Aktino AK500 Скачать руководство пользователя страница 3

 

#3 Monitoring 

(see Table 1) 

AktinoView V3 or higher software is used to monitor the 
system.  Load AktinoView V3 software onto the 
maintenance computer per the instructions on the CDROM 
package.  

Provisioning from the CO shelf or unit 

Provisioning can only be done from the CO shelf or unit.  
AktinoView V3 uses the front panel MGMT Ethernet port 
for access to the Aktino unit.  AktinoView V3 should be 
started verify the health of the circuit.  The default user name 
and password is “superuser”.  To provide system security, 
the password for superuser and user accounts should be set 
up with AktinoView V3 Craft Access tabs under the 
Provisioning tab. 
See Table 1 below for provisioning parameters available at 
the CO shelf or unit.  Ethernet and other parameters are 
available via the Provisioning tabs. 

Table 1 Common Provisioning Selections (provisionable 

from the CO shelf or unit only) 

Parameter Values 

MSPAN Rate 

Rate (Kbps) 

# Pairs 

1 to 4 (AK512), 1 to 8 (AK525) 

Individual pairs can be set to UP or 
DOWN in the Pair menu

Line Powering 

Off, -135v, -185v (-185v default) 

Note, line powering is only on 
AK5xxLCP line card and 
AK5xxCUP compact unit

MSPAN SNR Margin 

(MSPAN menu) 

0..18db (5db default) 

Ethernet  Parameters 

Each port’s parameter values can be 
provisioned in the Ethernet tabs

 

#4 System Health Verification 

 
As soon as power is applied to the CO unit (and the RT unit 
if locally powered), the system automatically starts up.  The 
front panel indicators show the status of the system (see 
Figure 5 and Table 2).  If any of the LEDs is not Normal, 
AktinoView V3 can be used to determine the source of the 
problem. 

 

AktinoView V3 main status screen shows an overview of the 
system.  Performance monitoring for Ethernet, MSPAN, and 
Pair is available through the tabs.  Current system alarms 
(see Table 3) are displayed on the main status screen.  Alarm 
history and logs are available through the tabs. 

 
 

Table 2 Front Panel Indicators 

LED Condition 

Function 

STATUS 

Off 

Green 

Red

Power off 

Normal  

Unit in alarm

LOCAL 
PWR 

Off 

Green

Local power is not connected 

Local power is connected

PAIR 
STATUS 

Off 

Solid green 

Flashing green 

Solid red

Pair is disabled 

Pair is up 

Pair is acquiring 

Pair LOS/Open circuit/Short

10/100BaseT 
Act

Off
Green

No data present
Data present

10/100BaseT 
Lk

Off
Green

Ethernet link is down
Ethernet link is up

100B-FX 

1000B-X 

Off 

Green 

SFP is not present 

SFP present and active 

 

 

Table 3 Common Alarms (displayed by AktinoView V3) 

Alarm Fault 

Troubleshooting 

MSPAN LOS

MultiPair Span pairs are down, check pairs

MSPAN Capacity 

MultiPair Span capacity below configured 
rate; increase number of pairs or decrease 
system margin or reduce rate.  Check Pairs 
PM to ensure proper operation.

Pair LOS 

Pair is connected but not receiving signal, 
check Pair PM. 

Pair Open Circuit

Pair is not connected 

 

 

AK500 Ethernet Compact Remote Units  

Document 180-0035-001 R04 