Installing the 1756-Show I/O
3
M
odule
S
e
tup
Installing the 1756-Show I/O
The Alcorn McBride 1756-Show I/O plugs directly into a standard ControlLogix
chassis. The module is compatible with all ControlLogix modular processors,
including the Logix5550 and Logix5555.
Setting the SMPTE Output Level
If the module is being used to generate SMPTE time code, set the SMPTE time
code output level before installing the module in the chassis. The 1756-Show
I/O includes one eight-position switch at the edge of the circuit board, labeled
SW1, to select the output level, measured in volts peak to peak.
Switch SW1 Settings
1 2 3 4 5 6 7 8
4.0 Vpp
On
Off Off Off Off Off Off Off
3.5 Vpp
Off
On
Off Off Off Off Off Off
3.0 Vpp
Off
Off
On
Off Off Off Off Off
2.5
Vpp Off Off Off On
Off Off Off Off
O
u
tput
Level
2.0
Vpp Off Off Off Off On
Off Off Off
Module Power Consumption
The 1756-Show I/O module draws a maximum of 0.420 Amps at 5 VDC. The
module uses 0.001 Amps at 24VDC.