7705 SAR T1/E1 ASAP Adapter Card Installation Guide
Page 9
Preface
About This Guide
This guide provides site preparation recommendations and step-by-step procedures to
install, remove, and replace the Alcatel-Lucent 16-port and 32-port T1/E1 Any Service Any
Port (ASAP) Adapter cards on the 7705 SAR-8 and 7705 SAR-18. After the hardware
installation process is completed, refer to the
List of Technical Publications
for details on the
boot process, software configuration, and Command Line Interface (CLI) information to
configure system and network parameters.
The 16-port T1/E1 ASAP Adapter card and 32-port T1/E1 ASAP Adapter card support
channelization down to DS0. Each port supports TDM, Inverse Multiplexing over ATM
(IMA), and multilink bundles over PPP channels (MLPPP). A single 68-pin AMP connector
on the 16-port T1/E1 ASAP Adapter card faceplate provides access and network
connections for all ports. The 32-port T1/E1 ASAP Adapter card has two 68-pin AMP
connectors that provide this functionality.
T1/E1 ASAP Card Versions
The 7705 SAR-8 and 7705 SAR-18 support the 16-port T1/E1 ASAP Adapter card version 1
(a16-chds1) and version 2 (a16-chds1v2), and the 32-port T1/E1 ASAP Adapter card
version 2 (a32-chds1v2).
The 16-port T1/E1 ASAP Adapter card version 1 has a -48V/-60 VDC and +24 VDC
variant. The 16-port T1/E1 ASAP Adapter card version 2 and 32-port T1/E1 ASAP Adapter
card version 2 have a wide-range input and support -48/-60 VDC and +24 VDC power
(+24 VDC power is not supported on the 7705 SAR-18).
Warning:
All plugs must be properly crimped and conform to FCC Code of Regulations
(CFR) Part 68, Subpart F. Failure to comply will result in damage to the jack.
Note:
Unless otherwise stated, 16-port T1/E1 ASAP Adapter card in this guide means both
versions and 32-port T1/E1 ASAP Adapter card means version 2 of the card.