8.) Filter change / filter change indicator 
 

The unit is equipped with a filter change indicator. Depending on the duration of use and the degree of soiling, this 
may be signalled to you by the indicator panel flashing ! This is the time when the pre-filter should be cleaned 
and/or the fine filters replaced. 
 
Notes: 
 

  Under normal conditions, the fine filters last for approx. 4,300 operating hours or up to 18 months with an 

operation of approx. 8 hours per day ! In more polluted rooms, e.g. smokers' households, the filters may have 
to be replaced after approx. 6 months (at the latest when the HEPA filter is dark brown, it should be replaced) ! 

  Disconnect the mains plug before cleaning/replacing the filters. For best filtration results, we strongly 

recommend that you use only original filters from the manufacturer. 

  Never wash the fine filters. (Only the pre-filter and the ESP filter can be cleaned). 

 
To change the filter, follow the instructions and diagrams as described earlier in the operating instructions under 
point 3.). 
 
After the pre-filter has been cleaned and/or the fine filters have been replaced, it is necessary to reset the filter 

change indicator. To do this, switch the air purifier on again and now press the On/Off button 

permanentlyfor 

approx. 3 seconds! The successful reset is signalled by a short acknowledgement tone. In addition, the flashing of 
the display field will stop again. 
 
Cleaning the ESP filter block: 
 
The ESP filter block made of stainless steel can be cleaned as follows. 

 

  Carefully pull the ESP filter block out of the drawer like a honeycomb (touch 

the top and bottom). 

  First remove the coarse dust and dirt with a hoover. 

  Then brush the fins of the ESP filter block with a soft brush. 

  Again, remove any loose dust and dirt with a hoover. Also remove any dust 

residue from the drawer itself. 

  Now rinse the ESP filter block in a sink with the help of washing-up liquid and 

a soft brush (see illustration opposite). 

  Allow the ESP filter block to dry completely. 

  Finally, push the ESP filter block back into its drawer and close the filter 

compartment door properly. 

 

 
9.)  Cleaning & Storage 
 

Please always disconnect the mains plug first and allow the air purifier to drain completely before carrying out any 
cleaning activities on your unit ! 
 
9.1 Cleaning: 
 

  Use a soft and damp cloth to clean the outside of the unit. 

  Only use mild cleaning agents to clean your air purifier. 

  Please ensure that water does not get into the interior of the unit or the electrical display panel (display) at any 

time ! 

 
9.2 Storage: 
 

  We recommend covering the unit for storage or ideally packing it in its original box. 

  Store the unit in a dry and sufficiently ventilated place/space. 

 
 
 
 
 

Содержание WDH-H3

Страница 1: ...uct To ensure that you get a lot of enjoyment from this product here are a few more tips In case of any problems We hope that the unit meets your expectations If despite the greatest possible care the...

Страница 2: ...and solvents Anion exchanger Produces approx 6 8 million anions ions per second which pro actively combat smoke and other dirt particles in the room Air sensor operation automatic mode Automatically m...

Страница 3: ...d wetness Only use the recommended voltage for operating the unit Make sure that the power cable is unfolded untied before connecting it to the socket Make sure that the plug is cleanly and properly c...

Страница 4: ...ing handle Exhaust air Control and display panel Power cable connection Filter compartment door Air intake Control and display panel Exhaust air Filter compartment door Carrying handle Air intake Pre...

Страница 5: ...unit operates at low fan strength Cloud is neutral air quality is polluted unit operates at medium fan speed Cloud is sad air quality is poor unit operates at high fan speed Electrostatic filter block...

Страница 6: ...ilter HEPA activated charcoal filter we recommend that the white HEPA side faces to the right so that the air flows through the HEPA filter first and only then through the activated charcoal filter Fi...

Страница 7: ...HEPA filter combined with the active carbon filter 4 Active carbon filter combined with the HEPA filter 4 The right location Place the air purifier under the following aspects Central to achieving th...

Страница 8: ...s the opposite and the air quality is inferior or poor the air purifier switches to a stronger fan speed medium or strong Operating instructions for automatic air sensor operation The air sensor is lo...

Страница 9: ...gain and now press the On Off button permanentlyfor approx 3 seconds The successful reset is signalled by a short acknowledgement tone In addition the flashing of the display field will stop again Cle...

Страница 10: ...ure polish perfume etc in your room In these cases you should refrain from using the automatic air sensor operation Auto Mode It takes too long to neutralise smoke and or odours In general the air pur...

Страница 11: ...uals The warranty begins on the date of sale of the appliance to the end user The guarantee only covers defects that are due to material or manufacturing faults Warranty repairs may only be carried ou...

Страница 12: ...ontains valuable recyclable materials that should be recycled Furthermore the environment or human health should not be polluted by uncontrolled waste disposal Therefore please dispose of old applianc...

Отзывы: