Figure 2.Top View: PIR Lens Coverage  

 

As indicated in Figure 2, the camera coverage area is narrower than the PIR coverage 
area. When installing, mount sensor where subjects are likely to be centered in or across 
PIR and camera field of view.

 

INSTALLATION GUIDELINES 

 
Before permanently mounting the Image Sensor, evaluate potential locations and consider 
the following factors to ensure optimal performance and false alarm protection: 

Range

- Is the location close enough to the security panel to ensure adequate signal 

strength? 

False Alarm Immunity

- Is installation location false alarm prone? Reduce the risk of 

motion-triggered false alarms by making sure the location is free of vibration and the 
device does not face a local heat source, window, or areas with high pet activity. (Also, 
make sure area is free of elevated surfaces where pets may climb.)   

Capture Orientation

- Is the location ideally suited for detecting motion and capturing 

images when there is an intruder or activity? Consider where the subject is likely to enter 
the area and whether or not they will be facing the sensor. 

Lighting Conditions

- How good is the artificial and natural light? Will daytime and 

nighttime lighting conditions ensure adequate image quality?  
 

  If possible, locate sensor within 100 ft of the panel especially if there are many walls 

between the sensor & panel, or if the panel and sensor are located on different floors.  
While the transmitter may have an open air range of 400 ft, installation site conditions 
can reduce range considerably.  

 

  Avoid facing the sensor toward or close to areas that may affect communication such 

as metallic objects or electronics likely to produce interference. Verify sensor RF 

 

     communication at panel, even if within recommended distance.

 

 

  For optimal detection capabilities, mount the sensor where someone will most likely 

walk across the sensor coverage area as opposed to directly towards the sensor. 

 

  By default, the Image Sensor is set to “Normal” sensitivity. A more sensitive motion 

profile (“High”) and a less sensitive profile providing pet immunity for pets up to 40 lbs 
(“Low”) can be selected at the control panel or through the Alarm.com Dealer Website. 

 

  The Image Sensor is designed for indoor use only and should not be installed outdoors.  

For proper operation in pet immune applications, the room should be kept between 60° 
and 110° F. 

 

  To maximize night vision image quality, do not orient sensor towards surfaces that will 

create glare when infrared flash occurs. Avoid orienting the sensor such that the ceiling 
or adjacent walls are in the camera field of view. 

 

 

  The sensor must be mounted on a flat wall surface (do not set on shelf) free of 

 

     vibrations.   

 

A. PIR Sensitivity Settings 

By default, the Image Sensor is configured with a standard motion sensitivity profile  
(“Normal”). The sensor can also be set to a more sensitive motion profile (“High”) and a 
less sensitive profile with pet immunity for pets up to 40 lbs (“Low”). The sensitivity can be 
configured through the control panel or Alarm.com Dealer Website.   
  

(Note: Using the high sensitivity profile increases the risk of false alarms, especially if the 
sensor is facing windows or sources of heat. When mounting the sensor near windows or 
heat sources use caution and  select the “Low” PIR sensitivity setting.) 

B. PIR Activation and Test Mode 

During normal operation, the PIR can be activated at most once every three minutes while 
the system is disarmed. There is a 30-second delay after powering before PIR detection is 
active. For the first 3 minutes after a sensor is enrolled in a network, the sensor will enter 
PIR test mode and the sensor LED will illuminate for 3 seconds upon each motion 
activation (at most every 8 seconds). For additional testing time, put the sensor into test 
mode via the control panel or by tampering the sensor.   

D. Sensor LED 

By default, the image sensor LED does not illuminate when activated by motion unless the 
sensor is in test mode. The LED can be enabled via the Alarm.com Dealer Website for 
each Image Sensor on a customer’s account. When enabled, the LED illuminates for 3 
seconds upon motion activations (at most every 3 minutes while disarmed). 
 

SENSOR RESET BUTTON 

 

Insert a paperclip into the hole on the front of the sensor to access the reset button. Press 
and hold for 3 seconds to power cycle the sensor. Press and hold a full 10 seconds until 
the sensor LED flashes rapidly to reset the sensor and clear it from its network. The 
sensor must be reset prior to enrolling in a new network.  

(Note: The sensor can only be cleared from its network using the reset button if it is 
currently not communicating with its network. If the sensor is still communicating with its 
network, clear sensor by deleting it from the system it is enrolled in.) 

                        

 

                                 Figure 3.Sensor Reset Button 

BATTERY REPLACEMENT

 

When a sensor‘s batteries are low, the panel will display a low battery alert for the sensor 
(unless this trouble condition has been disabled for the panel display). Notifications are 
also issued via the Alarm.com platform if the customer has subscribed to this notification 
type.  

(Note: Low battery messages are only active at the panel between 7:00am and 10:00pm.) 
 

To replace the sensor batteries, slide the front of the sensor up off the sensor-back. (No 
need to remove or un-mount entire sensor-back and mounting arm.) To maximize battery 
life, replace the sensor batteries with 2 AA 1.5v Energizer Ultimate Lithium batteries. 
Dispose of used batteries according to the battery manufacturer instructions and following 
local regulations. 

 

Figure 4.  Removing Sensor for Battery Replacement 

 

(Note: The operation of the sensor with alkaline batteries has not been verified for  
compliance with UL standards.) 
 

TECHNICAL SPECIFICATIONS

 

 
Alarm.com Model Number

ADC-IS-200-LP 

 

Interlogix Part Numbers

 Image Sensor: 600-9400-IMAG 

Image Sensor Kit (Image Sensor w/ daughterboard): 600-9400-IMAG-KIT 
 

Power Source

:

 Optimal: 2 AA 1.5v Energizer Ultimate Lithium Batteries. Acceptable: 2 AA 

1.5v alkaline batteries (battery life may be reduced significantly). 
 

Expected Battery Life

:

 Approximately 2 years for lithium batteries. Battery life varies by 

use case depending on certain factors such as weak signal strength and frequency of 
motion activations, image captures, and IR flashes. 
 

Voltage Thresholds

:

 With lithium batteries, low battery alerts are issued at 3.05V. The 

sensor cannot operate when the voltage reads below 1.95V. 
 

Operating Temperature Range

:  

32° to 110°F for non-pet applications, 60° to 110°F for 

pet applications. Alkaline batteries are not suitable for temperatures below 50° F.

 

 
Weight

:

 3.1 oz. (with batteries, without mounting accessories) 

 

Dimensions

3.1’’ h x 1.8’’ w  x 2.3’’ d 

 
Supervisory Interval

100 minutes (sensor), 3 hours (alarm hardwire)

 

 

Wireless Signal Range

:

 Greater than 400 ft open air 

 

Color

:

 White

 

 

Recommended Mounting Height

8 ft  

 

Recommended Mounting Angle

:  

6° for large coverage area and rooms greater than 30 

ft (“teeth up” on mounting arm); 18° for rooms less than 30 ft (“teeth down” on mounting 
arm) 

 

Motion Profiles & Sensor Range

Normal (up to 30 ft, default), High (up to 35 ft), Low (up 

to 25 ft)  
 

 
 

 

40 ft 

20 ft 

20 ft 

0 ft 

40 ft 

50° 

90° 

 

Insert Paperclip to access reset button 

 

Hold Here 

Slide Up 

Отзывы: