Keypad Low Battery

The keypad communicates a low battery condition to the panel through 
the low battery bit set in the KEY PRESS message.  If the battery is low, 
on keypad wake up the keypad will indicate a fault condition (beep and 
fl ash the LED red once) while briefl y displaying on the LCD a low battery 
prompt, instead of the usual keypad ready message:

PLEASE REPLACE

KEYPAD BATTERIES

Once the low battery condition occurs, key presses will also be annunciated 
by a double click instead of the usual single click.

If the battery condition continues to deteriorate to marginal levels, the 
keypad may take measures to conserve power by limiting backlight 
operation or reducing inactivity timeout before going into standby. 

Communication Failure

If the keypad is unable to communicate with the panel during operation 
and receives a RETRY FAIL message from its transceiver, it will indicate 
a fault condition (beep and fl ash the LED red once) and display a prompt 
to the user:

PLEASE RE-ENTER

KEY SEQUENCE

If the keypad is active and the condition persists for more than 15 
seconds, the keypad will repeat the fault indication.  This will recur until 
the communication is restored or until the keypad times out and goes into 
standby mode.

Piezo Annunciator

The keypad has a piezo sounder to indicate system conditions to the user. 
A short beep will occur every time a key is pressed.  In addition, commands 
from the panel will instruct the sounder to operate in a specifi ed pattern.

Bicolor LED

The keypad has a red / green LED controlled by commands from the panel.

Содержание DXS-14

Страница 1: ...ns ALARMFORCE AlarmForce Industries Inc 675 Garyray Drive Toronto ON M9L 1R2 Canada PRINTER S INSTRUCTIONS INSTR INSTL DXS 14 LINEAR P N 233766 X3 INK BLACK MATERIAL 20 LB MEAD BOND SIZE 5 500 X 8 500...

Страница 2: ...re being generated If tones are required then the keypad will enter standby mode only when tone cycles have been completed The keypad can be wall mounted and is powered by four 1 5 volt AA batteries T...

Страница 3: ...ur A clock key is provided for local keypad operation and configuration Pressing the clock key once displays the keypad status and time and date on the LCD Pressing and holding the clock key for more...

Страница 4: ...HIME A long press key press message is sent to the panel at this time At this point the panel may respond to disallow the operation of special commands if special commands are disabled The keypad will...

Страница 5: ...last bypassed zone listed will cause the keypad to send the key press to the panel which in turn will provide a DISPLAY ARM message packet for the next event in the panel s arming history When viewing...

Страница 6: ...inactivity timeout before going into standby Communication Failure If the keypad is unable to communicate with the panel during operation and receives a RETRY FAIL message from its transceiver it wil...

Страница 7: ...e 10 C to 60 C Antenna 2 insulated wires approximately 6 5 MECHANICAL Material Cases molded in ABS plastic Mounting Wall mounting Battery Access 4 AA Batteries are replaceable by removing keypad from...

Страница 8: ...radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or...

Отзывы: