A chimney inside the house must have at least 2” (50mm) of clearance to the combustible structure.  A chimney

outside the house must have at least 1” (25mm) clearance to the combustible structure.  Firestops must be

installed in the spaces where the chimney passes through floors and/or ceiling (Figure 5).

The chimney must have a fire clay flue liner (or equivalent) with a minimum thickness of 5/8” (16mm) and

must be installed with refractory mortar.  There must be at least ½” (13mm) air space between the flue liner and

the chimney wall (Figure 4).  An equivalent liner must be a listed chimney liner system or other approved

material.

FIGURE 4

FIGURE 5

Page 21

1. Remove door from stove and lay on a padded flat surface.

2. Remove glass frame and screws with a Phillips screwdriver (turn screws counterclockwise).

3. Lift glass frame pieces and glass out of the door frame.

4. Lay new glass with fiberglass tape around it into the door frame, making sure the Quadra-Fire logo reads

correctly to the outside.

5. Place glass frame pieces over the fiberglass tape on the edges of the glass.  Be sure glass is centered in the

opening (i.e., same space top and bottom, left and right sides).

6. Reinstall screws tight enough to hold glass and frame in place.  DO NOT OVERTIGHTEN.

7. Check again for centering of glass in door frame, and give all screws a final tightening.

DOOR HANDLE ASSEMBLY

GLASS REPLACEMENT

LATCH CAM

NOTE:

Spring handle not included in door

handle assembly.  When replacing

door handle, either use old spring

handle or order new spring handle

separately.

DOOR CROSS SECTION

FIBERGLASS

 TAPE

GLASS

GLASS FRAME

GLASS TAB SCREW

DOOR GASKET ROPE

REPLACE ONLY

WITH CERAMIC

GLASS

Содержание Quadra Fire 1900

Страница 1: ...may have other rights which may vary from state to state This limited Lifetime Warranty covers items such as but not limited to combustion chambers doors gold plating steel baffles manifold tubes and...

Страница 2: ...n 14 Outside air kit installation 15 Pedestal and leg installation 16 Operating instructions Burning process 17 Combustion air system 17 Fan operating instructions 18 Operating tips 18 Burning guideli...

Страница 3: ...21 Black door 832 1891 Trim door 832 0711 Gold door Leg mounting bracket for mobile home installations SERVICE PARTS 832 2530 Kaowool blanket 4 piece 832 2470 Firebox brick set 832 0550 Individual bri...

Страница 4: ...26 3 4 680mm 13 3 8 340mm 2 51mm Page 25 1 Unscrew and remove the rear heat deflector 2 Attach the two S clips to the upper edge of the outer wall of the stove 3 Set top heat shield on stove and push...

Страница 5: ...s indicated NOTE A 3 8 10mm minimum thickness tile or equivalent is recommended but not required NFPA 211 Use a noncombustible material with 1 25mm ventilated air space to reduce clearances However th...

Страница 6: ...ed away from the heating appliance and close to the sleeping areas Follow the smoke detector manufacturer s placement and installation instructions and be sure to maintain regularly 2 A conveniently l...

Страница 7: ...oof line surrounding trees prevailing winds and nearby hills can influence stove performance CONNECTION TO A MASONRY CHIMNEY 1 CHIMNEY Should the stove be connected to a masonry chimney the chimney sh...

Страница 8: ...me and screws with a Phillips screwdriver turn screws counterclockwise 3 Lift glass frame pieces and glass out of the door frame 4 Lay new glass with fiberglass tape around it into the door frame maki...

Страница 9: ...ainst the glass Clean glass with a nonabrasive glass cleaner such as Windex Abrasive cleaners may scratch and cause glass to crack Inspect glass regularly If you find a crack or break immediately put...

Страница 10: ...ches or other combustibles are in the immediate area of the stove Be sure the room is adequately ventilated and the flue unobstructed 5 Light the paper in the stove NEVER light or rekindle stove with...

Страница 11: ...r may be left on throughout the burn 3 Medium burn setting The blower should be left off until a good burn is established then turned on at a medium or high rate 4 Low burn setting The blower tends to...

Страница 12: ...Fire requires three things to burn fuel air and heat So if heat is robbed from the stove during the drying stage the new load of wood has reduced the chances for a good clean burn For this reason it i...

Страница 13: ...tructure that is within 10 3048mm of the chimney measured horizontally Figure 5 REMEMBER Follow the manufacturer s installation instructions and maintain the manufacturer s specified clearance distanc...

Страница 14: ...ith two 20 screws supplied 2 Mount rear cover plate with four mounting screws supplied This cover will seal the pedestal floor installation or have a 4 101mm hole rear installation 3 Both kits have tw...

Отзывы: