3  Intended use 

The device may only be used in the manner described in this user guide, properly installed 
and in accordance with the specification. Damages caused by disregarding the instructions 
of this manual are without liability. Non-observance of the safety guidelines may result in 
damage to the device and injury to personal. 

Improper use 

Any other use is considered improper. Especially to note: 

 

The ITP14 may not be used for medical devices that sustain, monitor or otherwise affect 
human life or health. 

 

The device may not be used if the environmental conditions (temperature, humidity etc.) 
are not within the limits indicated in the specification.

 

 

The device may not be used in potentially explosive environment or in an atmosphere 
with chemically active substances.

 

4  Functions 

A 4-digit LED display with 14 mm character height is located on the front of the device to 
display the process value or error messages in operation (see 6) and programming 
parameters in programming mode (see 7). The function buttons are positioned on the rear 
part of the device. 

Main functions: 

 

Analog input 0-5 mA, 0(4)-20 mA, 0(2)-10 V 

 

Measuring and displaying of a process value 

 

Signal scaling 

 

Adjustable decimal point position 

 

Display range -999…9999

 

 

ON/OFF control with NPN output

 

 

Square root function (for special transmitters) 

 

Digital filter 

 

Alarm function 

 

Error indication when the input signal is out of range 

 

Error indication when wire break or short circuit

 

5  Installation 

 CAUTION 

Improper installation can cause serious or minor injuries and damage the device. 
Installation must be performed only by fully qualified personnel.
 

The device is designed for panel mounting in a borehole of Ø22.5 mm (see Appendix A for 
dimensional drawings).

 

Carefully position the supplied gasket on the display rear surface. Insert the cylindrical body 
of the device into the borehole and tighten the nut from the rear side of the panel.

 

5.1 

Wiring

 

 CAUTION 

Switch on the power supply only after the wiring of the device has been completely 
performed
 

 

 

NOTICE 

Switch off the device before checking the sensor and connection lines. 
For circuit integrity check use only the measuring device with the output voltage max. 
4.5 V to prevent the device damage. Disconnect the sensor in case of higher voltage.
 

 

 

 

Содержание ITP14

Страница 1: ...ahrenwalder Str 269 A 30179 Hannover Germany Tel 49 0 511 16 59 672 0 www akytec de ITP14 Universal process indicator User guide ITP14_2018 03_0272_EN All rights reserved Subject to technical changes...

Страница 2: ...ations 2 2 1 Environmental conditions 2 3 Intended use 3 4 Functions 3 5 Installation 3 5 1 Wiring 3 5 1 1 Input 4 5 1 2 Output 4 6 Operation 5 6 1 Control 5 6 2 Alarm 6 6 3 Filter 6 6 4 Square root f...

Страница 3: ...put resistance 0 5 mA 0 4 20 mA 120 ohm 0 2 10 V 250 kohm Output 1 Type NPN transistor Loading capacity 200 mA 42 V DC Enclosure for panel mounting Dimensions 48 x 26 x 65 mm Weight approx 30 g Table...

Страница 4: ...mode see 7 The function buttons are positioned on the rear part of the device Main functions Analog input 0 5 mA 0 4 20 mA 0 2 10 V Measuring and displaying of a process value Signal scaling Adjustabl...

Страница 5: ...rovided with its own power supply line and electric fuse I 0 5 A The maximum conductor cross section is 1 mm Wires should be stripped for approx 8 10 mm 5 1 1 Input Fig 5 2 Current sensor wiring Fig 5...

Страница 6: ...yed The scale factor is calculated based on the parameter di Lo Lower measuring limit and di Hi Upper measuring limit The display decimal point can be specified in the parameters di P For other signal...

Страница 7: ...ut signal and the lower the susceptibility to interference is The filter is deactivated if td 0 Fig 6 2 Filter time constant 6 4 Square root function The function is intended for transmitters with the...

Страница 8: ...tion while changing parameter if no button was pressed within 20 s the device returns to the operating mode automatically Table 7 2 Programming parameters Name Display Parameter Valid value Descriptio...

Страница 9: ...Default d Fn d Fn Alarm function ON OFF OFF Table 7 3 Service menu Display Comments Valid values ES Restore factory settings 0 User settings 1 Factory settings CLb Service function SoFt Firmware vers...

Страница 10: ...mage The device should be cleaned with a damp cloth only No abrasives or solvent containing cleaners may be used 9 Transportation and storage Pack the device in such a way as to protect it reliably ag...

Отзывы: