background image

 

Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany 

www.AKTOBIS.de

 

Email: [email protected] 

 
 

5.) Power connection 
 

First connect the supplied power cable properly to the air purifier, then insert the plug into the socket and wait for 
the unit to emit a short acknowledgement tone. 
 
 

6.) Notes on the control panel (touch panel) 

 
The control panel (touch panel) responds best to very short touches of the individual buttons. Longer touches and 
firm presses will cause the air purifier not to respond ! 

 

 

7.) Air sensor operation (automatic mode) 
 

In addition to the air purifier settings as explained previously in point 2, the air purifier also has an automatic air 

sensor mode (automatic mode). Press the button to activate (deactivate) 

and the symbol appears in the fan 

strength display field.

 

 

Please note that the proper air sensor function is only available after approx. one minute ! 

 

If the determined air quality is "good", the air purifier automatically switches to a weak fan speed. If the result is the 
opposite and the air quality is inferior or poor, the air purifier switches to a stronger fan speed (medium or strong). 
 
Operating instructions for automatic air sensor operation: 
The air sensor is located on the side of the unit and reacts to particles in the air and thus always gives only a 
tendency of the air quality. Since it is a tendency (similar to a weather station), this function cannot provide a 100% 
reliable statement about pollutants in the room air or about the entire area of a room.  
Furthermore, stronger operating fluctuations may occur from time to time (jump from good to bad and vice versa), 
as the air sensor probe reacts to different particles in the room and is also exposed to draughts. 
 
Cleaning the air sensor 
We recommend cleaning the air sensor area approx. every 4-6 months to ensure trouble-free operation of the air 
sensor (automatic mode). To do this, take a small soft (damp) cotton rod or something similar (e.g. pipe cleaner) 
and carefully pass it through the air slots of the air sensor area (see the following diagrams). Afterwards, we 
recommend blowing again vigorously into the air slots of the air sensor area. 
 

     

 

 

                           

 

 

 
 

Air slots of the air 

sensor area

 

Содержание WDH-H3

Страница 1: ...uct To ensure that you get a lot of enjoyment from this product here are a few more tips In case of any problems We hope that the unit meets your expectations If despite the greatest possible care the...

Страница 2: ...and solvents Anion exchanger Produces approx 6 8 million anions ions per second which pro actively combat smoke and other dirt particles in the room Air sensor operation automatic mode Automatically m...

Страница 3: ...d wetness Only use the recommended voltage for operating the unit Make sure that the power cable is unfolded untied before connecting it to the socket Make sure that the plug is cleanly and properly c...

Страница 4: ...ing handle Exhaust air Control and display panel Power cable connection Filter compartment door Air intake Control and display panel Exhaust air Filter compartment door Carrying handle Air intake Pre...

Страница 5: ...unit operates at low fan strength Cloud is neutral air quality is polluted unit operates at medium fan speed Cloud is sad air quality is poor unit operates at high fan speed Electrostatic filter block...

Страница 6: ...ilter HEPA activated charcoal filter we recommend that the white HEPA side faces to the right so that the air flows through the HEPA filter first and only then through the activated charcoal filter Fi...

Страница 7: ...HEPA filter combined with the active carbon filter 4 Active carbon filter combined with the HEPA filter 4 The right location Place the air purifier under the following aspects Central to achieving th...

Страница 8: ...s the opposite and the air quality is inferior or poor the air purifier switches to a stronger fan speed medium or strong Operating instructions for automatic air sensor operation The air sensor is lo...

Страница 9: ...gain and now press the On Off button permanentlyfor approx 3 seconds The successful reset is signalled by a short acknowledgement tone In addition the flashing of the display field will stop again Cle...

Страница 10: ...ure polish perfume etc in your room In these cases you should refrain from using the automatic air sensor operation Auto Mode It takes too long to neutralise smoke and or odours In general the air pur...

Страница 11: ...uals The warranty begins on the date of sale of the appliance to the end user The guarantee only covers defects that are due to material or manufacturing faults Warranty repairs may only be carried ou...

Страница 12: ...ontains valuable recyclable materials that should be recycled Furthermore the environment or human health should not be polluted by uncontrolled waste disposal Therefore please dispose of old applianc...

Отзывы: