5. Disconnect the connected pneumatic tools before you clean the compressor.
6. Rub off the compressor with a clean cloth or blow the compressor off with
compressed air at low pressure to remove dust and dirt.
7. Let all parts dry completely.
Replacing the mains connection line
WARNING!
Risk of electric shock!
If the mains connection line is damaged or is improperly
mounted, there is a risk of electric shock.
- The mains connection line may only be replaced by the
manufacturer, its customer service or a similarly qualified
specialist to avoid risks.
- If the mains connection line of this compressor is damaged,
have it replaced by a qualified specialist before using the
compressor again.
Storage
NOTE!
Risk of damage!
The compressor can be damaged as the result of incorrect or
improper storage.
- Pull the mains plug each time before you store the device.
- Only store the compressor and all connected pneumatic tools
in a vented state.
- Always store the compressor in a safe, dry environment.
- Always store the compressor in a room that is not accessible
for children.
- Always store the compressor so that it cannot be operated by
unauthorised persons.
1. Pull the mains plug of the compressor.
2. Let the compressor cool off completely.
Cleaning