Running application at: 0x00200140
Flash configuration read
Parsing text mode configuration ...
Configuration parsed
Initializing
Press any key to get started
Once the APC PoE card has been installed, we can connect the PoE source to the device:
Fig. 32:
Connecting the PoE source to the device: Schema
3.5 Microswitches
The OA58XX-NW router has a block of eight available micro-switches (located on the underside of the device) used
for maintenance and test purposes.
In this case, they are only used to load the default configuration. These switches should not be handled by the user
other than to load the default configuration.
Note
For the device to operate correctly, all micro-switches must be in the OFF position.
The default configuration for the router establishes the access IP and mask address as follows:
• IP address: 192.168.1.1
• IP mask: 255.255.255.0
Note
Some devices leave the factory with customized settings. This personalization can mean that the de-
fault configuration is different from the one shown above.
3.5.1 Procedure to ignore the configuration
Follow these steps if you have to discard the whole configuration of the device (for instance, if you cannot remember
the password).
• Turn off the device through the ON/OFF switch.
• Open the device.
• Using a screwdriver, move micro-switch ‘5’ to the ON position.
• Close the device.
• Turn the device on with the ON/OFF switch.
3 Components and Power Supply
Alcatel-Lucent
20
OA58XX-NW Router