Akytec ITP14 Скачать руководство пользователя страница 9

 

 

akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany   Tel.: +49 (0) 511 16 59 672-0 · 

www.akytec.de

 

Name 

Display

 

Parameter 

Valid value 

Description 

Default 

d.Fn

С

 

d.FnС

 

Alarm function 

ON 

OFF 

OFF 

Table 7.3   Service menu

 

Display

 

Comments

 

Valid values

 

гES

 

Restore factory settings 

User settings 

Factory settings 

CLbг 

Service function 

SoFt

 

Firmware version

 

 

Fig. 7.1   Device menu

 

Note: 

1.  The minus sign is displayed in the most significant digit, together with 1. The display 

range is -199.9...999.9 if 

di.P

 = 

---.-

Содержание ITP14

Страница 1: ...ahrenwalder Str 269 A 30179 Hannover Germany Tel 49 0 511 16 59 672 0 www akytec de ITP14 Universal process indicator User guide ITP14_2018 03_0272_EN All rights reserved Subject to technical changes...

Страница 2: ...ations 2 2 1 Environmental conditions 2 3 Intended use 3 4 Functions 3 5 Installation 3 5 1 Wiring 3 5 1 1 Input 4 5 1 2 Output 4 6 Operation 5 6 1 Control 5 6 2 Alarm 6 6 3 Filter 6 6 4 Square root f...

Страница 3: ...put resistance 0 5 mA 0 4 20 mA 120 ohm 0 2 10 V 250 kohm Output 1 Type NPN transistor Loading capacity 200 mA 42 V DC Enclosure for panel mounting Dimensions 48 x 26 x 65 mm Weight approx 30 g Table...

Страница 4: ...mode see 7 The function buttons are positioned on the rear part of the device Main functions Analog input 0 5 mA 0 4 20 mA 0 2 10 V Measuring and displaying of a process value Signal scaling Adjustabl...

Страница 5: ...rovided with its own power supply line and electric fuse I 0 5 A The maximum conductor cross section is 1 mm Wires should be stripped for approx 8 10 mm 5 1 1 Input Fig 5 2 Current sensor wiring Fig 5...

Страница 6: ...yed The scale factor is calculated based on the parameter di Lo Lower measuring limit and di Hi Upper measuring limit The display decimal point can be specified in the parameters di P For other signal...

Страница 7: ...ut signal and the lower the susceptibility to interference is The filter is deactivated if td 0 Fig 6 2 Filter time constant 6 4 Square root function The function is intended for transmitters with the...

Страница 8: ...tion while changing parameter if no button was pressed within 20 s the device returns to the operating mode automatically Table 7 2 Programming parameters Name Display Parameter Valid value Descriptio...

Страница 9: ...Default d Fn d Fn Alarm function ON OFF OFF Table 7 3 Service menu Display Comments Valid values ES Restore factory settings 0 User settings 1 Factory settings CLb Service function SoFt Firmware vers...

Страница 10: ...mage The device should be cleaned with a damp cloth only No abrasives or solvent containing cleaners may be used 9 Transportation and storage Pack the device in such a way as to protect it reliably ag...

Отзывы: