background image

Instructions for installation and operation  -  English 

 

Installation & Use Pares - Marami - Code 10013216 - Edition 2 - 10/2011 – Page 

 

Commissioning of SpaPack (Marami with SpaPack only) 

2.1

Safety Warning for sand filter 

WARNING

: Never start up the system without water. 

 

WARNING:

 Whenever you operate the filter or the selector valve, switch off the pump first. 

 

WARNING:

 Never allow children or adults to sit on the system. 

 

WARNING:

 Do not connect the filter directly to the water network, as the pressure of the water may be too high and exceed 

the maximum work pressure allowed by the filter. 
 

WARNING:

 Do not clean the lid with solvents, as it may damage its properties (finish, transparency…). 

 

WARNING:

 As all the connections are made with joints, it is not necessary to tighten the nuts excessively in order to avoid 

that some plastics pieces could break. 

2.2

Safety Warning for prefilter pump ter 

WARNING:

 This pump is specially designed for the prefiltering and recirculation water in spa. 

 

WARNING:

 It is designed to work with clean water at a temperature of not over 40°C. 

 

WARNING:

 The installation must be carried out by qualified personnel and according to the local safety regulations for spa, 

especially with regard to electric regulations and to the specific instructions for each facility. 
 

WARNING:

 The rules in force on accident prevention should be carefully followed. 

 

WARNING:

  Any  modification  of  the  pump  requires  the  prior  consent  of  the  manufacturer.  Original  replacement 

manufacturer of the pump assumes no liability for the damage and injuries caused by unauthorized replacement parts and 
accessories. 
 

WARNING:

  During  operation,  some  parts  of  the  machine  are  subject  to  dangerous  electric  voltages.  Work  may  only 

performed  on  each  machine  or  on  the  equipment  connected  to  it  after  disconnecting  them  from  the  main  and  after 
disconnecting the starting devices. 
 

WARNING:

 The user should make sure that assembly and maintenance tasks are carried out by qualified authorized persons 

and that these persons have first carefully read the installation and service instructions. 
 

WARNING:

 The operating safety of the machine is only guaranteed if the installation and service instructions are correctly 

followed. 
 

2.3

Warning for installation and assembly tasks 

 

Electrical connections 

See also the document: 

Electrical system, safety distances and danger zones for SPA pools with hydromassage. 

The  motor  must  be  wired  according  the  local  standards:  -  if  in  doubt  consult  a  qualified  electrician.  Check  supply  voltage 
complies with voltage on motor plate. 
When  connecting  electric  cables  to  the  motor  of  the  machine,  be  careful  to  correctly  arrange  them  inside  the  connection 
box, verify that no bits of cable are left inside on closing it, and see that the earth wire is correctly connected. 
Be especially careful that no water whatsoever enters the motor or the electrical parts under voltage. 
In the event that the planned use is not as specified, adaptations and supplementary technical rules may be necessary.

 

Содержание Marami

Страница 1: ...Manual de uso Gebruikershandleiding Priro nik za uporabo Priru nik za upotrebu Manuale installazione Installation manual Installationshandbuch Notice d installation Manual para la instalaci n Manual d...

Страница 2: ...al treatment of the water 16 4 Use of the spa 16 4 1 Presentation of PARES 16 4 2 Presentation of MARAMI 17 4 3 PARES 18 4 4 MARAMI 18 4 5 Operation of the sand filter Marami with SpaPack only 19 4 6...

Страница 3: ...ded installation conditions in the installation manual and make sure they are properly complied with Our factory always endeavours to improve the performances of its spas For this reason it is possibl...

Страница 4: ...health In the event of use with young children or elderly people it is advisable to reduce the water temperature WARNING For use by a pregnant woman we recommend having a maximum temperature of 38 C I...

Страница 5: ...every two months or more often if necessary In order to obtain the detailed instructions for the cleaning and refitting of the cartridge For complete description refer to chapter 5 1 WARNING Change th...

Страница 6: ...STALLATION Make sure that only the base of the spa is embedded and that the side panels remain clear For this type of installation we recommend providing a clearance of approximately 40cm and installi...

Страница 7: ...e checked easily The power supply installation must comply with the provisions of the national legislation The spa must be permanently connected without any intermediate connections to the electric po...

Страница 8: ...requires the prior consent of the manufacturer Original replacement manufacturer of the pump assumes no liability for the damage and injuries caused by unauthorized replacement parts and accessories W...

Страница 9: ...there is no voltage in the circuits including the auxiliary circuits and the supplementary services 4 Wait until the rotor stops completely The above list should be considered indicative and not bind...

Страница 10: ...Installation Use Pares Marami Code 10013216 Edition 2 10 2011 Page 9 HYDRAULIC CONNECTIONS CIRCUIT PUMP 1 one speed pump CIRCUIT PUMP 2 two speed pump out 3 in 3 Pump 1 speed out 2 in 2 Pump 2 speeds...

Страница 11: ...Instructions for installation and operation English Installation Use Pares Marami Code 10013216 Edition 2 10 2011 Page 10 ELECTRIC CONNECTIONS Circulation Pumb Pump two speeds Pump one speed...

Страница 12: ...e Voltage 400 Vac Number of wires 5 Frequency 50 Hz Current consumed see attached table See also the document Electrical system safety distances and danger zones for SPA pools with hydromassage Electr...

Страница 13: ...Choose the entry point of the cable on the most suitable side and drill a cable passage of a corresponding diameter either in the base or in the surrounding panel Put in the power supply cable of 230...

Страница 14: ...er back on the electrical box 3 2 Filling the spa Only fill the spa at its final location Open all slide valves by lifting the handles and locked it by sliding the locking clips on the axes of the sli...

Страница 15: ...tly via the skimmer in order to facilitate the priming of the pumps until the water level covers all the jet spouts but without reaching the level of the lowest headrest Avoid over filling the spa as...

Страница 16: ...Tighten up the coupling and start the pump The pump should prime and air escapes for a moment through the massage nozzles Should the pump not prime quickly stop it and restart the operation Depending...

Страница 17: ...access to the spa in the absence of periods of supervision and to protect it from the wind and pollution we advise you to attach the cover with the lockable cleats supplied with it 3 5 Initial treatme...

Страница 18: ...ts position a diverter valve directs the flow from the pump to a particular sector Maintaining the diverter valve in an intermediate position between two sectors can create some turbulence in the circ...

Страница 19: ...off Waterfall Diverter valve 2 on off Therapy dream collar massage 4 4 MARAMI Diverter valve 1 on off Waterfall Diverter valve 2 on off Therapy dream collar massage Diverter valve 3 on off Foutain jet...

Страница 20: ...ncy from your filter it should be filled with silica sand with a grain size classification between 0 5mm and 0 7mm With the quantity indicated on the plate specifying the characteristics proceed as fo...

Страница 21: ...cause damage to the filter collector unit RECIRCULATE In this position the selector valve allows the water from the pump to go directly to the spa without passing through the inside of filter FILTER F...

Страница 22: ...igh cloudy water Decrease the pH The pressure rises rapidly during a filter cycle Lack of chlorine greenish coloured water Add chlorine The pump is taking in air Check for leaks in the prefilter and s...

Страница 23: ...e condition of the joint Motor turning in the wrong direction only for 3 phases pumps Invert the two phases of the feeding line The pump does not prime Hydraulic network not well dimensioning Too much...

Страница 24: ...In order to display the temperature press once on the buttons or To change the temperature all you have to do is to press again on the keys or After 5 seconds the display will return to normal provide...

Страница 25: ...enced by the presence of a level detector Chromotherapy Press the Light key to switch on the chromotherapy illumination of the spa Press a second time to switch it off It will automatically go off aft...

Страница 26: ...which corresponds to a 10h duration of the function It is possible to set the function between 0h and 24h in intervals of one hour To do that all you have to is press the or key during the display of...

Страница 27: ...conds until the time displayed starts flashing Use the keys and to set the value of the hour then press again on Clock to change the minutes Likewise use the keys and to set the minutes Lastly validat...

Страница 28: ...efore of the need to clean them BEFORE CLEANING THE FILTRATION CARTRIDGES ALWAYS SWITCH OFF THE SPA POWER SUPPLY 5 2 Draining and filling the spa WARNING READ THE FOLLOWING INSTRUCTIONS BEFORE DRAININ...

Страница 29: ...atures a slight bleaching of the deepest parts of the tank a variation in the height of the edge of the spa of 6mm slight undulation on the top part due to the shrinkage of the polyester reinforcement...

Страница 30: ...pH moves away from this range the more serious the problems will become proportionally A low pH will be corrosive for the metal of the spa equipment A high pH will cause the depositing of minerals on...

Страница 31: ...ction of the environment Installation and use This warranty will be null and void for damage resulting from the operation of the spa at a temperature outside the range 1 C to 42 C the operation of the...

Отзывы: