13
Level sensors
disabled
Dispensing mode
AUTOMATIC
Dispensing mode
MANUAL
Level sensors
enabled
Set up Hopper 1 :
1,00 €
P
ERIPHERAL UNITS
SETUP
EMPTY OUT
HOPPERS
Set up
Cashless
Set up
Dispense mode
Set up
COINS
Set up
TOKENS
Set up
TOKEN + CHANGE
Set up
Note validator
< 5 > 10 20 50 100
NO OK OK OK OK
< 5 > 10 20 50 100
OK OK OK OK OK
7.3.5
S
ETTING UP THE PERIPHERAL UNITS
This menu allows to set up the denominations accepted by the note validator and by the coin
acceptor, as well as the value of the coins/tokens dispensed. It also permits to set the change mode
as either automatic or manual, and to enable/disable the full/void sensors of the hoppers.
(*)
(*)
Press Down or Up
to modify amounts in
discreet steps of 0,01
€ each
7.3.5.1
N
OTE
V
ALIDATOR SETUP
The board automatically detects the presence of the note acceptor during initial check. All the
programmed note values (5-to-100 Euro) get automatically enabled. To modify this default
condition, press OK to get to the first option (ex. 5 €) and highlight it, then press UP or DOWN to
reverse its state
. Press OK to shift to the next option (ex. 10 €).
5 10 < 20 > 50 100
OK OK OK OK OK
5 < 10 > 20 50 100
OK OK OK OK OK
OK
NO
1,00 < 0,50 >
2,00
OK
Set up Hopper 2 :
0,50 €
2,00 < 1,00>
0,50
NO
OK
OK
< 2,00 > 1,00
0,50
NO
OK
OK
Set up
Coin acceptor
Set up
GSM / GPRS
2,00
< 1,00 > 0,50
OK
OK
OK
< 5 > 10 20 50 100
NO OK OK OK OK
5 < 10 > 20 50 100
NO OK OK OK OK
< 5 > 10 20 50 100
OK OK OK OK OK
Set up
Note validator
Exit
5 10 < 20 > 50 100
OK OK OK OK OK
5 < 10 > 20 50 100
OK OK OK OK OK
0,50
OK
OK
OK
< 2,00 > 1,00
(**) When the " CHANGE " option or the
"TOKENS" option is activated in combination with the
"AUTOMATIC DISPENSING" mode, the “Setup Payout
Table” menu is made available. To set the Payout Table,
pls. see sect. 7.3.5.A .