Instructions for use: 
 

1.  Commissioning 
 

Insert the mains plug properly into the socket. 
 
Make sure that the condensate (water) can drain off unhindered or that the hose connection is properly seated ! 
 
Switch on the unit with the "On/Off switch". 
 
Now set your desired target humidity value between 30% and 90% or select continuous operation. To do this, press 
the "button for lowering the target humidity value" (

▼) or the "button for increasing the target humidity value" (▲), 

as appropriate. Pressing briefly changes the target humidity value by 1% each time. By pressing and holding (1.5 
sec.), the target humidity value can be set by fast forwarding. 
A target value of below 30% humidity is indicated in the display with "CO" and signals that the building dryer is now 
set to continuous operation !!! 
 
After approx. 5 seconds of inactivity, the target humidity value goes out and the currently determined room humidity 
is shown in the display. 
 
Note: The construction dryer has an automatic memory function. In the event of a power failure, this function 
ensures that the building dryer resumes operation where it was previously interrupted. All set values remain stored. 
To protect the compressor, however, its switch-on process is delayed by approx. 3 minutes ! (Compressor light 
flashes during this time). 
 
 

2.  Operating procedure 
 

After the building dryer is properly connected to the socket, the backlight of the display panel lights up. 
 
After switching on the unit (On/Off), the detail display in the control panel lights up automatically. The target 
humidity value is already preset to 60% r.h. by default. 
 
The unit is programmed so that the compressor switches on for dehumidification as soon as the selected target 
humidity value has been exceeded by 3% points (of the current room value). 
The compressor then switches off again automatically as soon as the target humidity value has been undershot by 
3% points. The compressor is then switched on again in the same way, so that there is a tolerance of 6% points 
between the automatic switch-on and switch-off. 
 
After switching off the unit (On/Off), all functions switch off and all displays go out. 
 
 

3.  Operating instructions 
 

If the current humidity is below the target humidity value, the unit does not switch on. 
 
To protect the compressor, the unit should always run for at least 3 minutes or be switched off before you press the 
On/Off switch again! 
 
At cold ambient temperatures or icing in the unit, a sensor automatically controls a defrosting process. This is 
indicated by the following defrost symbol (

in the display field at the top right). Meanwhile, the defrost mode 

automatically controls the air circulation and the compressor operation! 
 
 
 
 
 
 
 
 
 

Содержание 4260196710046

Страница 1: ...improper transport can sometimes occur despite careful instructions on the carton We therefore ask you to leave it upright for at least 1 hour before using it for the first time so that the cooling li...

Страница 2: ...the wall to avoid possible overheating of the unit Do not use in airtight rooms Only qualified personnel or electricians are allowed to open the unit or carry out repairs Make sure that no moisture g...

Страница 3: ...leak cannot be detected immediately by an emerging odour If refrigerant leaks it may ignite or explode especially in poorly ventilated rooms in conjunction with high heat sparks or flames Make sure th...

Страница 4: ...ny www AKTOBIS de Email Info Aktobis de Compressor light Defrost light Description of the unit parts Control element ON OFF SWITCH Operating hours counter Humidity display Increase button the target m...

Страница 5: ...h on process is delayed by approx 3 minutes Compressor light flashes during this time 2 Operating procedure After the building dryer is properly connected to the socket the backlight of the display pa...

Страница 6: ...ter or similar 6 2 Cleaning the air filter screen and the cooling fins The air filter screen at the front of the air intake filters lint hair and coarse construction dust ensuring that this dirt is no...

Страница 7: ...perature This can lead to greatly increased room temperatures in smaller and well insulated rooms this is quite normal For an effective and economical dehumidification operation please close all doors...

Страница 8: ...midity content of the room air and B Heat temperature in the room For safety s sake here is an approximate dehumidification table for DURABLE OPERATION 30 degrees and 80 r h approx 120 litres and at 6...