background image

Instructions for installation and operation  -  English 

 

Installation & Use Pares - Marami - Code 10013216 - Edition 2 - 10/2011 – Page 

1.2

Installation advice 

 

ACCESS TO THE LOCATION - DELIVERY 

Ensure  the  accessibility  of  the  point  of  delivery  and  the  possibility  of  transporting  the  spa  on  a  trolley  to  its  point  of 
installation. Make sure there are no obstacles (wall, hedge, gate, steps…) and inform your dealer before delivery. 
 
Transport the spa carefully to the intended installation point. Four people are generally needed to perform this operation 
properly. 
 

UNPACKING 

Make sure you do not scratch the shell by using sharp instruments to unpack the spa. Start by puncturing the packaging in 
the middle of the spa (on the empty volume). 
 

PREPARATION OF THE SUPPORT BASE  

Make sure that the support base is properly level. 
 
If the spa is installed outside (for example on a lawn), make the support base with a stabilized bottom that will guarantee its 
stability and 

withstand a load of 400kg/m² for PARES and a load of 600kg/m² for Marami

.  

We recommend pouring a 10cm thick concrete slab. 
 
If the spa is placed on a surface that does not meet these requirements, damage to the shell, structure or the surrounds of 
the spa could occur. Any damage caused by an inadequate base is not covered by the warranty of the manufacturer. It is the 
responsibility of the owner of the spa to ensure the integrity of the support base over the course of time. 
 

SEMI-EMBEDDED

 

INSTALLATION 

 

Make sure that only the base of the spa is embedded and that the side panels remain clear. For this type of installation, we 
recommend providing a clearance of approximately 40cm and installing removable platforms (made of marine plywood or 
other material) that not only finish off the installation from an aesthetical standpoint, but which also enable the panels to be 
removed more easily in the event of after-sales service. 
 

INSTALLATION INDOORS  

In  the  case  of  installation  indoors,  it  is  necessary  to  make  allowance  for  the  fact  that  water  evaporation  can  lead  to  a  big 
increase  in  the  level  of  humidity.  Natural  or  forced  ventilation  contributes  to  maintaining  the  level  of  comfort  and 
preventing damage caused by humidity in the home. 
 
The  manufacturer  declines  any  liability  in  the  event  of  damage  due  to  an  excessive  level  of  humidity,  leaks  or  water 
overflow. We recommend you use a qualified installer.  
 

PREPARATION OF THE HYDRAULICAL CONNECTIONS 

DRAINAGE: The spa is equipped with a bottom valve with a 40 mm dia connection. To drain the water, connect a hose up to 
the  valve  or  make  a  fixed  connection  with  the  drain  pipe.  You  can  also  use  an  independent  system  to  be  fitted  with 
precaution in the spa (immersed pump or water aspirator). Before draining the water off into the public drainage system, 
check the local regulations in force. 
 
FILLING: In order to fill the spa, it is advisable to use a hose and position one end in the filtration skimmer. It is imperative to 
fill  the  spa  at  its  final  location.  Moving  a  spa  filled  with  water  is  prohibited  and  is  likely  to  cause  irreparable  damage  not 
covered by our warranty. 
 
 
 

 
 
 
 
 
 
 
 
 

Содержание Marami

Страница 1: ...Manual de uso Gebruikershandleiding Priro nik za uporabo Priru nik za upotrebu Manuale installazione Installation manual Installationshandbuch Notice d installation Manual para la instalaci n Manual d...

Страница 2: ...al treatment of the water 16 4 Use of the spa 16 4 1 Presentation of PARES 16 4 2 Presentation of MARAMI 17 4 3 PARES 18 4 4 MARAMI 18 4 5 Operation of the sand filter Marami with SpaPack only 19 4 6...

Страница 3: ...ded installation conditions in the installation manual and make sure they are properly complied with Our factory always endeavours to improve the performances of its spas For this reason it is possibl...

Страница 4: ...health In the event of use with young children or elderly people it is advisable to reduce the water temperature WARNING For use by a pregnant woman we recommend having a maximum temperature of 38 C I...

Страница 5: ...every two months or more often if necessary In order to obtain the detailed instructions for the cleaning and refitting of the cartridge For complete description refer to chapter 5 1 WARNING Change th...

Страница 6: ...STALLATION Make sure that only the base of the spa is embedded and that the side panels remain clear For this type of installation we recommend providing a clearance of approximately 40cm and installi...

Страница 7: ...e checked easily The power supply installation must comply with the provisions of the national legislation The spa must be permanently connected without any intermediate connections to the electric po...

Страница 8: ...requires the prior consent of the manufacturer Original replacement manufacturer of the pump assumes no liability for the damage and injuries caused by unauthorized replacement parts and accessories W...

Страница 9: ...there is no voltage in the circuits including the auxiliary circuits and the supplementary services 4 Wait until the rotor stops completely The above list should be considered indicative and not bind...

Страница 10: ...Installation Use Pares Marami Code 10013216 Edition 2 10 2011 Page 9 HYDRAULIC CONNECTIONS CIRCUIT PUMP 1 one speed pump CIRCUIT PUMP 2 two speed pump out 3 in 3 Pump 1 speed out 2 in 2 Pump 2 speeds...

Страница 11: ...Instructions for installation and operation English Installation Use Pares Marami Code 10013216 Edition 2 10 2011 Page 10 ELECTRIC CONNECTIONS Circulation Pumb Pump two speeds Pump one speed...

Страница 12: ...e Voltage 400 Vac Number of wires 5 Frequency 50 Hz Current consumed see attached table See also the document Electrical system safety distances and danger zones for SPA pools with hydromassage Electr...

Страница 13: ...Choose the entry point of the cable on the most suitable side and drill a cable passage of a corresponding diameter either in the base or in the surrounding panel Put in the power supply cable of 230...

Страница 14: ...er back on the electrical box 3 2 Filling the spa Only fill the spa at its final location Open all slide valves by lifting the handles and locked it by sliding the locking clips on the axes of the sli...

Страница 15: ...tly via the skimmer in order to facilitate the priming of the pumps until the water level covers all the jet spouts but without reaching the level of the lowest headrest Avoid over filling the spa as...

Страница 16: ...Tighten up the coupling and start the pump The pump should prime and air escapes for a moment through the massage nozzles Should the pump not prime quickly stop it and restart the operation Depending...

Страница 17: ...access to the spa in the absence of periods of supervision and to protect it from the wind and pollution we advise you to attach the cover with the lockable cleats supplied with it 3 5 Initial treatme...

Страница 18: ...ts position a diverter valve directs the flow from the pump to a particular sector Maintaining the diverter valve in an intermediate position between two sectors can create some turbulence in the circ...

Страница 19: ...off Waterfall Diverter valve 2 on off Therapy dream collar massage 4 4 MARAMI Diverter valve 1 on off Waterfall Diverter valve 2 on off Therapy dream collar massage Diverter valve 3 on off Foutain jet...

Страница 20: ...ncy from your filter it should be filled with silica sand with a grain size classification between 0 5mm and 0 7mm With the quantity indicated on the plate specifying the characteristics proceed as fo...

Страница 21: ...cause damage to the filter collector unit RECIRCULATE In this position the selector valve allows the water from the pump to go directly to the spa without passing through the inside of filter FILTER F...

Страница 22: ...igh cloudy water Decrease the pH The pressure rises rapidly during a filter cycle Lack of chlorine greenish coloured water Add chlorine The pump is taking in air Check for leaks in the prefilter and s...

Страница 23: ...e condition of the joint Motor turning in the wrong direction only for 3 phases pumps Invert the two phases of the feeding line The pump does not prime Hydraulic network not well dimensioning Too much...

Страница 24: ...In order to display the temperature press once on the buttons or To change the temperature all you have to do is to press again on the keys or After 5 seconds the display will return to normal provide...

Страница 25: ...enced by the presence of a level detector Chromotherapy Press the Light key to switch on the chromotherapy illumination of the spa Press a second time to switch it off It will automatically go off aft...

Страница 26: ...which corresponds to a 10h duration of the function It is possible to set the function between 0h and 24h in intervals of one hour To do that all you have to is press the or key during the display of...

Страница 27: ...conds until the time displayed starts flashing Use the keys and to set the value of the hour then press again on Clock to change the minutes Likewise use the keys and to set the minutes Lastly validat...

Страница 28: ...efore of the need to clean them BEFORE CLEANING THE FILTRATION CARTRIDGES ALWAYS SWITCH OFF THE SPA POWER SUPPLY 5 2 Draining and filling the spa WARNING READ THE FOLLOWING INSTRUCTIONS BEFORE DRAININ...

Страница 29: ...atures a slight bleaching of the deepest parts of the tank a variation in the height of the edge of the spa of 6mm slight undulation on the top part due to the shrinkage of the polyester reinforcement...

Страница 30: ...pH moves away from this range the more serious the problems will become proportionally A low pH will be corrosive for the metal of the spa equipment A high pH will cause the depositing of minerals on...

Страница 31: ...ction of the environment Installation and use This warranty will be null and void for damage resulting from the operation of the spa at a temperature outside the range 1 C to 42 C the operation of the...

Отзывы: