather station requires no maintenance. However, we advise you to replace the battery at least
once a year.