Temperature

Battery life will be optimal between temperatures of 32°F to 140°F (0°C to
60°C), though the device can operate from -40°F to 140°F (-40°C to 60°C).

Reed Switches

3 unique reed switch locations to choose from that can be activated with
included magnet.

Loop Input

• The Alarm.com Flex IO™ sensor can be powered by battery or external

power.

• Dry Contact, Normally Open (NO), or Normally Closed (NC).

• Optional EOL resistor can be 300 kΩ or higher.

Relay Output

• If used, the Alarm.com Flex IO™ sensor must be externally powered (not

compatible with battery power).

• Up to 24 V (AC or DC), 40 mA max current.

• Can be used only for control lines/dry contact.

Caution

: Can never be connected directly to control electrical loads. This will

damage the device.

Dimensions

• Main unit: 6.8 x 2.2 x 1.3" (17.3 x 5.6 x 3.3 cm).

• Magnet: 3.1 x 0.68 x 0.87" (7.9 x 1.7 x 2.2 cm).

Power

• Works with DC-wired power or battery power (battery backup

recommended for wired installations).

• 6 to 15 VDC supply. Minimum 1 A.

Battery Power

• Four 1.5 V AA lithium batteries (iron disulfide).

• 2+ years of battery life, depending on battery chemistry and operating

temperature.

Regulatory Information

Important

: The Alarm.com Flex IO™ sensor is a monitoring device that is not intended for life safety use cases.

FCC

https://answers.alarm.com/Partner/Installation_and_Troubleshooting/Cellular_Sensors/Alarm.com_Flex_IO%E2%84%A2_sen…

Updated: Mon, 10 Oct 2022 23:21:36 GMT

13

Содержание ADC-FLEX-100

Страница 1: ...ing compatible devices that lack long range connectivity Important The Alarm com Flex IO sensor is a monitoring device that is not intended for life safety use cases For a video guide about installing...

Страница 2: ...moved from its location Alarm com Flex IO sensor Pull Apart Installation Guide Gate control using a compatible gate controller Selecting Gate Control Contact Sensor or Gate Control Wired Contact allow...

Страница 3: ...put tools and supplies if required not included 18 22 AWG wire Power supply ADC FLEX 100 PS Wire retention clip ADC FLEX 100 WRC Step 1 Determine location Before installing your device it is important...

Страница 4: ...re available Only one reed switch position can be active at a time You will select the reed switch position in Step 2 Use the tick marks on the sides of the device for guidance Position 1 Position 2 P...

Страница 5: ...ed flush to the install surface Important A mounting tamper is located on the back of the Alarm com Flex IO sensor This tamper button must be fully pressed until you hear a clicking sound to avoid rep...

Страница 6: ...ions Anything from 6 15VDC is acceptable A minimum of 1 Amperage is required For best performance 18 22 AWG wire should be used Important DC power is required for relay installations due to increased...

Страница 7: ...de is initiated the LED will display the cell signal strength in a continuous loop for 2 minutes based on the patterns below It may take up to 30 seconds for the signal strength to be acquired As you...

Страница 8: ...ast one Alarm com Flex IO sensor has been added to their Service Package The Alarm com Flex IO sensor is listed under Cellular Sensors 4 Click Equipment 5 Click Cellular Sensors 6 Click Add a Cellular...

Страница 9: ...any devices into the screw terminals it is recommended to do so before mounting the Alarm com Flex IO sensor https answers alarm com Partner Installation_and_Troubleshooting Cellular_Sensors Alarm co...

Страница 10: ...to over torque the screws Power tools should be avoided If pilot holes are necessary a drill bit size of 5 64 is recommended Using zip ties Zip ties should have a maximum width of 0 34 inches UV resi...

Страница 11: ...e the battery door screw is securely tightened until the door tamper is no longer detected and then add an additional turn to the screw This will also ensure a waterproof seal If this screw is not ful...

Страница 12: ...d blinking twice when the device is tripped If the device is not communicating with Alarm com see Advanced Troubleshooting Using MobileTech For more information on LED patterns see Alarm com Flex IO s...

Страница 13: ...d only for control lines dry contact Caution Can never be connected directly to control electrical loads This will damage the device Dimensions Main unit 6 8 x 2 2 x 1 3 17 3 x 5 6 x 3 3 cm Magnet 3 1...

Страница 14: ...or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Co...

Отзывы: