SNMP Configuration Overview
Page 256
7950 SR OS System Management Guide
SNMP Configuration Overview
This section describes how to configure SNMP components which apply to SNMPv1 and
SNMPv2c, and SNMPv3 on the router.
•
Configuring SNMPv1 and SNMPv2c on page 256
•
Configuring SNMPv3 on page 256
Configuring SNMPv1 and SNMPv2c
Alcatel-Lucent routers are based on SNMPv3. To use the routers with SNMPv1 and/or SNMPv2c,
SNMP community strings must be configured. Three pre-defined access methods are available
when SNMPv1 or SNMPv2c access is required. Each access method (
r
,
rw
, or
rwa
) is associated
with an SNMPv3 access group that determines the access privileges and the scope of managed
objects available. The
community
command is used to associate a community string with a
specific access method and the required SNMP version (SNMPv1 or SNMPv2c). The access
methods are:
•
Read-Only — Grants read only access to the entire management structure with the
exception of the security area.
•
Read-Write — Grants read and write access to the entire management structure with the
exception of the security area.
•
Read-Write-All — Grants read and write access to the entire management structure,
including security.
If the predefined access groups do not meet your access requirements, then additional access
groups and views can be configured. The
usm-community
command is used to associate an
access group with an SNMPv1 or SNMPv2c community string.
SNMP trap destinations are configured in the
config>log>snmp-trap-group
context.
Configuring SNMPv3
The OSimplements SNMPv3. If security features other than the default views are required, then
the following parameters must be configured:
•
Configure views
•
Configure access groups
•
Configure SNMP users
Содержание 7950 SR
Страница 10: ...Page 10 7950 SR OS System Management Guide List of Figures...
Страница 14: ...About This Guide Page 14 7950 SR OS System Management Guide...
Страница 16: ...Alcatel Lucent 7950 SR Router Configuration Process Page 16 7950 SR OS System Management Guide...
Страница 56: ...Configuration Notes Page 56 7950 SR OS System Management Guide...
Страница 88: ...Configuring Login Controls Page 88 7950 SR OS System Management Guide...
Страница 106: ...Security Command Reference Page 106 7950 SR OS System Management Guide...
Страница 206: ...Distributed CPU Protection Commands Page 206 7950 SR OS System Management Guide...
Страница 244: ...Debug Commands Page 244 7950 SR OS System Management Guide...
Страница 254: ...Configuration Notes Page 254 7950 SR OS System Management Guide...
Страница 276: ...SNMP Security Commands Page 276 7950 SR OS System Management Guide...
Страница 296: ...Show Commands Page 296 7950 SR OS System Management Guide...
Страница 322: ...Configuration Notes Page 322 7950 SR OS System Management Guide...
Страница 358: ...Log Management Tasks Page 358 7950 SR OS System Management Guide...
Страница 454: ...Facility Alarm List Page 454 7950 SR OS System Management Guide...
Страница 460: ...Standards and Protocols Page 460 Standards and Protocols...