Network Interface (NI) Modules
GNI Modules
OmniSwitch 7700/7800 Hardware Users Guide
April 2005
page 5-17
Installing MiniGBIC Connectors
If you are installing an OS7-GNI-U12 module, you must install Miniature Gigabit Interface Converters
(MiniGBICs) as required. OS7-GNI-U12 modules provide ports for up to twelve MiniGBICs. These Mini-
GBIC are packaged separately.
Note.
Be sure you have eliminated ESD by using the provided grounding wrist strap. Refer to
Grounding Wrist Strap and Chassis Grounding Lug” on page 5-24
for more information.
To install a MiniGBIC follow the steps below.
1
When inserting a MiniGBIC, be sure that the hinged face is closed.
2
Slide the MiniGBIC straight into the slot until the module clicks firmly into place.
3
Push the MiniGBIC into the slot until it clicks into place.
Note.
The diagram below is a representation only; the physical appearance of the actual MiniGBIC may
vary.
Caution.
The MiniGBIC should slide in easily. Do not force it into the slot. If any resistance is encoun-
tered, ensure the MiniGBIC is aligned properly. Forcing the MiniGBIC into the slot can damage the unit,
as well as components on your GNI module.
Note.
To remove a MiniGBIC, you must first open the MiniGBIC’s hinged face to approximately ninety
degrees. Then, grasp the hinged face and carefully pull the MiniGBIC straight out of the slot.
LIN
K
A C
T
LINK
A C
T
LINK
A C
T
LINK
A C
T
8
7
6
MiniGBIC Module
MiniGBIC Slot
GNI Module