Now open the front door and check the cooling fins. If necessary, clean them with a soft hand brush or a
hoover.
Finally, close the front door again. DONE !!!
7. Other notes
Do not expose the compressor to temperatures above 45°C. Please do not do this even if the unit is not switched
on/connected. This could damage the compressor !
The exhaust air of the building dryer is 2°C - 3°C warmer than the supply air (room temperature). This can lead to
greatly increased room temperatures in smaller and well-insulated rooms, this is quite normal.
For an effective and economical dehumidification operation, please close all doors and windows in the operating
room of the building dryer, if possible !
Technical data:
Model name:
WDH-1200HT
Voltage:
220-240V / 50Hz
Normal power consumption:
1,560 W (7.1 A)
Maximum power consumption:
1,840 W (8.3 A)
Dehumidification capacity (optimal):
120 ltr./day
Air circulation:
Approx. 1,000
m3/h
Compressor:
Rotary compressor
Dimension (H/W/D):
1100 x 630 x 470 mm
Weight:
60 kg
Waterproofness:
IPx0
Cooling pressure (max.):
2.5 MPa
Vapour pressure (max.):
1.0 MPa
Refrigerant*:
R454C (1.0 kg)
Range of use:
5°C - 32°C