READER

PANEL

Thread cables through and attach  
wall plate to 2-gang box

Wire cable harness to badge reader  
and access control panel

Step 3 –

Step 2 –

Connection Overview

Minimum Required Connections

Caution: Incorrect wiring may cause permanent damage

Wire the badge reader and Access Control system as required for your installation

For installations that require 1-Wire LED control, connect the ORANGE wire (Panel 
LED Green) to the LED terminal on the panel

Attach wall plate to 2-gang box with provided screws, paying attention to 
point the arrow towards door 

Installed screw heads must be flush to the wall plate. Protruding screw 
heads will cause interference when installing the Rock onto the wall plate

Use edge of tunnel to level wall plate

Arrow towards door
PoE+ Ethernet
Wiring harness

Alcatraz 
Rock

Shielded 

Cat5e/Cat6

Badge 
Reader

Badge 

Reader

Ac

cess 

Control 

P

anel

Access 
Control 
Panel

PoE+ Ethernet

Wiegand/OSDP Cable

RED
BLACK
GREEN
WHITE

+12v
GND

D0

D1

+12v
GND

D0

D1

LED Green

RED
BLACK
GREEN
WHITE
ORANGE

PoE+ input power: 42-57 VDC 0.5

A

Refer to enclosed Installation Guide part number

 

541-0001-00-00 Rev 01 for Wiring Diagram

.