14. Logs

14.1.Access Log

If you want to search and check on door access history, you can search and

check the door logs on the device web

Status > Access Log

interface.

Содержание A01

Страница 1: ...Version 1 0 Date Jan 2021 ...

Страница 2: ...istrators who need to properly configure the access control terminal This manual applies to 101 30 0 70 version and it provides all the configurations for the functions and features of A01 access control terminals Please visit Akuvox forum or consult technical support for any new information or the latest firmware ...

Страница 3: ...in order to prevent the persons from injury Caution Always abide by this information in order to prevent the damages to the device Note Informative information and advice from the efficient use of the device Tip Useful information for the quick and efficient use of the device ...

Страница 4: ...Related Documentation You are advised to refer to the related documents for more technical information via the link below http wiki akuvox com ...

Страница 5: ...ess Schedule 13 11 1 1 Create Door Access Schedule 13 11 1 2 Import and Export Door Access Schedule 15 12 Door Unlock Configuration 16 12 1 Configure RF Card for Door Unlock 16 12 1 1 Configure RF Card on the Web Interface 16 12 1 1 1 Configure RF Card Code Format 17 12 1 2 Unlock by NFC 17 12 1 3 Unlock by HTTP Command on Web Browser 18 12 1 4 Unlock by Exit Button by the Door 19 12 1 5 Unlock by...

Страница 6: ...ovisioning Configuration 33 18 5 Static Provisioning Configuration 35 19 Integration with Third Party Device 37 19 1 Integration via Wiegand 37 19 2 Integration via HTTP API 38 20 Password Modification 39 20 1 Modify the Password 39 20 2 Web Interface Automatic Log out 39 21 System Reboot and Reset 40 21 1 Reboot 40 21 2 Reset 41 22 Abbreviations 42 23 FAQ 44 24 Contact Us 45 ...

Страница 7: ... standalone device thus saving your solution costs Equipped with a card reader 125kHz and 13 5MHz which is capable of handling a majority of cards in wide use currently A01 is designed to provide you with greater flexibility and security than those traditional access control systems A01 access control terminal applies to residential buildings office buildings and their complex ...

Страница 8: ...A01 Access Control Admin Guide AKUVOX SMART INTERCOM www akuvox com 2 2 Change Log The change log will be updated here along with the changes in new software version ...

Страница 9: ... Front panel Toughened Glass Frame Aluminum Alloy Front panel Touch Keypad Frame Aluminum Alloy Relay Out 1 1 Input 2 2 Wiegand PoE RAM 128M 128M ROM 128M 128M Card Reader 13 56MHz 125KHz 13 56MHz 125KHz Wi Fi X X Bluetooth X X IP Rating IP65 IP65 LTE X X USB X X External SD Card X X Wall Mounting Flush Mounting Desk Mounting X X ...

Страница 10: ...tem this section covers network and time setting firmware upgrade device reset reboot configuration file auto provisioning system log and PCAP password modification as well as device backup Tool selection Akuvox has many configuration tools for you to set up devices more conveniently Here we list some common tools please contact your administrator to get the tool if you need them 1 ACMS ACMS Acces...

Страница 11: ...alled correctly and connect a normal network Using Akuvox IP scanner tool to search the device IP address in the same LAN Then use the IP address to login in the web browser by user name and password admin and admin Tip Please refer to the URL below for the IP scanner application instructions http wiki akuvox com doku php id tool ip_scanner s ip s scanner ...

Страница 12: ...zone is selected the device will automatically notify the NTP server of its time zone so that the NTP server can synchronize the time zone setting in your device To configure the configuration on the device web System Time interface Parameter Set up Time Zone select the specific time zone depending on where the device is used and then press Confirm tab for the confirmation The default time zone is...

Страница 13: ...e Parameter Set up Backlight Intensity adjust the backlight intensity the bigger value the brighter backlight Backlight Enabled tick the check box if want to enable the card reader LED lighting and vice versa Start Time End Time H enter the time span for the LED lighting to be valid e g if the time span is from 18 22 it means LED light will stay on during the time span from 6 00 pm to 10 00 pm in ...

Страница 14: ...ce 8 1 1 Volume Configuration You can configure the Mic volume according to your need for open door notification Moreover you can also set up the tamper alarm volume when unwanted removal of the access control terminal occurs To configure the configuration on web Hardware Audio Volume Control interface Parameter Set up Tamper Alarm Volume set the tamper alarm volume from 0 15 according to your nee...

Страница 15: ...nfiguration on web System Network LAN Port interface Parameter Set up DHCP select the DHCP mode by checking off the DHCP box DHCP mode is the default network connection If the DHCP mode is selected then the access control terminal will be assigned by the DHCP server with IP address subnet mask default gateway and DNS server address automatically Static IP select the static IP mode by checking off ...

Страница 16: ... and the access control terminal connects to DNS2 server when the primary DNS server is unavailable 10 Relay Setting You can configure the relay switch es for the door access on the web interface 10 1 1 Relay switch setting To configure the configuration on web Hardware Relay Relay interface Parameter Set up Trigger Delay Sec set the relay trigger delay timing Ranging from 1 10 Sec For example if ...

Страница 17: ...devices connected to the relay switch needs to be powered by power adapters as relay switch does not supply power 10 2 Web Relay Setting In additional to the relay that is connected to the access control terminal you can also control the door access using the network based web relay on the device and on the device web interface 10 2 1 Configure Web Relay on the Web Interface Web relay needs to set...

Страница 18: ...rer Password enter the password provided by the web relay manufacturer The password is authenticated via HTTP and you can define the passwords using http get in Action Web Relay Action enter the specific web relay action command provided by the web manufacturer for different actions by the web relay http admin admin 192 168 1 2 state xml relayState 2 After the web relay is set up you can configure...

Страница 19: ... conveniently applied to the door access control intended for individual user or a group of users created Moreover you can edit your door access schedule if needed 11 1 1 Create Door Access Schedule You can create the door access schedule on the daily or weekly basis and you can also create schedule that allows you to plan for a longer period of time in addition to running the door access schedule...

Страница 20: ...ART INTERCOM www akuvox com 14 Click Add to create a daily schedule select Schedule Mode as Daily Click Add to create a weekly schedule select Schedule Mode as Weekly Click Add to create a longer period schedule select Schedule Mode as Normal ...

Страница 21: ...rt and Export Door Access Schedule In addition to creating door access schedule separately you can also conveniently import or export the schedules in order to maximize your door access schedule management efficiency To configure the configuration on web Directory Schedule interface ...

Страница 22: ...e schedule 12 Door Unlock Configuration A01 access control terminal offer you three types of door access via RF card You can configure them on web interface Moreover you can import or exporting the user configured files including access control information 12 1 Configure RF Card for Door Unlock 12 1 1 Configure RF Card on the Web Interface ...

Страница 23: ...ess you can change the RF card code format to be identical with that applied in the third party system To configure the configuration on web Hardware Card Reader interface Parameter Set up IC ID Card Display Mode select the card format for the ID Card for the door access among five format options 8H10D 6H3D5D W26 6H8D 8HN 8HR The card code format is 8HN by default in the access control terminal 12...

Страница 24: ...roaching the device physically for the door access by typing in the created the HTTP command URL on the web browser to trigger the relay when you are not available by the door for the door access To configure the configuration on web Hardware Relay Open Relay Via HTTP interface Parameter Set up Enable enable the HTTP command unlock function by clicking on Enable field User Name enter the user name...

Страница 25: ...you can configure the access control terminal Input to trigger the relay for the door access To configure the configuration on web Hardware Input interface Parameter Set up Trigger Electrical Level select the trigger electrical level options between High and Low according to the actual operation on the exit button Action to execute set actions to be triggered by the input Email and HTTP URL action...

Страница 26: ...door via pin code You can set up PIN code on the Directory User click Add then input the private code Parameter Set up Code input the private code The code should contain 2 8 digits After the configuration PIN will be displayed on the user interface 12 1 6 Unlock by Public Code A02 supports public pin code for administrators or cleaners to open the door You can set up public pin code on Hardware R...

