Figure 4.67: ARI Number
Note 1:
The ARI Number is the only non plug and play device on the IBS.
The default configuration fits with the major systems. Modifications should answer to specific needs.
Line length
The Line length is the cable length used to plug the IBS to the system (distance between the
IBS and OmniPCX Office). It enables the system to add a delay in signal and to avoid a shift in
clock signal that creates a reset of the IBS.
-
1 In OMC, go to Users/Base stations List.
-
2 Select the IBS Master and click Details
There are 3 possibilities of configuration:
-
Short line (0-400 meters)
-
Medium line (400-800 meters)
-
Long line (800-1200 meters)
Restart the IBS after you have modified the Line length parameter.
Antenna diversity
Antenna diversity is the ability of the IBS to move the transmission and reception from one
antenna to the other so that the signal is always of the highest quality.
Restart the IBS after you have modified the Antenna diversity parameter.
Silent-Noisy IBS
Enable the Silent-Noisy IBS parameter to set up the echo canceller device.
Chapter
4
( )
4-94
Содержание OmniPCX Office
Страница 1: ...Installation Manual Release 9 0 October 2012 ...
Страница 8: ... P 8 6 Q 8 7 R 8 7 S 8 8 T 8 8 U 8 9 V 8 9 W 8 9 0 6 ...
Страница 14: ...Chapter 1 1 6 ...
Страница 19: ...2 3 Installation 2 3 1 Overview ___change begin___ 2 5 ...
Страница 48: ...Chapter 3 3 18 ...
Страница 176: ...Chapter 4 4 128 ...
Страница 178: ...Figure 5 1 Virtual Key Functions for Operator Sets in KeySystem mode Chapter 5 5 2 ...
Страница 179: ...Figure 5 2 Virtual Key Functions for Manager Assistant Normal sets in KeySystem Mode 5 3 ...
Страница 180: ...Figure 5 3 Virtual Key Functions for Attendant sets in KeySystem Mode with no Physical Add on Chapter 5 5 4 ...
Страница 181: ...Figure 5 4 Virtual and Physical Add on Key Functions for Attendant Sets in KeySystem mode 5 5 ...
Страница 182: ...Figure 5 5 US only Virtual Key Functions for Operator Sets in KeySystem Mode Chapter 5 5 6 ...
Страница 183: ...Figure 5 6 US only Virtual Key Functions for Manager Assistant Sets in KeySystem Mode 5 7 ...
Страница 184: ...Figure 5 7 US only Virtual Key Functions for Normal Sets in KeySystem Mode Chapter 5 5 8 ...
Страница 185: ...Figure 5 8 Virtual Key Functions for Operator Manager Assistant Normal Sets in PABX Mode 5 9 ...
Страница 186: ...Figure 5 9 US only Virtual Key Functions for Operator Sets in PABX Mode Chapter 5 5 10 ...
Страница 187: ...Figure 5 10 US only Virtual Key Functions for Manager Assistant Sets in PABX Mode 5 11 ...
Страница 190: ...Chapter 5 5 14 ...
Страница 213: ...settings are overwritten when configured PBXs are added to a network 6 23 ...
Страница 214: ...Chapter 6 6 24 ...
Страница 220: ...Chapter 7 7 6 ...