12
Disconnect the optical power meter and reconnect the fiber to the receive port of LP1.1.
...................................................................................................................................................................................................
13
Remove the optical loop from the ODF and install a variable optical attenuator.
...................................................................................................................................................................................................
14
Increase the attenuation until the PDH analyzer reports single bit errors.
...................................................................................................................................................................................................
15
Decrease the attenuation a little until no errors are reported.
...................................................................................................................................................................................................
16
Wait for approximately 5 minutes (no errors may occur).
...................................................................................................................................................................................................
17
Disconnect the fiber from the Line Port “input” at the physical E port and measure the
optical output level (refer to
Figure 7-2, “Line port connection to optical distribution
...................................................................................................................................................................................................
18
Verify that the requirements mentioned in the table below are met.
Result:
Receiver sensitivity ranges:
Interface
Wavelength [nm]
Receiver sensitivity [dBm]
S1.1
1310
≤ –28
S4.1
1310
≤ –28
L1.1
1310
≤ –34
L1.2
1550
≤ –34
L4.1
1310
≤ –28
L4.2
1550
≤ –28
...................................................................................................................................................................................................
19
Repeat test for Line Port 1.2, LP 1.3, LP1.4 , if applicable.
Cleaning up
The following tasks must be performed to clean up the system:
•
Disconnect the PDH analyzer
•
Disconnect the optical attenuator
Stand-alone test procedures
Line port connection to optical distribution frame test
...................................................................................................................................................................................................................................
...................................................................................................................................................................................................................................
7-10
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
365-313-103R8.0
Issue 2
July 2009
E
N D
O F
S T E P S
...................................................................................................................................................................................................
Содержание 1645 AMC
Страница 14: ......
Страница 20: ......
Страница 36: ......
Страница 50: ......
Страница 68: ......
Страница 106: ......
Страница 114: ......
Страница 164: ......
Страница 166: ......
Страница 174: ......
Страница 178: ......
Страница 182: ......
Страница 208: ......
Страница 216: ......
Страница 220: ......