Страница 27: ...ation A02 supports dual access authentication mode You can set up the dual access authentication mode on Hardware Relay Access Authentication Mode interface Parameter Set up Authentication Mode Any Method indicates RF card or PIN code RF Card PIN means swiping the card first then input the PIN code PIN RF Card means input the PIN code then swipe the card 12 2 2 Dual Authentication Interval You can...

Страница 28: ...rval time as 5 seconds then the interval between the two access authentication must be limited within 5 seconds 13 Security 13 1 Tamper Alarm Setting Tamper alarm function serves as a protection against any unauthorized removal of the devices by triggering off the temper alarm on the device To configure the configuration on web System Security Tamper Alarm interface Parameter Set up ...

Страница 29: ...us is shifted from Low to High status Note Disarm tab will turn gray when the temper alarm is cleared The round rubber button at the back of the device must be in press down status otherwise the alarm will not be fired 13 2 Security Notification Setting 13 2 1 Email Notification Setting If you want to receive the security notification via email you can configure the Email notification on the web i...

Страница 30: ... email address Receiver s Email Name enter the name of the email receiver SMTP server address enter the SMTP server address of the sender Port enter the port number from which the email is sent out SMTP user name enter the SMTP user name which is usually the same with sender s email address SMTP password configure the password of SMTP service which is same with sender s email address Email subject...

Страница 31: ...ol Admin Guide AKUVOX SMART INTERCOM www akuvox com 25 14 Logs 14 1 Access Log If you want to search and check on door access history you can search and check the door logs on the device web Status Access Log interface ...

Страница 32: ...cesses Time select the specific time span of the door logs you want to search check or export Name Code select the Name and Code options to search door log by the name or by the PIN code Type display the access type like card or HTTP 15 Debug 15 1 System Log for Debugging System log in the access control terminal can be used for debugging purpose If you want to export the system out to a local PC ...

Страница 33: ...xport tab to export temporary debug log file to a local PC Remote System Log Enabled select Enable or Disable if you want to enable or disable the remote system log Remote System Server enter the remote server address to receive the device log And the remote server address will be provided by Akuvox technical support 15 2 PCAP for Debugging PCAP in A01 access control terminal is used to capture th...

Страница 34: ...rt the data packets to your Local PC PCAP Auto Refresh Enabled select Enable or Disable to turn on or turn off the PCAP auto fresh function If you set it as Enable then the PCAP will continue to capture data packet even after the data packets reached its 50M maximum in capacity If you set it as Disable the PCAP will stop data packet capturing when the data packet captured reached the maximum captu...

Страница 35: ...RT INTERCOM www akuvox com 29 17 Backup Configuration files can be imported to or exported out of the device to your local PC on the device web System Maintenance Others interface if needed Note Firmware files should be rom format for upgrade ...

Страница 36: ...tions and upgrading on A01 access control terminal can be done on the web interface via one time auto provisioning and scheduled auto provisioning via configuration files thus saving you from setting up configuration needed one by one manually on the access control terminal 18 1 Provisioning Principle ...

Страница 37: ... the access control terminal 18 2 Configuration Files for Auto provisioning Configuration files have two formats for the auto provisioning one is the general configuration files used for the general provisioning and other one is the MAC based configuration provisioning The difference between the two types of configuration files is shown as below General configuration provisioning a general file is...

Страница 38: ...d configuration files 18 3 AutoP Schedule Akuvox provides you with different Autop methods that enable the access control terminal to perform provisioning for itself in a specific time according to your schedule To configure the configuration on web System Auto Provisioning Automatic Autop interface Parameter Set up Power On select Power on if you want the device to perform Autop every time it boo...

Страница 39: ...ained using DHCP option which allows device to send a request to a DHCP server for a specific DHCP option code If you want to use Custom Option as defined by users with option code range from 128 255 you are required to configure DHCP Custom Option on the web interface To set up DHCP AutoP with Custom Option and Power on mode And export Autop Template to edit the configuration Then set up DHCP Opt...

Страница 40: ...cify this To make it work you need to configure the DHCP server for the option 66 with the update server URL in it DHCP Option 43 If the device does not get an URL from DHCP Option 66 it will automatically use DHCP Option 43 This is done within the software and the user does not need to specify this To make it work you need to configure the DHCP server for the option 43 with the update server URL ...

Страница 41: ...PS are the protocols that can be used for upgrading the device firmware and configuration To download the Autop template first and setup Autop server on System Auto Provisioning Manual Autop interface Parameter set up URL set up tftp http https ftp server address for the provisioning User Name set up a user name if the server needs an user name to be accessed to otherwise leave it blank Password s...

Страница 42: ...s encrypted with AES otherwise leave the field blank Note Server Address format TFTP tftp 192 168 0 19 FTP ftp 192 168 0 19 allows anonymous login ftp username password 192 168 0 19 requires a user name and password HTTP http 192 168 0 19 use the default port 80 http 192 168 0 19 8080 use other ports such as 8080 HTTPS https 192 168 0 19 use the default port 443 Tip Akuvox do not provide user spec...

Страница 43: ... Set up Wiegand Display Mode select Wigand Card code format among 8H10D 6H3D5D 6H8D 8HN 8HR RAW Wiegand Card Reader Mode set the Wiegand data transmission format among three options Wiegand 26 Wiegand 34 Wiegand 58 The transmission format should be identical between the access control terminal and the device to be integrated Wiegand Transfer Mode set the transfer mode between Input or Output if th...

Страница 44: ...tted correctly according to the established data transmission format 19 2 Integration via HTTP API HTTP API is designed to achieve an network based integration between the third party device with the Akuvox intercom device You can configure the HTTP API function on the web Services HTTP API interface for the integration Parameter set up HTTP API select Enable or Disable to enable or disable the HP...

Страница 45: ... select for the integration 20 Password Modification 20 1 Modify the Password On the device web interface you can set and change password for accessing the web System Security Web Password Modify interface In addition you can also select the user role when setting passwords 20 2 Web Interface Automatic Log out You can set up the web interface automatic log out timing requiring re login by entering...

Страница 46: ...eed to login the website again 21 System Reboot and Reset 21 1 Reboot If you want to restart the device you can operate it on the device web System Upgrade Basic interface as well Moreover you can set up schedule for the device to be restarted To set up the device restart schedule on web System Auto Provisioning Reboot Schedule interface ...

Страница 47: ...de AKUVOX SMART INTERCOM www akuvox com 41 21 2 Reset If you want to reset the device system to the factory setting you can it on the web System Upgrade interface You can also hold the reset button 12s on the back of A01 to reset ...

Страница 48: ...y Lamp Field COM Common CPE Customer Premise Equipment CWMP CPE WAN Management Protocol DTMF Dual Tone Multi Frequency DHCP Dynamic Host Configuration Protocol DNS Domain Name System DND Do Not Disturb DNS SRV Service record in the Domain Name System FTP File Transfer Protocol GND Ground HTTP Hypertext Transfer Protocol HTTPS Hypertext Transfer Protocol Secure Socket Layer IP Internet Protocol ID ...

Страница 49: ...al Opened NC Normal Connected NTP Network Time Protocol NAT Network Address Translation NVR Network Video Recorder ONVIF Open Network Video Interface Forum SIP Session Initiation Protocol SNMP Simple Network Management Protocol STUN Session Traversal Utilities for NAT SNMP Simple Mail Transfer Protocol SDMC SIP Devices Management Center TR069 Technical Report069 TCP Transmission Control Protocol T...

Страница 50: ...he same LAN network Q2 What is the supported temperature range for A01 A2 Working Temperature 20 C 55 C Storage Temperature 30 C 70 C Q3 Do Akuvox devices support Modbus protocol A3 No Q4 Do access control terminals support these card types Prox Legacy iClass iClassSE HID Mifare HID DESFire and HID SEOS A4 Sorry they are not supported They need to be implemented via hardware modifications ...

Страница 51: ...ontact Us For more information about the product please visit us at www akuvox com or feel free to contact us by Sales email sales akuvox com Technical support email support akuvox com Telephone 86 592 2133061 ext 7694 8162 We highly appreciate your feedback about our products ...