background image

system you can turn the vacuum system clockwise to shut it off. The tool will 
still be able to set rivets, but it must be tilted backwards to allow spent mandrel 
to fall into nail container.

 

  

 

 
 

 

 

 
 

ADDITION OF HYDRAULIC FLUID 

 

Tool is shipped with oil. If it becomes necessary to add oil, follow this procedure.  

 Please use the supplied priming pump as shown (fig. 4) 

  
 
 
 
 
 

 
              1

Disconnect air supply to tool and 

switch ON/OFF valve to OFF position. 
                                                                               
 
 
 
 
 
 
 
 
2

Remove seal screw and seal (see Fig. 3)  

  

3. Screw the priming pump of filled oil into the 
bleed screw hole. Actuate the priming pump by 
pressing down and releasing several times until 
resistance is felt. (Fig. 4) 
  
4. Remove the priming pump and the excessive oil 
will flow out. Wipe away and clean out the 
excessive oil and replace the seal and screw. 
 
 IMPORTANT: Use only Anti-Foam Hydraulic Fluid    

WARNING:   ALWAYS WEAR SAFETY GLASSES

  

WHEN OPERATING AND PERFORMING MAINTENANCE ON TOOL 