ABOUT WARRANTY
Aksa Power Generation will repair or replace, free of charge, any part(s) of the equipment that is defective in materi-
al or workmanship or both. Transportation charges on product submitted for repair or replacement under this
warranty must be borne by purchaser This warranty is effective for the time periods and subject to the conditions
stated below. For warranty service, find the nearest Authorized Service Dealer
DEAR AKSA GENERATING SET OPERATOR,
PLEASETAKE CARE TO THE FOLLOWING ORDERTO PREVENTTHE GENERATING SETWARRANTY TO BECOME INVALID
BEFORETHETERMINATION OF THE WARRANTY PERIOD ANDTO ENSURE TROUBLE-FREE OPERATION OF THE GENERA-
TING SET WITH A LONG LIFE!
• MAINTENANCE AND REPAIR WORKS WILL NOT BE COVERED BY THE WARRANTY CERTIFICATE, INVOICE OR DELIVERY
CERTIFICATE OF THE GENERATING SET IS SUBMITTED.
• THE WARRANTY OF THE GENERATING SET WILL BECOME INVALIDE IN CASE OF ANY INTERVENTION OF ANY PERSON
OTHERTHAN AUTHORIZED AKSA SERVICES OR BY PRIOR WRITTEN APPROVAL FROM AKSA POWER GENERATION ON
THE GENERATING SET FOR ANY REASON.
• CONTROL AND MAINTENANCE WORKS INDICATED IN THE PERIODICAL MAINTENANCE SCHEDULE AND THE OPERA-
TING MANUAL MUST BE CARRIED OUT COMPLETELY AND TIMELY THE FAILURES DUETO INCOMPLETE OR UNTIMELY
MAINTENANCE ARE NOT COVERED BYTHE WARRANTY
• GENERATING SET SHOULD BE MOUNTED AS INDICATED IN THE OPERATING MANUAL OTHERWISE, THE PROBLEMS
WHICH ARE LIKELYTO OCCUR WILL NOT BE COVERED BY THE WARRANTY CUSTOMER IS RESPONSIBLE FORTHE FAILU-
RES WHICH ARE LIKELYTO OCCUR IN CASE THATTHE DIESEL OIL USED CONTAINS DIRT OR WATER
• THE OILTYPE INDICATED IN THE OPERATING MANUAL SHOULD BE USED IN THE ENGINE OTHERWISE, THE FAILURES
WHICH ARE LIKELYTO OCCUR WILL NOT BE COVERED BYTHE WARRANTY
• BATTERIESWILL NOT BE COVERED BYTHE WARRANTY IFTHEYARE SUBJECTED TO BREAKAGE, EXCESSIVE ACID FILL OR
HARDNING BY LEAVING UNCHARGED.
• GENERATING SETS, NEVER START OR STOPTHE DIESEL ENGINE WHENTHE GENERATING SET IS UNDER LOAD. ENGINE
SHOULD BE STARTED AND STOPPED AFTER LOAD IS DISCONNECTED ANDTHE GENERATING SET IS AT IDLE CONDI-
TION. OTHERWISETHEVALVES CAN BE SEIZEDTHE VOLTAGE REGULATORTRANSFORMERAND DIODES CAN BE
BROKEN DOWN.THESE CONDITIONS ARE NOT COVERED WARRANTY
• OUR COMPANY DOES NOTTAKETHE RESPONSIBILITY OFTHE DAMAGES ON THE MAINS SUPPLY CONTACTOR OFTHE
AUTOMATIC GENERATING SETS DUETO OVERCURRENT LOW OR HIGH VOLTAGE.
• NEVER REMOVETHE BATTERYTERMINALS WHILETHE GENERATING SET IS IN USE. EVEN A MOMENT OF DISCONNEC-
TION CAN CAUSE A DAMAGE ON THE ELECTRONIC CLOSING RELAY OF THE CHARGE ALTERNATO THIS CONDITION IS
NOT COVERED BY THE WARRANTY
• FAILURES DUETO OVERLOAD AND UNBALANCED LOAD IN EXCESS OFTHE GENERATING SET POWER (SUCH AS ALTER-
NATOR AND CONTACTOR FAILURES) ARE NOT COVERED BYTHE WARRANTY
• WHENTHE MANUAL GENERATING SET IS STARTED UR IT SHOULD BE WARMED BY OPERATING AT IDLE FOR 5 MINU-
TES. WHEN STOPPINGTHE DIESEL ENGINE, IT SHOULD BE UNLOADED AND THEN CONTINUED TO BE OPERATED FOR
COLOLING FOR 5 MINUTES BEFORE STOPPING. OTHERWISE PROBLEMS WHICH ARE LIKELYTO OCCUR WILL NOT BE
COVERED BYTHE WARRANTY.
• OPERATIONAL WARNING ! : IF ONLY SINGLE PHASE LOAD OPERATION REQUIRED FOR THE 3 PHASE GENERATOR SETS;
MAKE SURE LOAD CAPACITY ON THE SINGLE PHASE DOES NOT EXCEED %30 OF THE NOMINAL POWER OF THE GENE-
RATOR SET. OTHERWISE IT WILL DAMAGE THE GENERATOR SET PERMANENTLY AND THE DAMAGE WILL NOT COVE-
RED UNDER MANUFACTURER'S WARRANTIES.