background image

 

Troubleshooting 

 

WARNING DISPLAY

 “

bAt

”: If you see “bAt” in the display, the battery power is low. Please replace 

the batteries with a new pair.  Make sure to properly align the batteries by looking at the +/- marks.

 

 

WARNING DISPLAY

 "

Er

":

 If this code appear in the display, the device is reporting a general 

problem with the alcohol sensor, or that the device has been physically damaged.  Please 
purchase a new device. 

 

For the other troubles, please contact AK GlobalTech at 

[email protected]

, along with your 

error codes and photos if available.   
 

 

- Specifications - 

Method of Measure  Breath sample to BAC 

Detection Range  0.00% - 0.40% (Accuracy:  +/- 0.01% up to 0.10% BAC) 

Sensor  Oxide semiconductor 

Power  Two 1.5V AA alkaline batteries (included) 

Warm-up Time  Less than 1 minute 

Testing Capacity  Approx. 200 with new batteries 

DOT Approved  YES 

Operating Temperature  50 - 104 degrees Fahrenheit or  

10 - 40 degrees Celsius 

Warm Up  Less than 1 minute 

Display  3-Digit LCD (0.00) 

Dimensions  4.1 H x 1.6 W x 0.8 D 

Weight  3 oz 

Sensor Module  Sensor modules should be replaced every 200 tests or at least once yearly 

(whichever comes first).  

Warranty  One (1) Year (Refer to "Warranty" section) 

 

 

- Limited Warranty - 

Manufacturer's Warranty Coverage 

AK GlobalTech Corporation warrants the AlcoScan AL2500 to be free from defects in workmanship or 
material, excluding spent or used sensor modules, under normal use for one (1) year from the date of 
purchase.  AK GlobalTech's obligation under this warranty is limited to replacing, adjusting or repairing 
the unit only if returned along with proof of purchase, complete shipping address, daytime contact 

Содержание Alcoscan AL2500

Страница 1: ...1 DIGITAL PERSONAL BREATHALYZER AlcoScan AL2500 AlcoScan AL2500 Operator s Manual...

Страница 2: ...2...

Страница 3: ...quired The AlcoScan AL2500 is intended to measure alcohol in human breath Readings obtained by this device are used in the diagnosis of alcohol intoxication The accuracy of this device has been establ...

Страница 4: ...f a sample is not taken within 20 seconds you will hear four 4 beeps and the unit will shut itself off You can also press the POWER button again to manually shut off the unit 3 Analysis and Display On...

Страница 5: ...air samples not mouth air to calculate alcohol content Any contaminants in the mouth including alcohol food smoke or even excess saliva may interfere with testing This includes alcohol based mouthwash...

Страница 6: ...ne batteries included Warm up Time Less than 1 minute Testing Capacity Approx 200 with new batteries DOT Approved YES Operating Temperature 50 104 degrees Fahrenheit or 10 40 degrees Celsius Warm Up L...

Страница 7: ...cohol concentration depends on many variables including environmental factors such as air quality wind humidity temperature etc and health conditions of the test subject A low g dL or BAC reading does...

Страница 8: ...RY INCLUDING BUT NOT LIMTED TO LOSS OF USE LOSS OF REVENUE OR INCOME LOSS OF ACTUAL OR ANTICIPATED PROFITS INFLUDING LOSS OF PROFITS FROM A CONTRACT LOSS OF THE USE OF MONEY LOSS OF ANTICIPATED SAVING...

Отзывы: