SNMP
7705 SAR OS System Management Guide
189
Default
attempts 20 time 5 lockout 10
Parameters
count —
the number of unsuccessful SNMP attempts allowed for the specified time
Values
1 to 64
Default
20
time
minutes1
—
the period of time, in minutes, that a specified number of unsuccessful attempts
can be made before the host is locked out
Values
0 to 60
Default
5
lockout
minutes2
—
the lockout period, in minutes, during which the host is not allowed to log in.
When the host exceeds the attempted count times in the specified time, then that host is locked
out from any further login attempts for the configured time period.
Values
0 to 1440
Default
10
community
Syntax
community
community-string
[
hash
|
hash2
]
access-permissions
[
version
SNMP-version
]
no community
community-string
[
hash
|
hash2
]
Context
config>system>security>snmp
Description
This command creates SNMP community strings for SNMPv1 and SNMPv2c access. This command
is used in combination with the predefined access groups and views. To create custom access groups
and views and associate them with SNMPv1 or SNMPv2c access, use the
usm-community
command.
When configured, community implies a security model for SNMPv1 and SNMPv2c only.
For SNMPv3 security, the
command must be configured.
The
no
form of the command removes a community string.
Default
n/a
Parameters
community-string —
configures the SNMPv1/SNMPv2c community string
hash1 | hash2 —
configures the hashing scheme for the community string
access-permissions —
defines the access permissions
Values
•
r — grants only read access to objects in the MIB, except
security objects
•
rw — grants read and write access to all objects in the
MIB, except security objects
•
rwa — grants read and write access to all objects in the
MIB, including security objects
Содержание 7705 SAR
Страница 10: ...List of Figures 10 7705 SAR OS System Management Guide...
Страница 14: ...About This Guide 14 7705 SAR OS System Management Guide...
Страница 16: ...Alcatel Lucent 7705 SAR System Management Configuration Process 16 7705 SAR OS System Management Guide...
Страница 64: ...Security Configuration Procedures 64 7705 SAR OS System Management Guide...
Страница 168: ...Configuration Notes 168 7705 SAR OS System Management Guide...
Страница 182: ...SNMP Command Reference 182 7705 SAR OS System Management Guide Command Descriptions Configuration Commands Show Commands...
Страница 183: ...SNMP 7705 SAR OS System Management Guide 183 Configuration Commands SNMP System Commands SNMP Security Commands...
Страница 255: ...Event and Accounting Logs 7705 SAR OS System Management Guide 255 Clear Commands clear log log id...
Страница 354: ...Standards and Protocol Support 354 7705 SAR OS System Management Guide...
Страница 356: ...2015 Alcatel Lucent All rights reserved 3HE 09688 AAAA TQZZA Edition 01...