background image

Albalá Ingenieros | Manual 

IMB2000C01

TTL_TX

0x08

0xFF

Y

N

Time To Life for transmitted packets
= x

TX_SR_PORT

0x09

0xFFFF

Y

N

Source port
= x

OFFSET_TIME_RX

0x0B

0xFF

N

N

Margin of safety before inserting samples in buffer to avoid overflow
= x samples

ETH_MODE_1

0x0C

0x07

Y

N

Allows selecting the Ethernet operating mode
7=Auto, 0=10Mbps HD, 4=10Mbps FD, 1=100Mbps HD, 5=100Mbps FD,
2=1Gbps HD, 6=1Gbps FD

SPEED_FORCE_1

0x0C

0x40

Y

N

Allows selecting if the speed/mode is forced or announced for autonegotiation
0=Announced, 1=Forced

ADDRESS_1_2_EN

0x0C

0x80

Y

N

Interface 2 enable
0=No, 1=Yes

ETH_MODE_2

0x0D

0x07

Y

N

Allows selecting the Ethernet operating mode
7=Auto, 0=10Mbps HD, 4=10Mbps FD, 1=100Mbps HD, 5=100Mbps FD,
2=1Gbps HD, 6=1Gbps FD

SPEED_FORCE_2

0x0D

0x40

Y

N

Allows selecting if the speed/mode is forced or announced for autonegotiation
0=Announced, 1=Forced

ADDRESS_2_2_EN

0x0D

0x80

Y

N

Interface 2 enable
0=No, 1=Yes

RAM

Name

add

ext

msk

snmp trap

Description

LOCAL_IP_GWAY_3

0x05

0xFF

Y

N

Gateway IP address (3)
= x

LOCAL_IP_GWAY_2

0x06

0xFF

Y

N

Gateway IP address (2)
= x

LOCAL_IP_GWAY_1

0x07

0xFF

Y

N

Gateway IP address (1)
= x

LOCAL_IP_GWAY_0

0x08

0xFF

Y

N

Gateway IP address (0)
= x

SLOT1_M2S_INS

0x00

0x0010

0x01

Y

N

Backplane slot 1 M2S insert
0=Disabled, 1=Enabled

SLOT2_M2S_INS

0x00

0x0010

0x02

Y

N

Backplane slot 2 M2S insert
0=Disabled, 1=Enabled

SLOT3_M2S_INS

0x00

0x0010

0x04

Y

N

Backplane slot 3 M2S insert
0=Disabled, 1=Enabled

SLOT4_M2S_INS

0x00

0x0010

0x08

Y

N

Backplane slot 4 M2S insert
0=Disabled, 1=Enabled

SLOT5_M2S_INS

0x00

0x0010

0x10

Y

N

Backplane slot 5 M2S insert
0=Disabled, 1=Enabled

SLOT6_M2S_INS

0x00

0x0010

0x20

Y

N

Backplane slot 6 M2S insert
0=Disabled, 1=Enabled

SLOT7_M2S_INS

0x00

0x0010

0x40

Y

N

Backplane slot 7 M2S insert
0=Disabled, 1=Enabled

SLOT8_M2S_INS

0x00

0x0010

0x80

Y

N

Backplane slot 8 M2S insert
0=Disabled, 1=Enabled

PROFILE

0x01

0x0010

0x0F

Y

N

Allows loading default values of a PTP profile
0=General, 1=SMPTE ST 2059, 2=AES67, 3=IEEE 802.1
AS,4=SMPTE/AES,15=Custom

DOMAIN_NUMBER

0x02

0x0010

0xFF

Y

N

Allows selecting the Domanin number attribute of the local clock
= x

LOG_ANNOUNCE_INT

0x03

0x0010

0xFF

Y

N

Allows selecting the mean interval between Announce messages
= 2^x s

LOG_SYNC_INT

0x04

0x0010

0xFF

Y

N

Allows selecting the mean interval between Sync messages
= 2^x s

LOG_MIN_D_R_INT

0x05

0x0010

0xFF

Y

N

Allows selecting the minimum mean interval between Delay_Req messages
= 2^x s

STREAM_OK_1

0x00

0x0020

0x01

Y

N

AES67 stream 1 received
1=OK, 0=Fail

BUFFER_UNDERF_1

0x00

0x0020

0x02

Y

N

Buffer underflow
0=OK,1=Fail

BUFFER_OVERF_1

0x00

0x0020

0x04

Y

N

Buffer_overflow/TS error
0=OK,1=Fail

MALFORMED_PCK_1

0x00

0x0020

0x20

Y

N

Malformed packets
0=OK,1=Fail

RX_FAIL_1

0x00

0x0020

0x40

Y

N

RX1 stream fail
0=OK,1=Fail

RX_1_PCK_RATE

0x01

0x0020

0xFFFF

Y

N

IP packet rate
= x packets/s

22

Содержание IMB2000C01

Страница 1: ...IMB2000C01 256X192 CHANNELS MULTIFORMAT AUDIO MATRIX Version 1 0 Albalá Ingenieros S A Medea 4 28037 Madrid Spain 09 October 2020 Albalá Ingenieros S A All rights reserved ...

Страница 2: ...IMB2000C01 ...

Страница 3: ... frame 12 3 5 Interconnection 12 3 5 1 Ethernet connections 13 3 5 2 MADI audio electrical connections 13 4 OPERATION 15 4 1 Front panel description 15 4 2 Functional description 16 4 2 1 MADI encoder decoder CODEC 16 4 2 2 AES67 transmitter 16 4 2 3 AES67 receiver 17 4 2 4 AUDIOFLEX bus matrix 17 4 2 5 Synchronization 18 4 2 6 Interconnection matrix 19 4 3 Presets 19 4 4 Module remote control and...

Страница 4: ...IMB2000C01 ...

Страница 5: ...y two lines M2S Master to Slave and S2M Slave to Master that interconnect all the slots of the frame Each of the two lines can multiplex up to 64 audio channels sampled at 24 bits and 48 kHz grouped into eight time slots of eight audio channels each The IMB2000C01 module has been designed to operate together with the ADB2008C01 DAB2008C01 DDB2008C01 and DEB2008C01 modules They use the two lines of...

Страница 6: ...B2008C01 takes eight channels of audio from the bus and converts them to analog DDB2008C01 permits extraction of eight pairs of audio from the bus and transmits them in eight AES EBU digital audio streams or receives eight streams of AES EBU digital audio and sends eight audio pairs to the bus The AES EBU digital audio streams that are received and transmitted must be synchronized to the audio in ...

Страница 7: ...Albalá Ingenieros Manual IMB2000C01 1 3 Block diagram 7 ...

Страница 8: ...Albalá Ingenieros Manual IMB2000C01 IMB2000C01 8 ...

Страница 9: ...r RJ45 Encoding and electrical characteristics 1000BASE T According to IEEE std 802 3 40 standard 100BASE T According to IEEE std 802 3 24 25 standard 10BASE T According to IEEE std 802 3 13 14 standard Operating modes Auto Negotiation speed full duplex half duplex Supported protocols IP ARP ICMP TCP UDP RTP IGPM v2 y v3 VLAN NTP PTP IEEE std 1588 TELNET FTP HTTP Audio video transport protocols Ac...

Страница 10: ...Albalá Ingenieros Manual IMB2000C01 IMB2000C01 10 ...

Страница 11: ...arth connection Never use extension cords that do not have protective earthing connection The lack of an effective electrical connection between the ground pin in the mains input connector of the equipment and the protective earth of the electrical power distribution can cause serious harm All modules of the Albalá Ingenieros TL2000 terminal line can be hot plugged or unplugged without suffering a...

Страница 12: ...rame 1 Remove the blank panel covering the front of the empty slot chosen for installing the IMB2000C01 in the mounting frame 2 Insert the IMB2000C01 module into the front of the mounting frame The edges of the card slide into two plastic guides inside the mounting frame 3 Secure the module to the mounting frame using the two front screws After these steps the module is ready to be connected to ot...

Страница 13: ...er 5e or 6 in order to guarantee proper operation at 1 Gbps 3 5 2 MADI audio electrical connections The electrical connectors for MADI audio are all BNC type The following are a series of recommendations to keep in mind when making these electrical signal connections The BNC connectors used on the cables should be able to handle high frequency digital audio signals and it is highly recommended tha...

Страница 14: ...Albalá Ingenieros Manual IMB2000C01 IMB2000C01 14 ...

Страница 15: ...tration Front panel of the IMB2000C01 In addition to the connectors previously described in the Interconnection section the front panel includes the following indicators and controls MADI This LED lights up in green OK to indicate that a MADI signal with the correct format is being received This LED lights up in red FAIL when either no MADI signal is being received or if the format is incorrect If...

Страница 16: ...ncoder decoder CODEC The MADI decoder detects the presence of signal at the MADI input connector indicates the number of channels contained in the stream 56 or 64 if the format of the stream received conforms to AES10 and routs the stream to the interconnection matrix The encoder receives the audio channels to be transmitted from among the 256 that are received via AES67 MADI or the S2M line of th...

Страница 17: ...a module installed in the UR2000 frame that acts as the bus master This is normally the IMB2000C01 which inserts a header aligned in the M2S line and a reference signal onto the internal 13 5 MHz synchronization bus When the IMB2000C01 is installed in a mounting frame it always acts as the bus master In addition to generating the header and the reference signal it inserts audio into the eight time...

Страница 18: ...the LAN over which the synchronization is performed must provide sufficient quality of service for synchronization To achieve this it is recommended that the devices forming the LAN be capable of operating as Transparent Clocks or Boundary Clocks The IMB2000C01 includes predefined profiles for its most common applications and a customized profile can also be defined with the most relevant protocol...

Страница 19: ...slots by eight channels per slot MADI RX 64 channels AES67 RX 16 streams by eight channels per stream Outputs AUDIOFLEX M2S Eight time slots by eight channels per slot MADI TX 64 channels AES67 TX 16 streams by eight channels per stream 4 3 Presets The IMB2000C01 provides 16 presets what are stored in non volatile memory and can be recalled at any time via remote control with a control keyboard or...

Страница 20: ...le an optional TL2000 family remote communications controller must be installed in the mounting frame The main function of the communications control module is to interface between a 10 100 Ethernet port and the internal bus of the mounting frame The following illustration shows the most common control situations from a computer or control panel via Ethernet Certain communications control modules ...

Страница 21: ... in the CONTROL or RAM sections is stored in volatile memory Any modifications to the parameters will be lost when the module power supply is disconnected unless the EEPROM Save button within the software has been pressed The STATUS section parameters are read only and cannot be modified The EEPROM section parameters are rarely used and are stored directly in non volatile memory The parameters tha...

Страница 22: ...t 2 M2S insert 0 Disabled 1 Enabled SLOT3_M2S_INS 0x00 0x0010 0x04 Y N Backplane slot 3 M2S insert 0 Disabled 1 Enabled SLOT4_M2S_INS 0x00 0x0010 0x08 Y N Backplane slot 4 M2S insert 0 Disabled 1 Enabled SLOT5_M2S_INS 0x00 0x0010 0x10 Y N Backplane slot 5 M2S insert 0 Disabled 1 Enabled SLOT6_M2S_INS 0x00 0x0010 0x20 Y N Backplane slot 6 M2S insert 0 Disabled 1 Enabled SLOT7_M2S_INS 0x00 0x0010 0x...

Страница 23: ...erflow 0 OK 1 Fail BUFFER_OVERF_3 0x00 0x0040 0x04 Y N Buffer_overflow TS error 0 OK 1 Fail MALFORMED_PCK_3 0x00 0x0040 0x20 Y N Malformed packets 0 OK 1 Fail RX_FAIL_3 0x00 0x0040 0x40 Y N RX3 stream fail 0 OK 1 Fail RX_3_PCK_RATE 0x01 0x0040 0xFFFF Y N IP packet rate x packets s RX_3_LOST_IP_PK 0x03 0x0040 0xFFFF Y N Lost IP packets rate x packets RX_3_DUP_IP_PCK 0x05 0x0040 0xFFFF Y N Duplicate...

Страница 24: ...ate x packets RX_6_DUP_IP_PCK 0x05 0x0070 0xFFFF Y N Duplicated IP packets rate x packets MAX_BUFF_LEV_6 0x07 0x0070 0xFFFF Y N Maximum buffer level 0 01 x MIN_BUFF_LEV_6 0x09 0x0070 0xFFFF Y N Minimum buffer level 0 01 x STREAM_OK_7 0x00 0x0080 0x01 Y N AES67 stream 7 received 1 OK 0 Fail BUFFER_UNDERF_7 0x00 0x0080 0x02 Y N Buffer underflow 0 OK 1 Fail BUFFER_OVERF_7 0x00 0x0080 0x04 Y N Buffer_...

Страница 25: ...K 1 Fail BUFFER_OVERF_10 0x00 0x00B0 0x04 Y N Buffer_overflow TS error 0 OK 1 Fail MALFORMED_PCK_10 0x00 0x00B0 0x20 Y N Malformed packets 0 OK 1 Fail RX_FAIL_10 0x00 0x00B0 0x40 Y N RX10 stream fail 0 OK 1 Fail RX_10_PCK_RATE 0x01 0x00B0 0xFFFF Y N IP packet rate x packets s RX_10_LOST_IP_PK 0x03 0x00B0 0xFFFF Y N Lost IP packets rate x packets RX_10_DUP_IP_PCK 0x05 0x00B0 0xFFFF Y N Duplicated I...

Страница 26: ...e x packets RX_13_DUP_IP_PCK 0x05 0x00E0 0xFFFF Y N Duplicated IP packets rate x packets MAX_BUFF_LEV_13 0x07 0x00E0 0xFFFF Y N Maximum buffer level 0 01 x MIN_BUFF_LEV_13 0x09 0x00E0 0xFFFF Y N Minimum buffer level 0 01 x STREAM_OK_14 0x00 0x00F0 0x01 Y N AES67 stream 14 received 1 OK 0 Fail BUFFER_UNDERF_14 0x00 0x00F0 0x02 Y N Buffer underflow 0 OK 1 Fail BUFFER_OVERF_14 0x00 0x00F0 0x04 Y N Bu...

Страница 27: ...d EN_BUS_REF_TX 0x00 0x0120 0x02 Y N Sends reference to rear bus 0 No 1 Yes SLOT1_S2M_PRES 0x01 0x0120 0x01 Y N Slot1 S2M bus presence 0 Inactive 1 Active SLOT2_S2M_PRES 0x01 0x0120 0x02 Y N Slot2 S2M bus presence 0 Inactive 1 Active SLOT3_S2M_PRES 0x01 0x0120 0x04 Y N Slot3 S2M bus presence 0 Inactive 1 Active SLOT4_S2M_PRES 0x01 0x0120 0x08 Y N Slot4 S2M bus presence 0 Inactive 1 Active SLOT5_S2...

Страница 28: ...D_2 0x0B 0x0140 0xFF Y N IP address 2 x LOCAL_IP_3_ADD_1 0x0C 0x0140 0xFF Y N IP address 1 x LOCAL_IP__ADD_0 0x0D 0x0140 0xFF Y N IP address 0 x LOCAL_IP_3_MSK_3 0x0E 0x0140 0xFF Y N IP mask 3 x LOCAL_IP_3_MSK_2 0x0F 0x0140 0xFF Y N IP mask 2 x LOCAL_IP_3_MSK_1 0x00 0x0150 0xFF Y N IP mask 1 x LOCAL_IP_3_MSK_0 0x01 0x0150 0xFF Y N IP mask 0 x VLAN_3_ENABLE 0x02 0x0150 0x10 Y N VLAN Enable 0 No 1 Y...

Страница 29: ...K 0 Fail TX_WORKIN_STAT_5 0x06 0x02 Y N TX 5 transmitting 1 OK 0 Fail ARP_VALID_5 0x06 0x04 Y N TX 5 valid ARP response Unicast mode 1 OK 0 Fail ICMP_ERROR_5 0x06 0x08 Y N TX 5 destination unreachable ICMP destination unrechable packets received 1 OK 0 Fail TX_WORKIN_STAT_6 0x07 0x02 Y N TX 6 transmitting 1 OK 0 Fail ARP_VALID_6 0x07 0x04 Y N TX 6 valid ARP response Unicast mode 1 OK 0 Fail ICMP_E...

Страница 30: ... N Ethernet conection status 8 10Mbps 9 100Mbps 10 1Gbps No link SYSTEM_1 0x18 0x0C Y N Ethernet conection system 3 Full Duplex 2 Half Duplex No link LINK_2 0x19 0x0B Y N Ethernet conection status 8 10Mbps 9 100Mbps 10 1Gbps No link SYSTEM_2 0x19 0x0C Y N Ethernet conection system 3 Full Duplex 2 Half Duplex No link 30 ...

Страница 31: ... also used as a framework to transmit digital signals that may or may not be audio with linear PCM encoding The physical interface defined by the original AES EBU standard was a 110 ohm balanced line The AES3 id standard later defined the physical interface as a 75 ohm coaxial cable BNC Bayonet Neill Concelman connector GNSS Global Navigation Satellite System Satellite navigation system with globa...

Страница 32: ...Albalá Ingenieros Manual IMB2000C01 IMB2000C01 32 ...

Страница 33: ...cations of networks High performance streaming audio over IP interoperability See also EBU Tech 3326 EBU Tech 3329 IEEE std 1588 2008 IEEE Standard for a Precision Clock Synchronization Protocol for Networked Measurement and Control Systems See also AES67 IEEE std 802 1as SMPTE ST 2059 2 IEEE std 802 3 2015 Carrier Sense Multiple Access with Collision Detection CSMA CD Access Method and Physical L...

Страница 34: ...Albalá Ingenieros Manual IMB2000C01 IMB2000C01 34 ...

Страница 35: ...Albalá Ingenieros Manual IMB2000C01 7 VERSIONS Ver Date Description 0 0 06 10 2020 Preliminary Version 1 0 09 10 2020 First version ...

Страница 36: ...Albalá Ingenieros S A Medea 4 28037 Madrid Spain 34 913274453 www albalaing com info albalaing com ...

Отзывы: