Albalá Ingenieros | Manual
SEM2000C01
Name
add
ext
msk
snmp trap
Description
SFP_PRES
0x01
0x01
Y
Y
SFP module present
1=OK, 0=Fail
SFP_FAIL
0x01
0x02
Y
Y
Indicates a laser fault
0=OK,1=Fail
SFP_LOS
0x01
0x04
Y
Y
SFP loss of signal
0=OK,1=Fail
SFP_DIAG_SUPPORT
0x01
0x08
Y
N
SFP mod. supports diagnostics
1=OK, 0=Fail
P1_STATUS
0x02
0x0F
Y
Y
Ethernet connection status in Port 1
0=10Mbps HD, 1=100Mbps HD, 2=1Gbps HD, 4=10Mbps FD, 5=100Mbps FD,
6=1Gbps FD, 7=2.5Gbps, 8=No link
P2_STATUS
0x03
0x0F
Y
Y
Ethernet connection status in Port 2
0=10Mbps HD, 1=100Mbps HD, 2=1Gbps HD, 4=10Mbps FD, 5=100Mbps FD,
6=1Gbps FD, 7=2.5Gbps, 8=No link
PO_STATUS
0x04
0x0F
Y
Y
Ethernet connection status in Optical Port
0=10Mbps HD, 1=100Mbps HD, 2=1Gbps HD, 4=10Mbps FD, 5=100Mbps FD,
6=1Gbps FD, 7=2.5Gbps, 8=No link
SFP_POWER
0x05
0xFF
Y
N
Optical received power
= 2*x uW
SFP_TEMP
0x06
0xFF
Y
N
SFP module temperatura
= x ºC
BUS_UNLOCK
0x09
0x01
Y
Y
Module not locked to the 10 MHz signal from bus
0=OK,1=Fail
BUS_LOS
0x09
0x02
Y
Y
10 MHz signal not detected in bus
0=OK,1=Fail
19
Содержание SEM2000C01
Страница 2: ...SEM2000C01 ...
Страница 4: ...SEM2000C01 ...
Страница 7: ...Albalá Ingenieros Manual SEM2000C01 1 3 Block diagram 7 ...
Страница 8: ...Albalá Ingenieros Manual SEM2000C01 SEM2000C01 8 ...
Страница 10: ...Albalá Ingenieros Manual SEM2000C01 SEM2000C01 10 ...
Страница 20: ...Albalá Ingenieros Manual SEM2000C01 SEM2000C01 20 ...
Страница 22: ...Albalá Ingenieros Manual SEM2000C01 SEM2000C01 22 ...
Страница 24: ...Albalá Ingenieros Manual SEM2000C01 SEM2000C01 24 ...
Страница 26: ...Albalá Ingenieros S A Medea 4 28037 Madrid Spain 34 913274453 www albalaing com info albalaing com ...