26
Digital Inputs, Binary
Supply Correction (only on voltage input, not available on resistance mode):
IMPORTANT:
The supply voltage correction is used when the voltage inputs are used to measure from the
gauges (it does not matter the brand), since the voltage that is measured is referenced to the
supply voltage. Therefore, if this supply voltage (comes from the alternator or the battery) is not
stable, it produces fluctuations in the measurement. This option attempts to compensate the
measurement based on the deviation of the supply voltage from the expected nominal value.
To do this, the supply voltage must be connected to one of the voltage measurements channels
(usually the last one, Input 12 Voltage) and the expected nominal value must be set on the
configuration website.
Calibration Curve Example
If your sensor/gauge is not included in the predefined list you will have to create.
We have two options:
-
Using calibration table from the manufacturer of the sensor (Recommended)
For example, this VDO sender:
Содержание AlbaCombi