background image

Operation

   

      

1.PC:Turn on"PC"function,the meter &PC 
          application program communication. When 
          turn on "PC" function ,The auto power off 
          will be canceled, and the power off will be 
          canceled, too. 

   

  
  

T1

TYPE:K

T1

TYPE:K

T1

TYPE:K

T1

TYPE:K

T1

TYPE:K

PC

REC

REC

OU

PC

REC

PC

REC

25

25

25

25

25

 

 

 

 

 

step1

press

step1

press

step2
press

step2

press

A

A

A

A

back to main display

back to main display

Memory is filled

2.REC:  Turn on REC function,the reading value
                of meter, according to transmitting the 
                settlement of interval time,will write
                down in the memory real time.Can write
                down 10000 records at most. When turn
                on "REC" function,the auto power off 
                will be canceled, and the power off  will
                be canceled,too.When the memory is 
                filled, the display will appeared"ou"
                word.For Data Logger models.
               

1

2

Operation 

   

   

   

   

   

   

   

press

last number

 surplus space

time

date

date

year

press

press

press

press

T1
TYPE:K

T1
TYPE:K

T1
TYPE:K

25

25

1293

1293

25

30

2205

2205

2205

2205

BYTE

BYTE

2004

2004

22:05

22:05

40

1000

1000

50

 

 

 

T2

T4

h:m

h:m

T3

CALL

CALL

y

y

CALL

CALL

SHIFT

SHIFT

step1

step2

step3

step4

step5

back to step1

3.CALL:Can inquire that the data of every 
   channel, can also inquire about the surplus 
   space of the memory. For Data Logger models. 
   Each time entering to inquire data by the last. 
   When turn on "CALL" function, the auto
   power off will be canceled.   
               

CALL

SHIFT

SHIFT

AA

A.Use    ,    key to choose "channel".
B.Use    ,    key to choose "number".Hold     or
    key above 1 second, the readout rate will be
    added. About 50 numbers/sec.  

Содержание TM-7 Series

Страница 1: ...ts Introduction Features General specifications Electrical specifications Operation Names of parts Battery replacement Caution 1 2 3 4 5 6 16 17 YC 747UD PC TM 7XX series thermometer K J T E R S N Typ...

Страница 2: ...ed into 48 modes refer to the table below for a concise summary of subtle distinctions in their designed functions 2 1 The maximum displays for four temp values 2 Resolution 0 1 0 1 1 1 3 Swift respon...

Страница 3: ...ture and Humidity 20 60 4 140 0 80 RH 11 Dimension 164x76x32mm LxWxH 12 Weight Approx 415g include batteries 13 Accessories A DC 1 5V UM 4 4pcs B Housing 1pcs C K type thermocouple wire single channel...

Страница 4: ...selection key Press the key to sequentially alternate the three temp unit of and K 3 HOLD The readout hold function key Press the HOLD key a HOLD icon will display on the LCD and the readout held in p...

Страница 5: ...TYPE K T1 TYPE K 25 25 REL REL REL step1 press step2 press 0 0 original temp input temp Save25 T1 TYPE K T1 TYPE K 25 30 REL REL 0 0 5 0 30 25 5 8 Operation 7 CHAN every input temp value changed to m...

Страница 6: ...d will flicker for the chosen type C To confirm it then press SHIFT key The type became to J type Operation 9 COUNT The count time setting function key The max count time is 99 hours and 59 minutes 10...

Страница 7: ...T3 T3 T3 step1 step2 step3 step4 HOLD HOLD SHIFT SHIFT SHIFT 12 Operation press press press press T1 TYPE K SHIFT T1 TYPE K T1 TYPE K SHIFT T1 TYPE K 25 25 25 25 30 30 30 30 40 40 40 40 50 50 50 50 T2...

Страница 8: ...he adjustable word Back to main display 14 Operation press press press press press T1 TYPE K SHIFT T1 TYPE K 25 12 01 12 01 12 01 25 30 3003 3003 3003 2004 2004 2004 30 40 40 50 50 T2 T2 T4 y y y T4 T...

Страница 9: ...1 5V battery at once to ensure the test accuracy 2 Remove the battery cover by one screwdriver 3 Replace the old battery with four new 1 5V batteries and lock the battery cover 4 Prior to replacing t...

Страница 10: ...a temperature gauge that is not working properly for this may result in physical harms send for repair service at once 6 Please DO NOT attempt to operate the temperature gauge in the around sites whe...

Страница 11: ...canceled and the power off will be canceled too When the memory is filled the display will appeared ou word For Data Logger models 1 2 Operation press last number surplus space time date date year pr...

Страница 12: ...Enter and show settlement value last time for the second time after For USB or Data Logger models T1 TYPE K 25 30 40 50 T2 T4 T3 SHIFT SHIFT A A 4 6 carry out the record interval setting The biggest s...

Страница 13: ...NTV PC INTV PC INTV back to main display The flashing number represents adjustable number SHIFT SHIFT SHIFT SHIFT A A A A 7 m s m s m s Office Jl Radin Inten II No 62 Duren Sawit Jakarta 13440 Indones...

Отзывы: