5
Manual #001451
Version 4.2
Control Unit
The UltraSecure 3000 is operated by a frequency converter control unit, which enables smooth ac-
celeration and deceleration of the door. The maximum opening speed is 80 in/sec depending on
door size. The door’s closing speed is approximately 24 in/sec.
Manual Operation
During maintenance work, or in the event of a power outage, the door may be opened manually by
releasing the brake via the side column mounted egress lever. The door opens partly by itself after
the brake is released, and may be opened further by manually pushing the door panel upwards.
Electric Safety Devices
The door is equipped with various safety devices, which are partly based on radio – photocell sys-
tems.
Electric safety features
The UltraSecure door utilizes a minimum of two safety features. This is comprised of safety photo-
cells and electric reversing edge.
Self-monitoring Drive Unit
The temperature of the drive unit is regulated by a thermal switch, which disrupts the power supply
of the drive unit upon overheating.
Testing the Safety Systems
Before each downward movement an internal ―self-testing‖ of the photocells and the control unit is
made automatically (Safety classification 2 according DIN EN 954-1 "Safety relevant parts of control
units"). If a fault is detected, disruption of the power supply to the control unit occurs immediately.
The safety switches work as a closing unit and are in continuous operation.
Additional Safety Systems
Depending on the kind of application it may be advisable to utilize additional sensors for safety rea-
sons. This will be especially valid for doors with frequent pedestrian traffic or doors less than 10 feet
high due to limited optical awareness of a closing door by the user.
Albany Door Systems offers various additional safety systems for fast running doors such as; motion
sensing detectors, floor loops, etc. We suggest individual consultation with an Albany Door Systems’
representative at the application site .
Содержание UltraSecure 3000
Страница 8: ...7 Manual 001451 Version 4 2 UltraSecure 3000 10 high up to 16 high ...
Страница 9: ...Rev 9 27 2009 Manual 001451 8 Operation High Speed Doors UltraSecure 3000 up to 10 high ...
Страница 26: ...25 Manual 001451 Version 4 2 ...
Страница 27: ...Rev 9 27 2009 Manual 001451 26 Operation High Speed Doors ...
Страница 28: ...27 Manual 001451 Version 4 2 ...
Страница 29: ...Rev 9 27 2009 Manual 001451 28 Operation High Speed Doors ...
Страница 36: ...35 Manual 001451 Version 4 2 ...
Страница 37: ...Rev 9 27 2009 Manual 001451 36 Operation High Speed Doors ...
Страница 38: ...37 Manual 001451 Version 4 2 ...
Страница 39: ...Rev 9 27 2009 Manual 001451 38 Operation High Speed Doors ...
Страница 40: ...39 Manual 001451 Version 4 2 ...
Страница 41: ...Rev 9 27 2009 Manual 001451 40 Operation High Speed Doors ...
Страница 42: ...41 Manual 001451 Version 4 2 ...
Страница 43: ...Rev 9 27 2009 Manual 001451 42 Operation High Speed Doors ...
Страница 44: ...1080 Maritime Drive Port Washington WI 53074 Phone 262 268 9885 Fax 262 268 9895 albanydoors com ...