background image

time and effort.  In DL-Windows, Groups are controlled via sched-
ules, and a typical example involves enabling or disabling a 
Group at a certain time.  

Note:

  Groups may only be added or 

changed via DL-Windows.   

 
 

What are Function Cards? 

There are three ways to program the PL3000 lock:  (1) Using DL-
Windows; (2) Using a pre-programmed AL-DTM module; and (3) 
Using proximity cards as "Function Cards" at first power-up.  The 
Function cards are simply 9 standard proximity cards labeled one 
through nine, and after being presented (enrolled into) the 
PL3000 lock (see page 12 for procedure), each card will then be 
able to perform a specific function, as follows: 
 

Card 1        Initiates PC communications (User 298). 
Card 2        Initiates AL-DTM communications (User 299). 
Card 3        Initiates entry of new proximity cards starting at 

User 301 (and ending at User 2000). 

Card 4        Initiates removal of next presented proximity 

card. 

Card 5        Toggles 

Passage Mode.

 

Card 6        Initiates AL-IR1 printing with Time, Date, Ver-

sion Number and Audit Trail Log. 

Card 7        Toggles 

Total User Lockout

 mode. 

Card 8        Enables Function Card #9 (User 297). 
Card 9        The 

Service Card

, allowing access one-time-

only (User 300). 

 

It is still possible to perform all lock programming via DL-
Windows or via an AL-DTM module, with or without ever en-
rolling the Function Cards at first start up.  

However, it is 

highly recommended that Function Cards be enrolled even if you 
do not intend to use them--because once the lock is in operation, 
you may 

not 

enroll Function Cards without first performing a "cold 

start" (removing all programming and thus re-loading all original 
factory default settings).  See Glossary entry for "Default" on page 
26 for more information.   
 

Note: 

 If the Function Card enrollment process is bypassed and 

the AL-DTM is used to move programming data from the PC to 
the PL3000 lock, the PL3000 lock 

will always default to Door 

#1

.  In addition, the current AL-DTM allows the programming of 

specific door numbers (and their associated data files), regardless 
of the door number sent to the AL-DTM by the PL3000 lock.  See 
page 16 for more information.   
 

IMPORTANT NOTE:   

When programming is sent from DL-Windows (or an AL-DTM) to 
the lock, Function Cards 1, 2, 8, and 9 will be overwritten with the 
existing data in DL-Windows for the User Locations 298, 299, 297 
and 300, respectively.  Therefore, to continue to use Function 
Cards 1, 2, 8 and 9 that were enrolled at startup with DL-
Windows, 

be sure to enroll the same Function Cards 1, 2, 8 

and 9 used at startup into the correct locations within DL-
Windows.  

 

 
In addition, Function Cards 3 through 7 are not recognized by DL-
Windows.  Therefore, DL-Windows will not send the data for 
Function Cards 3-7 to the AL-DTM, nor will the AL-DTM be able 
to send this Function Card data to the PL3000 lock.  Accordingly, 
Function Cards are designed to be used for limited-use installa-
tions where DL-Windows will not be used (or is not available).  If 
DL-Windows is used, Function Cards 3-7 will most likely never be 

used.  The advantage of the PL3000 lock is that it is designed to 
be flexible for any application.   
 

Who are 

Users 297-300

Proximity cards assigned to User Numbers 297, 298, 299 and 
300 have special abilities, as follows: 

 

User 297 (Function Card #8):  

Quick Enable User 300

 

Function Card #8 (assigned to User 297) possesses the unique 
ability to enable Function Card #9 (assigned to User 300).  
When Function Card #8 is presented to the lock, User 300 is 
enabled, allowing Function Card #9 to unlock the PL3000 (for 
one time).  Once used, Function Card #9 (User 300) becomes 
disabled. 

 

For example, you wish to allow one-time access to a temporary 
worker.  Simply present Function Card #8 to the lock and give 
Function Card #9 to your temporary worker.  Later, when the 
temporary worker presents Function Card #9 to the lock, the 
PL3000 unlocks and allows access (for one time only).  If the 
temporary worker re-presents his card, access will be denied.  
Later, if you wish to grant the temporary worker re-access, sim-
ply re-present Function Card #8 to the lock and Function Card 
#9 will be re-enabled (again for one time only).   
 

User 298 (Function Card #1):  

Quick PC Communications Card

  

Presenting the proximity card for User 298 (Function Card #1) 
initiates data to be sent to or from the lock and DL-Windows.  
Therefore, an AL-PCI2 cable with a PC is required.   
 

User 299 (Function Card #2):  

AL-DTM Data Transfer Card

 

Presenting the card assigned to User 299 (Function Card #2) will 
initiate data transfer with the AL-DTM.  An AL-PCI2 cable and an 
AL-DTM (first programmed by the computer via DL-Windows) is 
required.  

Note:

  This card does not unlock the lock (does not 

allow access).   
 

User 300 (Function Card #9):  

One-Time-Only Service Card

 

This is a 

One-Time Only Service User Card

 (Function Card #9) 

enabled by the proximity card assigned to User 297 (Function 
Card #8).  For example, User 300 Function Card #9) is some-
times used for guard tour duties.  See User 297:  Quick Enable 
User 300 above.   
 
 

What is 

DL-Windows

?

 

DL-Windows is a computer program that allows you to program 
your ALARM LOCK T3 Security Lock.  You do not need DL-
Windows to program your lock, but it makes programming much 
faster and easier.  With DL-Windows, you can quickly create Lock 
Programs (programs that make the lock perform its many func-
tions) add multiple Users (who have access), add ProxCards

®

 and 

ProxKey

®

 keyfobs, retrieve event logs, and create Schedules.  The 

benefit of DL-Windows is that it allows you to set up all lock pro-
gramming in advance (on your computer), and then later send the 
information to the locks at your convenience.  For more informa-
tion, see OI237.   

Terminology Used in this Manual (cont'd) 

Содержание Trilogy PL3000

Страница 1: ...ING SOFTWARE PL Trilogy Series Stand Alone Access Control System with ProxCard Access WI1280A 5 07 PL3000 HID HID CORPORATION PROXCARD PROXKEY KEYFOB AL IR1 PRINTER AL DTM DATA TRANSFER MODULE 345 Bayview Avenue Amityville New York 11701 For Sales and Repairs 1 800 ALA LOCK For Technical Service 1 800 645 9440 ...

Страница 2: ... and 3 use 9 proximity cards as Function Cards when lock is first powered up In addition data can be retrieved from the lock in one of three ways 1 through an infrared printer 2 directly from the lock to the PC or 3 through an AL DTM to your PC Note ProxCard and ProxKey are trademarks of the HID Corporation PL SERIES LOCKS PL3000 PL Series Lock Features 3 Supported Products 4 Lock Design Overview ...

Страница 3: ...led Events Automated Unlock Lock Enable Disable Users Enable Disable Groups Real time clock and calendar User Access Methods ProxCard and ProxKey Keyfob Batch Enroll Quickly and easily enroll multiple ProxCards and ProxKey keyfobs without the use of a PC Note ProxCards and ProxKey Keyfobs both function identically Keyfobs can be substituted for all references to the ProxCard in this manual User Fe...

Страница 4: ...ug You can also use this cable to transfer the Lock Program from your lock to an AL PRE DB9 to DB9 Serial Cable Enroll ProxCards quickly into DL Windows then transfer this new ProxCard data from the computer to the AL PRE via this 9 pin DB9 to DB9 serial cable Once the data is in the AL PRE you can transfer the data to the lock via the double ended mini banana plug see above thus avoiding the need...

Страница 5: ...ith the computer program DL Windows installed 2 By a direct connection to an AL DTM module allowing the transfer of lock data from the computer to the lock 3 By using 9 proximity cards provided as Function Cards when lock is first powered up It is recommended that DL Windows be used when programming your PL3000 lock especially if you intend to enroll many User Cards DL Windows can always be used a...

Страница 6: ...ilding in which the lock is installed who will probably wish to have total authority to make changes The PL Series locks can hold up to 1999 Users in its programming memory using DL Windows and 1700 with the Function Cards see Function Card definition below What is a Programming Level With other Trilogy locks that possess keypads such as the PDL3000 ETPDL etc the Programming Level defines the rang...

Страница 7: ... the AL DTM be able to send this Function Card data to the PL3000 lock Accordingly Function Cards are designed to be used for limited use installa tions where DL Windows will not be used or is not available If DL Windows is used Function Cards 3 7 will most likely never be used The advantage of the PL3000 lock is that it is designed to be flexible for any application Who are Users 297 300 Proximit...

Страница 8: ...ows User 299 is a Non Pass Code does not unlock the PL3000 This is the only code that will initiate data transfer with the AL DTM NOTES Default User Numbers The table below displays a graphical representation of how the internal memory of the PL3000 lock is organized The default settings are the original settings that were set at the factory the lock s original factory condition when the lock was ...

Страница 9: ...ard exists in memory but dis abled Low Battery 4 second continu ous beep See page 11 before changing bat teries User Card Error RED Flash Sequence of 7 beeps repeated 4 times Non fatal memory or clock error has been detected Under this condition unexpected operation is possible Remove power and re start LED and Sounder Indicators The PL Series locks provide visual and audible feedback With a fully...

Страница 10: ...L DTM via an AL PCI2 cable then transfer the program from the AL DTM to the lock s via a double ended mini banana plug The hand held AL DTM is useful because you do not have to transport or find electricity for your computer Data can also flow in reverse from the lock through the AL DTM back to the computer for examination You must always use Function Card 2 to send and receive data us ing DL Wind...

Страница 11: ...alid card is presented and the batteries are weak the sounder will sound for 4 seconds Always replace weak batter ies five 5 AA size 1 5 volt alkaline as soon as possible 1 At the back of the lock remove the screw at the bottom of the lock housing and remove the cover 2 Pull out the battery pack and quickly replace all 5 batteries within 1 minute 3 If you do not hear the 3 beeps when power is re a...

Страница 12: ...h 9 Each time a new Function Card is presented the lock LED will flash green twice with two beeps indicating the card was enrolled successfully Note You do not have to present all 9 Function Cards For example if you wish only to use Function Cards 1 through 3 simply allow the allow the lock 30 seconds to timeout after presenting Function Card 3 14 After the 9th Function card is presented the lock ...

Страница 13: ...in the battery pack with attention to the correct polarity as indicated inside the plastic battery pack housing 3 With battery power disconnected short the two white wires Remote Input wires together for 10 seconds to ensure discharge of all capacitors After 10 seconds remove the short 4 Plug in the provided male shunt connector into the yellow wire female connector 5 With shunt connector connecte...

Страница 14: ...ge Mode Door is unlocked all Users are allowed free access through the door 20 Card 6 Initiates AL IR1 printing with Time Date Version Number and Au dit Trail Log 21 Card 7 Toggles Total User Lockout mode Disables all card input func tions Note A lock in Passage Mode will remain in Passage Mode 22 Card 8 Enables and resets Function Card 9 User 297 23 Card 9 The Service Card allowing access one tim...

Страница 15: ... Send to Lock screen will indicate the data transfer The Model Type and Firmware Version will be displayed on the Send to Lock screen 8 After the data transfer is complete Send To Lock Successful will be displayed in the Status Window lower left hand corner of the Send to Lock screen 9 At the end of the transfer process the PL3000 will sound a series of beeps You can disconnect the AL PCI2 ca ble ...

Страница 16: ...necting the AL PCI2 cable or AL PRE to the AL DTM 2 Connect the AL DTM to the Lock Connect the double ended banana plug into the AL DTM and into the lock that is to be programmed observing proper tab direction 3 Press the Green Button on the AL DTM until the AL DTM displays the following 4 The AL DTM will display the following 5 Using the black keys change the CURRENT DOOR value until the door num...

Страница 17: ...k the AL DTM will perform the correct operation 1 Connect the AL DTM to the Lock Connect the double ended banana plug into the AL DTM and into the lock that is to be programmed observing proper tab direction 2 Press the Green Button on the AL DTM until the AL DTM displays the following The AL DTM displays the following 3 Present Function Card 2 to the lock The AL DTM will display the following Pac...

Страница 18: ... only other way to remove the card from the lock program is to erase all cards and lock programming described on page 11 Erase All Programming Erasing all programming then requires re programming the Function Cards and all new proximity cards Add new proximity cards as follows 1 With all proximity cards to be entered at hand present Function Card 3 to the lock The green LED will flash continuously...

Страница 19: ...ramming described on page 11 Erase All Program ming Erasing all programming then requires re programming the Function Cards and all new proximity cards Delete proximity cards as follows 1 With all proximity cards to be deleted at hand present Function Card 4 to the lock The green LED will flash continuously with beeping 2 Present the first proximity card you wish to delete When presented the beepi...

Страница 20: ...r as User Numbers 2003 2007 Toggles Passage Mode Door Is Unlocked When Function Card 5 is presented Passage Mode is enabled PL3000 remains unlocked indefinitely When Function Card 5 is re presented Passage Mode is disabled and the PL3000 re locks and resumes its normal operation Enter Passage Mode as follows Present Function Card 5 to the lock After unlocking the green LED blinks twice accompanied...

Страница 21: ...DL Windows or the AL DTM Print the Audit Log as follows 1 Turn on the printer 2 Place AL IR1 approximately 1 to 4 above the infrared LED as shown in image 3 Present Function Card 6 to the lock The lock will beep twice and flash a green LED 4 After a 2 second delay the PL3000 lock will send the infrared signals to the printer 5 If more than 20 log entries exist in the lock after the 20th entry a li...

Страница 22: ...ere pre sented the lock would henceforth remain in Passage Mode unlocked with none of the other cards able to remove the lock from this state Note Schedules created using DL Windows will still place the lock into or out of Passage Mode even when Function Card 7 is used Enter Total User Lockout mode as follows Present Function Card 7 to the lock The PL3000 unlocks and the green LED blinks twice acc...

Страница 23: ...on Card 9 access will be denied Later if you wish to grant the temporary worker re access sim ply re present Function Card 8 to the lock no need to have possession of Function Card 9 and Function Card 9 will be re enabled again for one time only NOTE Function Card 9 is enabled from the factory after the PL3000 is started for the first time When Func tion Card 9 is first presented after the PL3000 ...

Страница 24: ...orker presents Function Card 9 to the lock the PL3000 unlocks and allows access for one time only If the temporary worker re presents Function Card 9 access will be denied Later if you wish to grant the temporary worker re access sim ply re present Function Card 8 to the lock no need to have possession of Function Card 9 and Function Card 9 will be re enabled again for one time only NOTE Function ...

Страница 25: ...25 User Card Record Sheet NAME OF DOOR DEPARTMENT EMBOSSED NUMBER ON CARD USER NAME LAST FIRST DATE ACTIVATED COMMENTS Page ______ ...

Страница 26: ...ule Should the Group 1 enter the lock outside of the scheduled time the alarm will not disarm The alarm panel must be armed through other means The Burglary Alarm Panel must be programmed to disarm from an Armed State Only and the zone input must be programmed for input dis arming Programmed only through DL Windows GROUP 1 ENABLES GROUP 4 USERS A Group 1 USER CARD entry during a predefined schedul...

Страница 27: ...d reader will be disabled for the duration of Remote Input switch closure Features 26 27 28 will delay User Codes 12 and higher only except 297 298 and 299 Features 30 31 32 should be used with external DC power unless feature is used for a short duration and infrequently sustained closure of remote input or relay will drain batteries Sustained closure of remote input will inhibit scheduled events...

Страница 28: ...or au thorizes any other person purporting to act on its behalf to modify to change or to assume for it any other warranty or liability concerning its products In no event shall ALARM LOCK be liable for an amount in excess of ALARM LOCK s original selling price of the prod uct for any loss or damage whether direct indirect incidental consequential or otherwise arising out of any failure of the pro...

Отзывы: