CHANGING NOSEPIECES 
 

1.

 

After selecting the correct size nosepiece for the rivet being used Connect tool to 

air supply and pull trigger and hold trigger button.

  

2.

 

 Using wrench (supplied), unscrew nosepiece from frame head & replace with 

proper size nosepiece. Tighten down with wrench. DO NOT OVERTIGHTEN. 
Release trigger. 

 

Your tool is now ready to work. Insert rivet mandrel into nosepiece. Insert rivet into 

predrilled hole in application and pull trigger button and hold until rivet sets then release 
the trigger. A second pull may be required. 

 

 

CLEANING & CHANGING OF JAWS 

 

With use, the jaws of the tool may become dirty or worn. This will cause slipping of the 
rivet mandrel & and improper setting of the rivet. To clean the jaws follow this 

procedure. 

 

1. Disconnect air supply. 
2. Use a suitable wrench, unscrew frame head and remove. 
3. Using a pair of wrenches, disassemble front jaw case from rear jaw case. 

    DO NOT MOVE rear jaw case as this will affect tool operation. 
4. To clean jaws, use a stiff dry wire brush. 

5. If excessive wear is apparent, replace with new jaws. 
6. Reassemble the jaw case assembly. 

 
 

 
 
 

 

WARNING:   ALWAYS WEAR SAFETY GLASSES

  

WHEN OPERATING AND PERFORMING MAINTENANCE ON TOOL 