All communications with the 1756-Show I/O takes place through the Output and
Input Data Files. The module can be configured manually or, for ease of setup,
you can use the .ACD file that is included on disk (or from www.alcorn.com) as
a quick reference.
Module Configuration
The 1756-Show I/O module is configured as a Generic 1756 Module. If you
are using the existing .ACD file, you can base your program from this file and
use this configuration. If you would like to configure the module manually, it is
necessary to Add a New Module All Configuration is done using
RSLogix5000.
1. Right-Click on the I/O Configuration and choose New Module…
2. Select the “1756-MODULE Generic 1756 Module” module type.
3. In the first configuration screen, enter the information as seen below: