Alecto SMART-SMOKE10 Скачать руководство пользователя страница 9

Do not place here

Place near here

Minimum distance

USING, REGISTERING, TESTING AND MAINTENANCE:

Using: 

A smoke detector is in operation when the batteries are installed. Make sure the red tab is turned in. This is held in place by the 2x AA 

batteries. Only when the batteries are installed will the unit be able to be placed on the ceiling plate. When one of the detectors enters the smoke or 
smoke, the alarm will sound. If the smoke or walm disappears, the alarm will automatically stop. To connect to the SMART-BRIDGE10 and TUYA 
app, you must first log on the device.  As soon as a smoke detector goes off, it will also send a signal to the app, which will indicate whether a 
programmed scenario has started.

Connecting: 

To connect to the SMART-BRIDGE10 and TUYA APP, refer to the registration manual

Time-out function:

This function will disable the alarm for approximately 10 minutes. This function can be activated by pressing the button once. The indicator light will 
light up ± every 8 seconds to indicate that the sound has been temporarily muted. After 10 minutes, the alarm will be reactivated. 

Test: 

The alarm is very loud (>85dB). We recommend using hearing protection when testing the smoke detectors. By pressing the test button on the 

SMART-SMOKE10 the alarm can be tested. 
Press the test button for at least 2 seconds. Operation is correct for 2 or 3 signal tones. Then the alarm is still working correctly. 
The App will now receive a notification. 
If a detector’s test does not work, check the battery. If it does not work with a new battery, replace the appropriate Smoke Alarm.

The test function does not work if the time-out function is enabled. Check the detectors every week. In alarm status, the smoke detectors generate at 
least 85dB(A) of sound pressure. Do not test the smoke detectors with candles, open flames, cigarettes, or the like.

ATTENTION:

If there are questions about the cause of an ALARM, assume that the alarm is caused by a fire and immediately evacuate the home.

Keep smoke detectors out of the reach of children.

During construction and renovation work, protect the smoke detectors from dust. Without protection, the smoke detectors lose their functionality.

Maintenance: 

The smoke detector is maintenance-free. In very dusty rooms they may be cleaned by vacuum. 

Plan an escape route: 

• 

Make a map and mark all locations of doors and windows and a possible escape route. Note that you may need an escape ladder on high floors.

• 

Ensure everyone in the house knows the sound the smoke alarms produce and regularly practice use of the escape route.

• 

Leave the house immediately according to the plan when hearing the alarm. Every second counts: so respond quickly. If you do not notice smoke or heat, 
check if everyone in the house is in a secure location.

• 

Do not open any doors without feeling wether the door is warm or if there is smoke coming from underneath the doors. If it is, do not open that 
door. If the door is cold, put your shoulder firmly against the door and open it a small amount to check for any heat or smoke first. 

If there is much smoke, keep low and take shallow breaths, preferably through a moist towel. Call the fire department as soon as you are safe 
outside.  
 

Replacing the batteries: 

The detectors are supplied using 2x AA batteries. Only use the recommended types:  

Energizer E91

Gold Peak Group GP15A

Raymax LR6

 Under normal conditions the battery will last at least one year. If it is about to need replacement, the smoke detector will make a chirping sound every 
40 seconds for at least 30 days. Pay attention to the polarity when replacing batteries. Test the detector after every battery replacement. If the 
smoke detector does not function, please contact your supplier.

Environment: 

Do not throw away used batteries, but recycle them using your local chemical depot.

Product may not be thrown out as normal waste, but must be recycled as electrical waste.

Connect / Test / Time-out-button

Document NO.: RD-558-39-001

Version: D 2015.11.10

- 6 -

Holes of ceiling or wall

Two screws (3*25mm)

bracket

plastic plugs

Alarm body

Diagram 3

Document NO.: RD-558-39-001

Version: D 2015.11.10

- 6 -

Holes of ceiling or wall

Two screws (3*25mm)

bracket

plastic plugs

Alarm body

Diagram 3

Max

30M

Содержание SMART-SMOKE10

Страница 1: ...e omgeving D tecteur de fum e pour l usage dans l entourage domestique Rauchmelder zum Gebrauch im Heimbereich Smoke alarm for domestic use Detector de humo para uso en el hogar Koppelbaar met SMART B...

Страница 2: ...ur staat die eventueel brand zou kunnen veroorzaken een melder Rook hitte en verbrandingsproducten zullen rst omhoog naar het plafond trekken Daarna trekken de rook hitte en verbrandingsproducten hori...

Страница 3: ...ffige ruimte dient de sensor kamer van de SMART SMOKE10 met een stofzuiger stofvrij worden gemaakt CRE EREN EN PLANNEN VAN EEN VLUCHTROUTE Maak een plattegrond en geef daarop alle deuren en ramen aan...

Страница 4: ...ent qui pourrait causer un incendie La fum e la chaleur et les produits de combustion se dirigent d abord vers le plafond Ensuite la fum e la chaleur et les produits de combustion migrent horizontalem...

Страница 5: ...marquez toutes les portes et les fen tres d terminez imm diatement une route de secours Il est possible qu il faille une corde ou une chelle de secours pr s des fen tres sur les tages plus hautes Fami...

Страница 6: ...m geraucht wird oder in dem sich Ger te befinden die einen Brand verursachen k nnen Rauch W rme und Verbrennungsprodukte werden zun chst an die Decke gezogen Danach wandern die Rauch W rme und Verbren...

Страница 7: ...enn Sie in einer h heren Etage wohnen k nnen Fenster Rettungsleiter oder Seile sehr wichtig sein Machen Sie jeden der in Ihrem Haus wohnt mit dem Signalton des Rauchmelders vertraut und ben Sie das Ve...

Страница 8: ...d cause a fire Smoke heat and combustion products will first pull up to the ceiling After that the smoke heat and combustion products will continue horizontally If you mount the detector to the ceilin...

Страница 9: ...of the reach of children During construction and renovation work protect the smoke detectors from dust Without protection the smoke detectors lose their functionality Maintenance The smoke detector i...

Страница 10: ...ar un incendio El humo el calor y los productos de combusti n llegar n primero al techo Despu s de esto el humo el calor y los productos de combusti n continuar n horizontalmente Si monta el detector...

Страница 11: ...CREACI N Y PLANES DE ESCAPE Haga un plan de evacuaci n y dibujelo en todas las puertas y ve ntanas Seleccione la ruta de escape inmediatamente Si usted vive en un piso alto escalera de rescate o cuer...

Страница 12: ...SMART SMOKE10 est conforme la directive 2014 53 UE Le texte complet de la d claration UE de conformit est disponible l adresse internet suivante http DOC hesdo com SMART SMOKE10 DOC pdf BEREINSTIMMUN...

Отзывы: