background image

 

OAW-RAP155 / OAW-

RAP155P Remote Access 

Point

Installation Guide

OAW-RAP155 / OAW-RAP155P Remote Access Point | Installation Guide
Part Number 0511330-01 | May 2013

Contacting Support

Contact Center Online

Main Site

http://www.alcatel-lucent.com/enterprise

Support Site

https://service.esd.alcatel-lucent.com

Email

[email protected]

Service & Support Contact Center Telephone

North America

1-800-995-2696

Latin America

1-877-919-9526

Europe

+33 (0) 38 855 6929

Asia Pacific

+65 6240 8484

Worldwide

1-818-878-4507

 

Copyright

© 2013 Alcatel-Lucent. All rights reserved.

Specifications in this manual are subject to change without notice.

Originated in the USA.

AOS-W, Alcatel 4302, Alcatel 4304, Alcatel 4306, Alcatel 4308, Alcatel 4324, Alcatel 4504, Alcatel 4604, Alcatel 
4704, Alcatel 6000, OAW-AP41, OAW-AP68, OAW-AP60/61/65, OAW-AP70, OAW-AP80, OAW-AP92/93, OAW-
AP105, OAW-AP120/121, OAW-AP124/125, OAW-AP175, OAW-IAP92/93/105, OAW-RAP2, OAW-RAP5, and 
Omnivista 3600 Air Manager are trademarks of Alcatel-Lucent in the United States and certain other countries.

Any other trademarks appearing in this manual are the property of their respective companies. Includes software 
from Litech Systems Design. The IF-MAP client library copyright 2011 Infoblox, Inc. All rights reserved. This 
product includes software developed by Lars Fenneberg et al.

Legal Notice

The use of Alcatel-Lucent switching platforms and software, by all individuals or 
corporations, to terminate Cisco or Nortel VPN client devices constitutes complete 
acceptance of liability by that individual or corporation for this action and indemnifies, in 
full, Alcatel- Lucent from any and all legal actions that might be taken against it with 
respect to infringement of copyright on behalf of Cisco Systems or Nortel Networks.

 

Figure 5  

IAP-RAP Conversion over the Internet

Wall Mounting Instructions

The two mount holes (the center-to-center distance is 26mm) are covered by the 
plastic plate with Alcatel-Lucent logo on the back of the OAW-RAP155 and 
OAW-RAP155P as shown in 

Figure 6

. The mount holes can be used to attach the 

device upright to an indoor wall as shown in 

Figure 7

. To install OAW-RAP155 

and OAW-RAP155P on a wall: 

1. At the mounting location, install two screw on the wall, 26mm apart 

2. Remove the plastic plate, align the mount holes over the screws and slide the 

unit into place.

Figure 6  

Mount Holes on the Back of OAW-RAP155/OAW-RAP155P

Figure 7  

Mounting OAW-RAP155/OAW-RAP155P on a Wall

Product Specifications

Electrical

Ethernet:

5 x 10/100/1000BASE-T auto-sensing Ethernet RJ-45 Interfaces 

MDI/MDX

10/100/1000BASE-T are IEEE 802.3 and EEE 802.3u compliant.

Power - OAW-RAP155:

12 VDC power interface, supports powering through an AC-to-DC power 
adapter

Power - OAW-RAP155P: 

54 VDC power interface, supports powering through an AC-to-DC power 
adapter

PoE feature support (OAW-RAP155P only)

Supply PoE power to up to two IEEE 802.3af powered device (class 0-4) 
on E1 and E2 port (the output power is 13 watts at each port)

Supply PoE power to one IEEE 802.3at powered device on either E1 or E2 
port (the output power is 25.5 watts)

For additional specifications on this product, please refer to the data sheet. The 
data sheet can be found at 

www.alcatel-lucent.com

.

Proper Disposal of Alcatel-Lucent Equipment

For the most current information about Global Environmental Compliance and 
Alcatel-Lucent products, see our website at 

www.alcatel-lucent.com

.

Waste of Electrical and Electronic Equipment

Alcatel-Lucent products at end of life are subject to separate 
collection and treatment in the EU Member States, Norway, and 
Switzerland and therefore are marked with the symbol shown at 
the left (crossed-out wheelie bin). The treatment applied at end 
of life of these products in these countries shall comply with the 
applicable national laws of countries implementing Directive 

2002/96EC on Waste of Electrical and Electronic Equipment (WEEE).

European Union RoHS

Alcatel-Lucent products also comply with the EU 
Restriction of Hazardous Substances Directive 2002/95/EC 
(RoHS). EU RoHS restricts the use of specific hazardous 

materials in the manufacture of electrical and electronic equipment. Specifically, 
restricted materials under the RoHS Directive are Lead (including Solder used in 
printed circuit assemblies), Cadmium, Mercury, Hexavalent Chromium, and 
Bromine. Some Alcatel-Lucent products are subject to the exemptions listed in 
RoHS Directive Annex 7 (Lead in solder used in printed circuit assemblies). 
Products and packaging will be marked with the “RoHS” label shown at the left 
indicating conformance to this Directive.

China RoHS

Alcatel-Lucent products also comply with China environmental 
declaration requirements and are labeled with the “EFUP 10” label 
shown at the left.

Safety and Regulatory Compliance

Alcatel-Lucent Networks provides a multi-language document that contains 
country-specific restrictions and additional safety and regulatory information for 
all Alcatel-Lucent access points. This document can be viewed or downloaded 
from the following location: 

https://service.esd.alcatel-lucent.com

Regulatory Model Names

The following regulatory model names apply to the OAW-RAP155 and 
OAW-RAP155P:

OAW-RAP155: APINR155

OAW-RAP155P: APINR15P

EMC Compliance and Warning Statement

FCC Class B Part 15

This device complies with Part 15 of the Federal Communications Commission 
(FCC) Rules. Operation is subject to the following two conditions:

This device may not cause harmful interference.

This device must accept any interference received, including interference that 
may cause undesired operation.

The device has been found to be compliant to the requirements set forth in CFR 
47 Sections 2.1091 for an uncontrolled environment. The antenna(s) used for this 
transmitter must be installed to provide a separation distance of at least 20 cm 
from all persons and must not be co-located or operating in conjunction with any 
other antenna or transmitter. 

This equipment has been tested and found to comply with the limits for a Class B 
digital device, pursuant to Part 15 of the FCC Rules. This equipment generates, 
uses and can radiate radio frequency energy and, if not installed and used in 
accordance with the manufacturer’s instructions, may cause interference 
harmful to radio communications.

If this equipment does cause interference, which can be determined by turning 
the equipment off and on, the user is encouraged to try to correct the 
interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment to an outlet on a circuit different from that to which 
the receiver is connected.

Consult the dealer or an experienced radio or TV technician for help.

Complies with the Class B limits for radio noise emissions as set out in the 
interference-causing equipment standard entitled “Digital Apparatus,” ICES-003 
of Industry Canada.

Cet apareil numerique de la classe B respecte toutes les exigencies du Reglement 
sur le materiel brouilleur du Canada.

L ‘ utilisation de ce dispositif est autorisée seulement aux conditions suivantes : 
(1) il ne doit pas produire de brouillage et (2) l’ utilisateur du dispositif doit étre 
prêt à accepter tout brouillage radioélectrique reçu, même si ce brouillage est 
susceptible de compromettre le fonctionnement du dispositif. 

Le présent appareil est conforme aux normes CNR d’industrie Canada 
applicables aux appareils radio exempts licence. L’exploitation est autorisée aux 
deux conditions suivantes:

1. L’appareil ne doit produire de brouillage, et

2. L’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, 

même si le brouillage est susceptible d’en compromettre le fonctionnement.

