Aktino AK500 Скачать руководство пользователя страница 2

Ground lug (#10) 

AK525RU only 

R4

R3 T4

R2

T2

T3

R5

T5

T8

R7

R6

T6

T7

R8

POWER

3.3A

15V

-

+

R1

T1

12VDC OUT

- +

PAIRS 5-8

PAIRS 1-4

 

 

  

5

6

1

2

7

8

3

4

 

 
 
 

MultiPair Connection 

The MultiPair pluggable connector is used to connect the 
Aktino Compact Remote to the outside plant pairs.  The 
AK512RU uses one four pair connector.  The AK525RU 
uses two four pair connectors.  Insert the tip and rings into 
the connector as shown in Figure 6.  Tighten screws on top 
of the connector.  Insert the connector into the MSPAN plug 
on the back of the Compact Remote Unit (see Figure 4).  The 
Compact Remote Unit MSPAN cable’s shield should 
generally not be connected to ground (leave open).   

 

 

 

Figure 6 Compact Remote Unit MSPAN Pluggable 

Connector 

 

Management Craft Port 

Local management craft access is through the MGMT port 
on the front panel IF remote management is enabled from 
the CO shelf or unit.  
1)

 

Connect an Ethernet cable between the maintenance 
computer and the Compact Remote Unit’s MGMT port.  

2)

 

The Compact Remote Unit has a factory default IP 
address of 192.168.10.2. 

3)

 

Configure the maintenance computer’s IP address to 
192.168.10.3 and Netmask to 255.255.255.0.  Note the 
maintenance computer’s original settings. 

4)

 

Run AktinoView V3 using 192.168.10.2 as the IP 
address for the Aktino unit.  The default user name and 
password is “superuser” (case sensitive). 

5)

 

If desired, the Aktino units can now be monitored with 
AktinoView.  The Compact Remote Unit provides read 
only capability only, system parameters cannot be 
change.  Note, MSPAN must be up to monitor the 
system. 

6)

 

Exit AktinoView V3. 

7)

 

Reconfigure the maintenance computer’s IP address to 
original setting.  

 
 
 
 
 
 
 

Figure 4 Compact Remote Unit Back Panel (AK525RU shown) 

Replaceable Air Filter and 
Fan Assembly 

Local Power input 

Management Craft Port 

12VDC OUT -  See AK5000 Ethernet 
Technical Practice for details 

Figure 5 Compact Remote Unit Front Panel (AK525RU shown) 

R4 

T4 

R8

T8 

R3 

T1 

R1 

T2 

R2 

T3 

R7 

R6 

T7 

T6 

Second connector for 

AK525RU only 

R5 

T5 

AK500 Ethernet Compact Remote Units  

Document 180-0035-001 R04 