Warning
All interconnected communication devices should be plugged to THE SAME GROUNDED POWER
OUTLET, which should, at the same time, be of good quality (lower than 10 ohms).
Whether the workplace is provided with an uninterrupted power supply system (UPS), regulated supply
or it is independent from the rest (such as lighting, etc.); it is highly recommended that all data devices
should be connected to the same power source. This will avoid operating and premature aging prob-
lems of drivers and other components.
3.4.2 Connecting
• Make sure the router’s power supply switch is in the OFF position (0).
• Ensure that the power supply is NOT connected to either the electricity or the router.
• Connect all data cables.
• Connect the power supply cable to the device.
• Connect the power supply cable to the electricity supply.
• Set the router’s power supply switch to the ON position (1).
3.4.3 Disconnect
• Make sure the router’s power supply switch is in the OFF position (0).
• Disconnect the power supply from the electricity supply.
• Disconnect the power supply from the router.
• Disconnect the data cables.
3.5 RST Button
The different RST button features are described below.
3.5.1 Rebooting the device
Once the device is operating normally, press the RST button for it to restart.
3.5.2 Default Configuration
The RST button allows you to boot the device with its default configuration through the following steps:
• With the device switched off, keep the RST button pressed and switch on the router using the ON/OFF switch (1).
• The Power LED (green) will light up and the USB LED will begin to blink (green). Blinking will continue for 10
seconds.
• For the device to boot with the default configuration, release the RST button while the USB LED is blinking (i.e. be-
fore the 10 second period expires).
The router’s default configuration establishes the following IP address and mask:
• IP address: 192.168.1.1
• IP mask: 255.255.255.0
Note
Some devices leave the factory with customized settings. This personalization can mean that the de-
fault configuration may be different from the one shown above.