EU Regulatory Conformance 

This product is CE marked according to the provisions of the R & 
TTE Directive (99/5/EC) - CE(!). Alcatel-Lucent Networks, hereby 

declares that the APINR155 / APINR15P device models are in compliance with 
the essential requirements and other relevant provisions of Directive 1999/5/EC -
CE(!)

The Declaration of Conformity made under Directive 1999/5/EC is available for 

viewing at the following location: 

www.alcatel-lucent.com

Two mount holes 
located under this 
plastic plate

!

CAUTION

Alcatel-Lucent access points must be installed by a professional installer. 

The professional installer is responsible for ensuring that grounding is 

available and it meets applicable local and national electrical codes.

!

CAUTION

RF Radiation Exposure Statement:

 This equipment complies with FCC 

RF radiation exposure limits. This equipment should be installed and 

operated with a minimum distance of 35cm between the radiator and 

your body. This transmitter must not be co-located or operating in 

conjunction with any other antenna or transmitter. 

10

᳝↦᳝ᆇ⠽䋼ໄᯢ

Hazardous Materials Declaration

᳝↦᳝ᆇ⠽䋼៪ܗ㋴

(Hazardous Substance) 

䚼ӊৡ⿄

(Parts) 

3E

+J

&G

݁Ӌ䫀

&U

໮⒈㘨㣃

3%%

໮⒈Ѡ㣃䝮

3%'(

⬉䏃ᵓ

(

PCA Boards)

h

ƻ

ƻ

ƻ

ƻ

ƻ

ᴎẄ㒘ӊ

(

Mechanical Sub-Assemblies)

h

ƻ

ƻ

ƻ

ƻ

ƻ


ƻ˖ 㸼⼎䆹᳝↦᳝ᆇ⠽䋼೼䆹䚼ӊ᠔᳝ഛ䋼ᴤ᭭Ёⱘ৿䞣ഛ೼

SJ/T11363-2006

ᷛޚ㾘ᅮⱘ䰤䞣㽕∖ҹϟDŽ

Indicates that the concentration of the hazardous substance in all homogeneous materials in the parts is 
below the relevant threshold of the SJ/T11363-2006 standard.


h˖ 㸼⼎䆹᳝↦᳝ᆇ⠽䋼㟇ᇥ೼䆹䚼ӊⱘᶤϔഛ䋼ᴤ᭭Ёⱘ৿䞣䍙ߎ6-7ᷛޚ㾘ᅮⱘ䰤䞣㽕∖DŽ

Indicates that the concentration of the hazardous substance of at least one of all homogeneous materials 
in the parts is above the relevant threshold of the SJ/T11363-2006 standard. 

ᇍ䫔ଂП᮹ⱘ᠔ଂѻકᴀ㸼ᰒ⼎կᑨ䫒ⱘ⬉ᄤֵᙃѻકৃ㛑ࣙ৿䖭ѯ⠽䋼DŽ

This table shows where these substances may be found in the supply chain of electronic information 

products, as of the date of sale of the enclosed product.   

ℸᷛᖫЎ䩜ᇍ᠔⍝ঞѻકⱘ⦃ֱՓ⫼ᳳᷛᖫᶤѯ䳊䚼ӊӮ᳝ϔϾϡৠⱘ⦃ֱՓ⫼ᳳ
՟བ⬉∴ऩܗ῵ഫ䌈೼݊ѻકϞ
ℸ⦃ֱՓ⫼ᳳ䰤া䗖⫼Ѣѻકᰃ೼ѻક᠟ݠЁ᠔㾘ᅮⱘᴵӊϟᎹ԰

The Environment- Friendly Use Period (EFUP) for all enclosed products and their parts are 
per the symbol shown here. The Environment- Friendly Use Period is valid only when the 
product is operated under the conditions defined in the product manual. 

!

CAUTION

Changes or modifications to this unit not expressly approved by the 

party responsible for compliance could void the user’s authority to 

operate this equipment.

Отзывы: