Note the positions on the multi-port valve
•
Main drain valve open
•
Skimmer/Balance tank valve closed
•
Vacuum valve closed
•
Switch off pump
•
Open waste line valve
•
Turn multi-port valve to
BACKWASH
•
Switch on pump
•
Watch dirt in sight glass
•
Turn off pump after 3 mins
•
Turn multi-port valve to
RINSE
•
Switch on pump for 1 min
•
Switch off pump
•
Turn multi-port valve to
FILTER
•
Close the waste line valve
•
Switch on pump
•
Open skimmer/Balance tank valve as
required.
•
ALWAYS SWITCH OFF THE PUMP
BEFORE OPERATING THE MULTI-PORT
VALVE
Recommended Procedure for
Backwashing the Filter