No bar (

PM value 0-30

)  

= Very good air quality  > Air circulation goes out 

 

 
 

 

3 bars (

PM value 30-75

= Light air pollution 

> Air circulation jumps to level 1 (weak) 

 

 

 

6 bars (

PM value 75-150

= medium air quality 

> Air circulation jumps to level 2 (medium) 

 

 

 

9 bars (

PM value above 150

= Poor air quality> air circulation jumps to level 3 (strong) 

 
 
In addition to the air quality display shown above, a PM value is also shown in the display. You can read at the top 
which air quality category the respective PM value falls into. 

 

Note: The air sensor is located at the front left of the unit and reacts mainly to odours and slightly to particles in the 
air and thus always gives only a tendency of the air quality. Since it is a tendency (similar to a weather station), this 
function cannot provide a 100% reliable statement about pollutants in the room air or about the entire area of a 
room. 
 
From a humidity of approx. 80% r.l. upwards, the air sensor probe may malfunction. In this case, please disable the 
air sensor function (Auto). 
 
Furthermore, stronger operating fluctuations may occur from time to time because the air sensor probe is exposed 
to the draught. 
 
 

Reset of the PM value / air sensor: 

 
After prolonged use of the air sensor, traces of particles will stick to the inductive head of the sensor, which may 
cause the numerical PM display to be abnormal. Only perform a reset if such an abnormal display is likely to occur! 
 
If you find that the numerical PM reading deviates greatly from the normal range, we recommend that you record it 
in the following steps based on the numerical PM reading of the weather forecast in your city. 
 
1.  First blow hard into the "compartment" of the air sensor (front left of the unit). Then open a window for 5 

minutes and place the air purifier near the window (the air sensor records the current ambient data again). 
 

2.  Then press and hold the Settings icon until you hear a click. Now you are automatically in PM correction mode. 

 

3.  Each time you now press the "Settings" key, the PM number of the unit increases by 2ug/m³. Each time you 

press the "Auto" key, you decrease the numerical PM value by 2ug/m³. 
 

4.  If you have adjusted the numerical PM values in the display to the numerical PM values of the weather forecast 

of your city (check on the Internet), please wait 5 seconds and the value will be overwritten and stored. 

 
 
 
 
 
 
 
 
 
 
 

 
 

Содержание 4260196719407

Страница 1: ...o ensure that you get a lot of enjoyment from this product here are a few more tips In case of any problems We hope that the appliance meets your expectations If despite the greatest possible care the...

Страница 2: ...NVENTORY e g in wallpaper carpets upholstery textiles Air sensor optionally switchable Automatically measures the air quality If the determined air quality is good the air purifier automatically switc...

Страница 3: ...recommended voltage for operating the unit Make sure that the power cable is unfolded untied before connecting it to the socket Make sure that the plug is cleanly and properly connected to the socket...

Страница 4: ...lay Remote control receiver Filter Change display Operating buttons Settings Operating mode Speed Air circulation Timing Timer Air quality Display Air circulation Level Operating buttons Reset Reset A...

Страница 5: ...rol The filter compartment diagram 1 Prefilter 2 HEPA ULPA filter 3 Combi filter active carbon catalyst 4 UV lamp 5 Air purifier body 5 4 3 2 1 On Off button Sensor Auto button On Off button Ozone On...

Страница 6: ...ULPA filter 3 Now close the lateral Filter compartment cover again 1 Open the side filter compartment cover Then remove all filters 2 Grasp the UV lamp and turn them by 90 Now it can be pulled out 3...

Страница 7: ...n and automatically starts measuring the air quality There are 4 possible results of the detected air quality see diagram below Please note that the proper air sensor function is only available after...

Страница 8: ...nger operating fluctuations may occur from time to time because the air sensor probe is exposed to the draught Reset of the PM value air sensor After prolonged use of the air sensor traces of particle...

Страница 9: ...e humidity value In addition you can also display the remaining time by briefly pressing the timing button To reset the remaining running time simply press the timing button continuously for approx 3...

Страница 10: ...display as well as via the supplied remote control A button cell CR2032 3V is required to operate the remote control Notes on UV light 1 The UV lamp normally has a service life of approx 4 000 8 000...

Страница 11: ...it can take a considerable time until this inventory releases the odours again 2 Please make sure that the air sensor function Auto is not used when the air purifier is in a draught e g between two o...

Страница 12: ...rect mains voltage or non observance of the assembly instructions Completely or partially dismantled units Conformity The air purifier has been tested and itself and or parts thereof have been manufac...

Отзывы: