5
Installation location
The Smart Water Valve must be installed:
• In a dry, indoor location.
• Downstream from the main shut-off valve on the
desired water supply line.
• With the control unit located above the valve.
Use drip loops wherever possible to avoid
damaging the electronics in the event of a leak.
• In compliance with all local plumbing and
electrical codes.
• Within 20 feet of a wall outlet.
• Easily visible and accessible to the end user.
Water shutoff valves and leak detection devices
should never be installed on a fire
suppression system.
4
5
Installation
Installing the Smart Water Valve
1. Shut off the water supply line and drain
the system.
2. Install the valve in the desired water supply
line using appropriate fittings. See “Installation
Location” for more information on choosing
a location.
3. After installing the valve, turn the water supply
on and ensure there are no leaks originating from
the valve or connections to the valve.
❹
Use a wrench or actuator to move the valve
stem so that it is parallel to the valve. Line up
the posts on the actuator with the holes on
the valve. Connect the actuator to the valve by
pressing on the actuator until it snaps into place.
5. Connect the actuator to the control unit using
the attached cable. The connector is keyed to
ensure proper alignment.
6. Mount the control unit to the wall using the
supplied wall bracket and anchors.
7. Connect the power supply to the locking
barrel connector on the control unit.
Turn counterclockwise to lock.
8. Plug the power supply
into the nearest
wall outlet. Verify power
by checking if the LEDs
are illuminated.
Testing the Smart Water Valve
1. Open a tap or faucet downstream of the Smart
Water Valve.
2. Press the close button and wait for the Smart
Water Valve closed light to turn solid. Check that
the valve has closed by verifying that no water is
flowing from the open fixture.
3. Press the open button and wait for the valve
open light to turn solid. Check that the valve has
opened by verifying that water is flowing from
the open fixture.
4. Close the open tap or faucet.
5. Add the Smart Water Valve to the
Z-Wave network.
Adding the Smart Water Valve to the
Z-Wave network
For best results, we recommend bringing the
Z-Wave controller into the area where the Smart
Water Valve is installed.
1. Put the Z-Wave controller into add mode.
Refer to controller guide for more information.
2. Press the networking
button on the side
of the Smart Water Valve control unit to begin
the add process. The network light on the control
unit will begin flashing.
3. After the Smart Water Valve is successfully
added, the network light on the Smart Water
Valve will turn solid. If the network light is not
illuminated after the add process, repeat
Steps 1 and 2.