1.   Before checking or refilling oil, be sure the 

generator is put on a stable and level surface, 

ensuring the engine has been switched OFF.   

When filling with oil you can lift the generator 

approximately 100 mm at the front (Fig G),  

however the generator must be sitting flat back on 

its feet when checking the level of oil using the oil 

filler cap/dipstick (12).

   Make sure you check the capacity of fuel tank 

before checking the oil level. The fuel tank 

(26) should be less than 50% full when the 

generator is tilted by 100mm to fill the oil 

reservoir, or fully drained if the generator is 

tilted more than 100mm.

2.   Remove the oil filler cap/dipstick (12) 

by rotating the cap in an anti-clockwise 

direction, and wipe all oil residue off the oil 

filler cap/dipstick (12) with a clean rag.  

Re insert the oil filler cap/dipstick (12) and  

thread the cap fully in position.

   Then remove the oil filler cap/dipstick (12) by rotating in an anti clockwise 

direction and view the oil level on the oil filler cap/dipstick (12).

3.   If the oil level is close to or below the lower level line, refill using the supplied 

oil bottle (32) with 4 stroke oil to the upper level line (Fig H).

   Do not use the generator when the oil level is close to the low level.  Fill the 

oil tank before use each time.

4.   If the oil is contaminated or has discoloured, ensure you change the oil.  

Replace the oil filler cap/dipstick (12). DO NOT start the generator with the 

oil Filler cap/dipstick (12) not firmly replaced.

   NOTE: This engine is fitted with a  low oil indicator light (4).  If the oil level 

is too low the engine will stop operating or the engine will not start. It is 

advised to check the oil level each time the generator is used and fill to the 

upper mark on the oil filler cap/dipstick (12) by the above method.   

Do NOT over fill.

Preparation Information

Preparation Information

WARNING.

•   Do not refill fuel tank (26) while engine is running or is hot.
•    Check to ensure that the fuel drain (10) has been tightened and that fuel is 

not leaking.

•    Be careful not to admit dust, dirt, water or other foreign objects into the fuel.
•   Wipe off spilt fuel thoroughly before starting engine.
•    Ensure you DO NOT fuel the generator in close proximity to any open 

flames, lit cigarettes, or hot objects.

•    The generator should also be located in an open area with fresh air and NOT 

in a confined area.

WARNING: Ensure the engine is switched off while undertaking  

this task.

1.   Remove the fuel tank cap (27) by rotating in an anticlockwise direction. 
2.   Remove the fuel tank inlet filter (24) and ensure it is clean and free of debris.   

Check the level of fuel is sufficient.

3.   If the fuel tank inlet filter (24) was removed to check the fuel level, ensure it 

is replaced back before adding fuel.

4.   To add fuel, pour the unleaded fuel from an approved fuel container into the 

fuel tank (26). As fuel expands, DO NOT FILL to the lip of the tank. Maximum 

fill is to the top of the fuel tank inlet filter (24) rim. 

5. Replace fuel tank cap (27) turning in a clockwise direction to lock.

Filling and checking the Engine oil

The engine of this generator is NOT filled with oil when unpacked.
Prior to starting the engine ensure the oil tank is filled with SAE 10W-30 

4 stroke oil. For the first time fill the engine should be filled with 550ml  

(+/-10%) of SAE 10W-30 oil. We recommend GARDENLINE® Full Synthetic  

4 Stroke Oil.
NOTE: Damage to the engine is not covered under warranty if the engine is 

run with insufficient oil.  
NOTE: Ensure the fuel tank cap (27) is secure before attempting to add oil.

G.

H.

UPPER

MARK

LOWER

MARK

Содержание Workzone Titanium+ 62007

Страница 1: ...OR WITH PURE SINEWAVE User Manual Product Info https help tools Read all safety warnings and all instructions thoroughly before operating this product Ensure you keep your manual in a safe place for future reference IM Ed7 09 2018 ...

Страница 2: ...Description of symbols 3 General safety warnings 4 Additional Safety Rules for Petrol Products 6 Safety Risk 8 Risk of electrocution and fire 8 Risk of fire 9 Risk of injury and property damage when transporting generator 9 Risk of breathing inhalation hazard 9 Risk of unsafe operation 10 Risk of hot surfaces 10 Risk of moving parts 10 Risk from lifting 10 Assembly 11 Parts List 12 Intended use of...

Страница 3: ...sensitive equipment like computers sound systems televisions microwaves etc it is highly recommended to have a surge protector connected to the generator NOTE This petrol Generator is NOT suitable for Marine applications and should never be used on board water craft Continuous off the grid power Contents of carton 1 x Inverter Generator 1 x Instruction Manual 1 x Warranty Card details 1 x Quick St...

Страница 4: ...g power tools with your finger on the switch or energising power tools that have the switch on invites accidents d Remove any adjusting key or wrench before turning the power tool on A wrench or key left attached to a rotating part of the power tool may result in personal injuries e Do not overreach Keep proper footing and balance at all times This enables better control of the power tool in unexp...

Страница 5: ...e oil Any extension cable should be of heavy duty 3 core and rated to 15A and suitable for outdoor applications Never fill fuel tank indoors Never fill fuel tank when engine is running or hot Do not smoke when filling fuel tank NEVER REFUEL WHEN THE GENERATOR IS RUNNING Switch the generator to the off position prior to removing the fuel cap and refuelling Not suitable for ethanol fuels Engine spee...

Страница 6: ...ettes sparks fires or other hot objects can cause fuel or fuel vapours to ignite Add fuel to tank in well ventilated area Make sure there are no sources of ignition near the generator Improper storage of fuel Improperly stored fuel could lead to accidental ignition Fuel improperly secured could get into the hands of children or other unqualified persons Store fuel in an approved container designed...

Страница 7: ...moving parts Hazard What could happen How to prevent it Contact with moving parts can result in serious injury The generator contains parts which rotate at high speed during operation These parts are covered by guarding to prevent injury Never operate generator with guarding or cover plates removed Avoid wearing loose fitting clothing or jewellery which could be caught by moving parts Risk from li...

Страница 8: ...ndicator light 6 Power Supply indicator light 7 Muffler 8 Exhaust spark arrestor 9 AC sockets X2 10 Fuel drain 11 Control panel 12 Oil Filler cap dipstick 13 Oil tank 14 Ground frame terminal 15 Recoil starter 16 Choke lever 17 Air filter cover 18 Air Filter 19 Spark plug lead cover 20 Spark Plug 21 FuelTap outlet 22 Fuel extension filter 23 Fuel tap lever 24 Fuel tank inlet filter 25 Feet x4 26 F...

Страница 9: ...ectrical appliance s including televisions computers laptops caravans etc It comes fitted with 2 x 240V AC outlets giving you the ability to run 2 x electrical appliances at the one time as long as the combination of the maximum rating of each appliance does not exceed the maximum rated power of the generator The maximum operational combination on this generator is 2000W For a short period to aid ...

Страница 10: ...e is overheated caused by high temperature Preparation information Preparation Information c Flashing 3 times indicates overload protection caused by an excessive electrical overload d Flashing 4 times indicates there is an electrical problem most likely caused by a short circuit In any of the above instances when the red load status indicator light 5 turns on the power supply to the control panel...

Страница 11: ...oil indicator light 4 If the oil level is too low the engine will stop operating or the engine will not start It is advised to check the oil level each time the generator is used and fill to the upper mark on the oil filler cap dipstick 12 by the above method Do NOT over fill Preparation Information Preparation Information WARNING Do not refill fuel tank 26 while engine is running or is hot Check ...

Страница 12: ...f the generator ensuring it is in front of the oil filler cap dipstick 12 area Commence removing the oil filler cap dipstick 12 by rotating in an anti clockwise direction to remove so that the oil can be completely drained from the oil reservoir WARNING Oil may be warm to hot It is recommended to wear gloves for protection 3 Tilt the generator forwards Fig I so that the oil can drain from the oil ...

Страница 13: ... green position as indicated by an I down Fig O This generator will not start without this switch in the ON position 5 To start the engine slowly pull the recoil starter 15 until you feel it engage and then pull it briskly Fig P When starting the engine for the very first time it may require a number of attempts to start until the fuel has travelled from the tank to the engine Slowly pull the reco...

Страница 14: ... All appliances are rated differently This generator will work only with Australian approved rated appliances with an input voltage of 220 240Va c FigT Check your appliances meet this requirement on its rating label before using them In simple terms if you cant use the product in your home you definitely cannot use it on this generator Overload condition Where the appliances want more power then t...

Страница 15: ...ency protect people that could be in harms way first Carbon build up Carbon build up can be a problem on generators as the loading on the engine can vary considerably Running the generator at low loading for extended periods can cause carbon build up Carbon build up in the engine can be reduced by operating the generator at approximately 75 of rated load for 25 of the time the generator is used i ...

Страница 16: ...d spark plug spanner by rotating in a clockwise direction FigY 2 Remove carbon deposits using a wire brush 3 Check for discoloration on the top of the spark plug 20 The standard colour should be a tan colour 4 Check the spark plug gap The acceptable gap should be between 0 6 0 8mm Fig Z CAUTION Check that no foreign material debris or dust enters the crankcase Replacement spark plugs are available...

Страница 17: ...ch 2 and the 240Va c Outlet power on off switch 1 need to be in the OFF position Air Filter It is very important to maintain an air filter 18 in proper condition Damage to the generator may arise if the filter has Improperly been serviced Dirt and other foreign elements adhering to the filter due to improper installation and engine wear It is recommended the air filter 18 is cleaned every 50 hours...

Страница 18: ... wire arms compressed slide the hose clamp up onto the connection of the hose and the tap 7 Refill the tank with fuel and ensure there are no leaks between the fuel tap lever 23 and the tank and with the fuel tap turned on ensure there are no leaks where the fuel hose is fitted to the outlet of the tap AG AF AH 1 Keep your machine clean The outside of the machine can be cleaned using a damp soft c...

Страница 19: ...ents for repair or call us 1800 909 909 for advice A listing of our Service Agents is included with your product however you can also find our most updated listing on our website https help tools by clicking on the Service Agent link Environmental Protection Troubleshooting Service Support Environmental Protection What your 3 year warranty means Troubleshooting Trouble Possible cause Suggested rem...

Страница 20: ...aulty power cord 3 Have an electrician replace cord 4 240Va c Outlet Power On Off switch 1 turned off 4 Check the 240Va c Outlet Power On Off switch 1 is ON Repeated overload 1 Overload 1 Reduce load 2 Faulty cords or equipment 2 Check for damaged bare or frayed wires on equipment Replace Generator overheating 1 Generator overloaded 1 Reduce load 2 Insufficient ventilation 2 Move to adequate suppl...

Страница 21: ...products are developed to our stringent quality specifications If you are not entirely satisfied with this product please return it to your nearest ALDI store within 60 days from the date of purchase for a full refund or replacement or take advantage of our after sales support by calling the supplier s Customer Service Hotline Made in China WORKZONE TITANIUM is a registered trademark of ALDI Store...