2.2 Feature changes
Load Feature
H0-00
First hardened product load of the 3600/3600+ MainStreet Release 9.0 software
DCR 422188: added new alarm when T1 slips occur
H0-10
DCR 9A1319: added support for new Dual E3-2 card (part number 90-9751-03)
for the 3600 MainStreet multishelf system
PTS fixes
H0-15
DCR 490229: display bank checksum on MAINT – ON_SLOT – CTRL –
SW_GEN screen
DCR 490232: replace Alcatel with Datatel on login screen
H0-21 PTS
fixes
H0
–
25 PTS
fixes
H0
–
26 PTS
fixes
H0
–
30 PTS
fixes
3 Fixed
problems
These problems are fixed in load H0-30 and are organized by priority and PTS number.
3.1 Fixed problems for 3600 and 3600+ MainStreet systems
Critical problems
None
Major problems
PTS number
Title
Description
541080
SNMP trap message errors
Because of the length of the NMTI identifier for the DE3
card, the port ID is truncated in the 5620 Network
Manager alarm queue.
Minor problems
PTS number
Title
Description
563400
Reboot after an unknown
power failure
The 3600+ MainStreet node reboots after experiencing a
bus error due to an invalid statistics request for the 5620
Statistics Collector.
The problem can also affect a 3600 MainStreet multishelf
node.